6SL3120-1te23-0444 PLC Control CPU

Min.Order: 1
Product origin: Wenzhou, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 1000 ~ 1850

Description
Product Description
SIS-12/630(1250)-20(25)-31.5 solid insulated ring network switchgear is a new generation environmentally friendly composite insulated ring network cabinet developed by ourcompany. 
Mainly composed of three components,V unit (circuit breaker unit), C unit (load switch unit), F unit (combined with electrical unit),each unit can be used alone or freely expandable, and its structure is divided into intelligent control instruments Room,operating mechanism and primary part, the instrument room can be equipped with microcomputer protection (controller), the primary part adopts APG automatic gel process,the isolating switch and arc extinguishing chamber are completely sealed in epoxy resin,and there are use specially joints and bus bars to connect.The arc extinguishing chamber adopts special copper-chromium contact material, R-type longitudinal magnetic field contact,and a complete one-time sealing process. The interrupting short-circuit current capabilityand stability,electrical life, temperature rise and insulation level of the arc extinguishingchamber are all higher than before The arc extinguishing chamber (copper-aluminumcontact material, cup-shaped longitudinal magnetic field contact structure, and incompleteone-time sealing process) has been significantly improved.The operating mechanismadopts a spring-operated mechanism that cooperates with the switch, that is, the isolationswitch and the main switch spring-operated mechanism are integrated, which canfacilitate interlocking, and has fewer mechanical parts, reduces unnecessary transmissionlinks, and has high reliability.And can realize electric operation according to user needs.Solid insulation fully enclosed switchgear: it uses solid insulation material as the maininsulation medium and conductive connection, isolation switch, grounding switch, mainbus bar, branch bus bar and other main conductive loops, single or combined, and thencovered and packaged with solid insulation medium into one or more A fully insulated andfully sealed module with certain functions that can be combined or expanded again


 

1.IEC62271-1-2007  "High Voltage switchgear and Control Equipment, Part-General Specification"
2.GB1985 2004  "High Voltage AC Isolating Switch and Grounding Switch" 
3.IEC620071-200-2003  "1-52KV AC Metal-enclosed Switchgear and Control Equipment"
4.GB3804 2004 "3.6KV ~ 40 5KV High Voltage AC Load Switch" 
5.GB3906-2006 "3.6~ 40.5KV AC Metal-enclosed switchgear and control equipment"
6.DL/T404-2007 "3 6KV-40.5KV AC metal enclosed Switchgear and Control Equipment
7.DL/T593006 "Standard Common Technical Conditions for High Voltage Sswitchgear control equipment.
8.GB/T11022-1999 "Common technical conditions for high voltage switchgear and  Control Equipment Standrand.
9.GB1984-2003 "High Voltage AC Circuit Breaker" 
10.Q/GDW7302012 "12KV solid Insulated ring main unit technical conditions" 
 
Detailed Photos
 



 

Product Parameters
Use Enviroment    
Altitude5000 meters   
     
Adaptto environmental temperature-50°C ~+70°C   
     
Air relative humidity95% (+25°C)   
     
Ground inclination5°C   
     
Earthquake intensiry Nomore han&degrees   
     
Switchgear Technical Paramaters       
Items    
Rated Voltage  Kv12
Rated Frequency  Hz50
Rated Current  A630 1250
Rated Insulation levelPower frequency
withstand voltage
FractureKv48
AlternateKv42
Relative to groundKv42
Lighting impulse
withstand voltage
FractureKv85
AlternateKv75
Relative to groundKv75
Rated short-circuit breaking current(1s)  Ka25  31.5
Rated short-time withstand current(4s)  Ka25  31.5
Rated peak-withstanddd current (1p)  Ka63  80
Rated short-circuit making current(peak value)(1ma)  Ka63  80
Shell protection gradde  IP4X 
Operation mode  Spring energy storage type 
     
Circuit Breaker Technical Parameters    
Items UnitDataData
Rated Voltage Kv12 
Rated Frequency Hz50 
Rated insulation level1min Power frequency withstand voltageKv42 
Lighting impulse withstand voltageKv75 
Rated Current A6301250
Rated short-circuit breaking current(1s) Ka20 2531.5
Rated short-circuit making current(peak value)(1ma) Ka50 63 80
Rated peak withstand current(4s) Ka50 63 80
Rated short-time withstand current(effective value) Ka20 2531.5
Rated short-time breaking current breaking times times3030
Rated short-circuit breaking duration s4 
Rated operation sequenceAutomatic reclosing Opening-0.3s-closing opening-180s-closing opening
(rated short-circuit breaking current is below 31.5)
Non-automatic reclosing Opening-180s-closing opening -180s-closing opening
(rated short-circuit breaking current is below 40ka)
Mechanical life times10000 
     
