Smart Monitoring System
Technical specifications
Model Name | RHI-3K-48ES-5G | RHI-3.6K-48ES-5G | RHI-4.6K-48ES-5G | RHI-5K-48ES-5G | RHI-6K-48ES-5G | ||
Input DC (PV side) | |||||||
Recommended max. PV power | 7 kW | 7 kW | 8 kW | 8 kW | 8 kW | ||
Max. input voltage | 600 V | ||||||
Rated voltage | 330 V | ||||||
Start-up voltage | 120 V | ||||||
MPPT voltage range | 90-520 V | ||||||
Max. input current | 11 A / 11 A | ||||||
Max. short circuit current | 17.2 A / 17.2 A | ||||||
MPPT number/Max. input strings number | 2/2 | ||||||
Battery | |||||||
Battery type | Li-ion / Lead-acid | ||||||
Battery voltage range | 42 - 58 V | ||||||
Battery capacity | 50 - 2000 Ah | ||||||
Max. charge / discharge power | 3 kW | 5 kW | |||||
Max. charge / discharge current | 62.5 A | 100 A | |||||
Communication | CAN | ||||||
Output AC (Back-up) | |||||||
Rated output power | 3 kW | 5 kW | |||||
Max. apparent output power | 4 kVA | 6 kVA | |||||
Back-up switch time | <20 ms | ||||||
Rated output voltage | 1/N/PE, 220 V / 230 V | ||||||
Rated frequency | 50 Hz / 60 Hz | ||||||
Rated output current | 13.6 A / 13 A | 22.7 A / 22 A | |||||
THDv (@linear load) | <2% | ||||||
Input AC (Grid side) | |||||||
Input voltage range | 184-264 V | ||||||
Max. input current | 26.1 A | ||||||
Frequency range | 45-55 Hz / 55-65 Hz | ||||||
Output AC (Grid side) | |||||||
Rated output power | 3 kW | 3.6 kW | 4.6 kW | 5 kW | 6 kW | ||
Max. apparent output power | 3.3 kVA | 4 kVA | 4.6 kVA | 5.5 kVA | 6 kVA | ||
Operation phase | 1/N/PE | ||||||
Rated grid voltage | 220 V / 230 V | ||||||
Rated grid frequency | 50 Hz / 60 Hz | ||||||
Rated grid output current | 13.6 A / 13 A | 16.3 A / 15.7 A | 20.9 A / 20 A | 22.7 A / 21.7 A | 27.2 A / 26.1 A | ||
Max. output current | 15.7 A | 17.3 A | 23 A | 23.9 A | 26.1 A | ||
Power Factor | >0.99 (0.8 leading - 0.8 lagging) | ||||||
THDi | <2% | ||||||
Efficiency | |||||||
Max. efficiency | >97.5% | ||||||
EU efficiency | >96.8% | ||||||
Protection | |||||||
DC reverse-polarity protection | Yes | ||||||
Short circuit protection | Yes | ||||||
Output over current protection | Yes | ||||||
Surge protection | DC Type II / AC Type II | ||||||
Ground fault monitoring | Yes | ||||||
Integrated AFCI (DC arc-fault circuit protection) | Yes (1) | ||||||
Protection class/Over voltage category | I/II | ||||||
General Data | |||||||
Dimensions (W*H*D) | 333*505*249 mm | ||||||
Weight | 18.3 kg | ||||||
Topology | High frequency isolation (for battery) | ||||||
Operating ambient temperature range | -25 ~ +60°C | ||||||
Ingress protection | IP65 | ||||||
Cooling concept | Natural convection | ||||||
Max. operation altitude | 2000 m | ||||||
Grid connection standard | G98 or G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 / UNE 206006 / UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA | ||||||
Safety/EMC standard | IEC/EN 62109-1/-2, EN 61000-6-2/-3 | ||||||
Features | |||||||
DC connection | MC4 connector | ||||||
AC connection | Quick connection plug | ||||||
Display | 7.0"LCD color screen display | ||||||
Communication | RS485, Optional: Wi-Fi, GPRS |