Vt300e Handheld Vital Sign Monitor Portable Mini Multi Parameter Monitor for Human or Veterinary

Min.Order: 1
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ 265 ~ 350

Description
SPO2+ECG+NIBP+TEMP+PR
Model:VT300V

Features

 

ECG:3/5 Leads,3 waves

 

Accurate measurement in 0.05% Low perfusion Index,the word leading production in the movement environment

 

Provide the parameter of PI( Perfusion Index 0.05%-20%)

 

Accurate measurement in all kind of extreme environment measurement such as neonatal and shock patients

 

NIBP adopt SAWAA(Self-Adaptive-Waveform-Amplitude -Adjust)algorithm and SAFD(Self-Adaptive-Fast-Deflation)algorithm

 

Easy operation by 4'' color TFT

Up to 100 users ID switch

 

Multiple vital signs measurement parameters for collocation optional

3/5 Leads ECG,NIBP,Spo2,Temp

NIBP,Spo2,Temp,Co2

 

two measurements mode:Spot,Monitoring

 

Data storage capabilities, support for historical data view and trend chart back to see

In monitoring mode, can continuously record 48 hours of measurement data

In spot mode,100 users ID, each user can store 200sets data

 

Support audio and visual alarm,support to set alarm upper and lower limit values

 

Lithium ion battery power supply

 

Performance  Specifications

 

 

ECG

Lead       7 lead (R, L, F, N, C1 or RA, LA, LL, RL, V1)

Lead mode       I, II, III, aVR, aVL, aVF, V1, CAL

Wave     3 waves

Gain selection 0.25V/mV, ´0.5V/mV, ´1V/mV, ´2V/mV

 

 

Heart  Rate:

 

Range

Adult 15 ~ 300 bpm

Neo/Ped     15 ~ 350 bpm

Accuracy ±1% or ±1bpm Bigger

Resolution     1 bpm

Sensitivity    > 200 uV (peak to peak)

 

Bandwidth

Diagnositic  0.05 ~100 Hz

Monitor      0.5 ~ 40Hz

Surgery         1 ~ 20 Hz

Stronger Filter  5 ~ 20Hz

 

Oxygen Saturation(%Spo2)

Measurement Range: Spo2: 0~100%   

                   PR:0-254bpm

Perfusion Index:    0.025%-20%

  Accuracy range:     SpO2:70%-100%

          PR:30-254bpm

Perfusion Index: 0.05%-20%

Measurement accuracy

SpO2 saturation:

Adult (including pediatric ) ±2bpm(70%--100%)     PR:   ±3bpm           Neonate  ±3bpm  not defined(<70%)              PR:   ±3bpm           On motion condition ±5bpm

 

Temperature

   Measurement  range: 25 - 45°C

   Resolution:            0.1°C

   Accuracy:         ±0.1°C

Power Type: Lithium ion battery

Operation time: 8 hours for normal operation

Temperature: Operating: 0ºC~45ºC  Starage/ Transportation: -20ºC~65ºC

Humidity:  Operating: 15% to 90% noncondensing  Storage:  0% to 95% noncondensing

Altitude: Operating Altitude: Up to 5000 meters

SIZE:  Dimension 146mm*67mm*30mm  Weight  250g

 

 

Display: 4' '  color TFT            Resolution: 320*480

Indicator: Alarm indicator,Power indicator 

Trace:   1 plethysmogram waveform,ECG wave

Alarm:   Probe off, low power         Modes:   Visual and Audio

Application:  Neonatal,pediatric and adult patients

 

NIBP

The wider NIDP measurement range                                         

Adult Mode

SYS  40 ~270 (mmHg)

MEAN    20 ~230(mmHg)

DIA      10 ~210 (mmHg)

 Pediatric Mode

 SYS  40 ~ 200 (mmHg)

MEAN  10 ~ 150 (mmHg)

 DIA  20 ~ 165 (mmHg)

 Neonatal Mode

SYS  40 ~ 135 (mmHg)

MEAN  20 ~ 105 (mmHg)

  DIA  10 ~ 95 (mmHg)

Pulse rate range:40~240bpm

NIBP measurement accuracy3mmHg

Pulse rate measurement accuracy:<=2% (>=100 BPM) or 2 beats/min (<100 BPM)

 

Independent  software protection pressure

Adult        300mmHg

PED         240mmHg

NEO         150mmHg

 

Independent  hardware protection pressure

Adult        320--330mmHg

PED         265--275mmHg

NEO         160--165mmHg

 


 