Grounding switch  Technical Parameters    
Items UnitDataData
Rated Voltage Kv12 
Rated current  6301250
Rated short-time withstand current(effective value) Hz2531.5
Rated peak withstand current(peak value) Kv6380
1 min power frequency withstand voltageBetween phase andto groundKv42 
Isolation fracture 48 
Rated lighting impulse withstand voltageBetween phase andto groundA75 
Isolation fractureKa85 
Mechanical life of isolating switch(open-close) Ka3000 
Mechanical life of earthing switch(min-earthing) Ka3000 
     
Grounding switch  Technical Parameters    
Items UnitDataData
Rated Voltage Kv12 
Rated current KA6301250
Rated short-time withstand current(effective value) Hz2531.5
Rated peak withstand current(peak value) Kv6380
1 min power frequency withstand voltageBetween phase andto groundKv42 
Isolation fracture 48 
Rated lighting impulse withstand voltageBetween phase andto groundA75 
Isolation fractureKa85 
Mechanical life of isolating switch(open-close) Ka3000 
Mechanical life of earthing switch(min-earthing) Ka3000 
     
Break Technical Parameters    
Items UnitDataData
Type of interrupter vacuum  Vacuum 
Rated current A6301250
Rated short-circuit breaking currentAC component effective valuekv25 
Number of breaking timestimes30 
Rated operating sequence  0-0.3S-CO-100S-CO 
Rated short-time withstand current(duration) ka/s25/4, 
Rated peak withstand current  ka63 
Rated short-circuit making current  ka63 
Average opening andd closing speed Opening speedOpening speedm/s1.4+0.2 
Closing speed0.8+0.2 
Closing bounce time ms231.5
Opening contact rebound amplitude mm280
Closing time ms30-70 
Opening time ms20-50 
Three-phase different period ms2 
Different phase grounding fault breaking testTest currentKa21.7 
Test voltagekv12 
Capacitive current breaking testTest currentKa25 
Test voltagekv12 
Main circuit resistance 120 
Mechnical life times times10000 
     
Combination Appliances Parameters    
Item UnitData 
Type of interrupter AVacuum 
Rated current ka125 
Rated short-circuit breaking current A31.5 
Rated transfer current A3150 
     
Isolation Switch Paratmeters    
Item UnitData 
Rated current A630 1250 
Main circuit resistance 2 
Rated short-circuit withstand current ka/s25/4. 
Rated peak withstand current  KA63 
Mechanical life times3000 
     
Eearthing Switch Paratmeters    
Item UnitData 
Rated short-circuit withstand current ka/s25/4. 
Rated peak withstand current  A63 
Mechanical life times3000 
     
Fuse tube Paratmeters    

Fuse and transformer selection table      
It has the following salient features:
1.Combined with vacuum load switch, the transfer current can reach 3150A;
2.Full range of distribution transformer protection, the maximum melting core current can reach 200A;
3.Double grounding pro tection, reliable five-proof interlock, higher safety performance:
4.Select standard fuses, convenient for users to prepare spare parts

Application field    
1.Low temperature and cold area: No SF6 gas application, no need to consider the low temperature operation of SF6 gas, and it can operate normallyat -45° C.  
2.Plateau area: There is no need to consider the infuence of plateau atmospheric pressure on insulation performance.   
3.Areas with strong wind and sand: The safety protection grade of the solid insulation ring main unit is IP67,
and the control circuit room adopts special treatment to ensure long-term operation in areas with strong wind and sand.
4.Coastal wet areas: epoxy resin sealing, moisture resistance, salt spray corrosion resistance, to ensure long term use in coastal areas.   
5.Areas with high environmental protection requirements: The impact of SF6 gas on atmospheric warming has attracted great attention.
The solid ring network cabinet has cancelled SF6 gas, and there is no pollution or harm to the environment and people.
6.In the smart grid: Since the main switch can be electric, the optional smart controller developed by our company can remotely control, remotely measure and remotely communicate the switchgear and and facilitate centralized control.substation site, which can perform decentralized control
     
     
Packaging & Shipping

 

Our Advantages

After Sales Service

 

Product Tag: