Ethernet PLC Control Siemens CPU Module

Min.Order: 1
Product origin: Wenzhou, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 1000 ~ 1850

Description
sotck
model
6SL3136-7TE25-5449
6S1 3120-2T621-0443
6SL3120-2TE21-0444
6L3120-1TE21-0444
6SL3120-1TE23-0443
6SL3120-1TE23-0444
6SL3126-2TE21-8443
6SL3130-7TE21-6A43
6SL3126-1TE21-8AA3
6SL3120-2TE13-0AA4
6SL3120-1TE13-0AA3
6SL3126-2TE13-0AA3
6SL3126-2TE13-0AA4
6SL3120-1TE26-0AA3
6FC5372-0AA30-0AA1
6SL3055-0AA00-3PA1
6FC5303-0AF35-0CA0
6SL3040-1NC00-0AA0
6SL3055-0AA00-5BA3
6SL3040-0MA00-0AA1
6SL3040-1MA00-0AA0
6FC5210-0DF52-3AA0
6FC5203-0AF00-0AA1
6FC5203-0AF04-1BA1
6FC5203-0AF05-0AB0
6FC500-AA11-1AA0
6FC5311-0AA00-0AA0
6FC5370-1AM00-0CA0
6SL3130-7TE31-2AA3
6SL3100-0BE21-6AB0
6SL3100-0BE25-5AB0
6SL3100-0BE28-0AB0
6SL3100-0BE31-2AB0
6SL3120-1TE31-3AA3
6SL3130-7TE28-0AA3
6XV1830-0EH10 300
6ES7313-5BG04-0AB0
6ES7315-2EH14-0AB0
6ES7321-1BL00-0AA0 3
6ES7331-7PF01-0AB0
6ES7307-1BA01-0AA0
7MH4950-2AA01
6ES7314-6EH04-0AB0
6ES7321-1BH02-0AA0 
6ES7221-3BD30-0XB0
6ES7211-1BE40-0XB0
6ES7214-1HG40-0XB0
6ES7241-1AH32-0XB0
6ES7307-1EA01-0AA0
6ES7 132-4BF00-0AA0
6ES7 132-4BD02-0AA0
6ES7 132-4BD32-0AA0
6ES7 132-4HB01-0AA0
6ES7 134-4GB11-0AB0
6ES7 134-4GB01-0AB0
6ES7 134-4JB51-0AB0
6ES7 134-4GB11-0AB0
6ES7 138-4DA04-0AB0
6ES7 138-4AA11-0AB0
6ES7 138-4CA01-0AA0
6ES7 138-4AA01-0AA0
6ES7 135-4GB01-0AB0
7MH4910-0AA01
6ES7 151-1BA02-0AB0
6ES7 151-7AA21-0AB0
6ES7 151-7AA21-0AB0
6ES7 407-0KA02-0AA0
6ES7 416-2XN05-0AB0
6ES7 443-1EX30-0XE0
6ES7 421-1BL01-0AA0
6ES7 421-7BH01-0AB0
6ES7 422-1BL00-0AB0
6ES7 431-1KF10-0AB0
7MH4950-1AA01
6ES7231-4HA30-0XB0
6ES7153-1AA03-0XB0
6ES7215-1HG40-0XB0 
6ES7223-1PH32-0XB0
6ES7331-7NF00-0AB0
3RK1901-1MX02 
3RU2116-0EB1
6GK5324-0GG10-1AR2 
6GK1162-3AA00
6GK5992-2GA00-8AA0
6GK5992-2AS00-8AA0
6GK5992-1AM00-8AA0
7MF4900-1AA02-2B
7MF4033-1DY00-1AB6
6AV2124-0GC01-0AX0
6AV2124-0MC01-0AX0
6AV2181-8XP00-0AX0
6AV6671-8XA00-0AX0
6ES7131-6BH01-0BA0
6ES7132-6BH01-0BA0
6ES7134-6GF00-0AA1
6ES7134-6TD00-0CA1
6ES7135-6HD00-0BA1
6ES7155-6AA01-0BN0
6ES7155-6AU01-0BN0
6ES7193-6AR00-0AA0
6ES7193-6BP00-0BA0
6ES7193-6BP00-0DA0
6ES7212-1HE40-0XB0
6ES7214-1BG40-0XB0
6ES7215-1AG40-0XB0
6RY1702-0BA01 
 6RY1802-0CA11 
6RY1801-0AA04
6RY1700-0AA17 
6ES7532-5HF00-0AB0 
6ES7531-7PF00-0AB0 
6EP1334-2BA20 
6GK7542-5FX00-0XE0 
6ES7545-5DA00-0AB0 
6ES7193-6BP00-0DA0 
6ES7135-6HD00-0BA1 
6AV2181-4GB00-0AX0
6ES7132-6BH01-0BA0 
3VA9200-0WC00 
 6RA8095-4GS22-0AA0-Z G00
6RY1702-0CA18 
6ES7660-3HD41-2DA0
6RY1802-0CA10
6RY1700-0BA01 
3SE5250-0BC05
3SE5413-0CD21-1EA2
6ES7222-1BH32-0XB0
6ES7223-1BH32-0XB0
6ES7505-0RB00-0AB0
6ES7510-1DJ01-0AB0
6ES7516-3AN02-0AB0
6ES7545-5DA00-0AB0
6ES7590-1AB60-0AA0
6ES7590-1AC40-0AA0
6ES7655-5DX60-1BB0
6ES7954-8LE03-0AA0
6ES7954-8LL03-0AA0
6ES7972-0BA12-0XA0
6GK1503-3CC00
6GK5206-2BS00-2AC2
6GK5308-2FL10-2AA3
6GK5308-2FM10-2AA3
6GK5992-1AM00-8AA0
6GK7243-1BX30-0XE0
6GK7243-5DX30-0XE0
6XV1830-0EH10
6AV6881-0AV21-0AA0
6ES7193-6BP00-0DA0 
6ES7134-6GF00-0AA1 
6ES7193-6AR00-0AA0 
6ES7137-6AA01-0BA0 
6ES7512-1DK01-0AB0 
6GK5108-0BA00-2AC2 
6ES7512-1DK01-0AB0 
6ES7137-6AA01-0BA0 
6ES7153-2BA10-0XB0 
6ES7321-1BL00-0AA0 


 
SIS-12/630(1250)-20(25)-31.5 solid insulated ring network switchgear is a new generation environmentally friendly composite insulated ring network cabinet developed by ourcompany. 
Mainly composed of three components,V unit (circuit breaker unit), C unit (load switch unit), F unit (combined with electrical unit),each unit can be used alone or freely expandable, and its structure is divided into intelligent control instruments Room,operating mechanism and primary part, the instrument room can be equipped with microcomputer protection (controller), the primary part adopts APG automatic gel process,the isolating switch and arc extinguishing chamber are completely sealed in epoxy resin,and there are use specially joints and bus bars to connect.The arc extinguishing chamber adopts special copper-chromium contact material, R-type longitudinal magnetic field contact,and a complete one-time sealing process. The interrupting short-circuit current capabilityand stability,electrical life, temperature rise and insulation level of the arc extinguishingchamber are all higher than before The arc extinguishing chamber (copper-aluminumcontact material, cup-shaped longitudinal magnetic field contact structure, and incompleteone-time sealing process) has been significantly improved.The operating mechanismadopts a spring-operated mechanism that cooperates with the switch, that is, the isolationswitch and the main switch spring-operated mechanism are integrated, which canfacilitate interlocking, and has fewer mechanical parts, reduces unnecessary transmissionlinks, and has high reliability.And can realize electric operation according to user needs.Solid insulation fully enclosed switchgear: it uses solid insulation material as the maininsulation medium and conductive connection, isolation switch, grounding switch, mainbus bar, branch bus bar and other main conductive loops, single or combined, and thencovered and packaged with solid insulation medium into one or more A fully insulated andfully sealed module with certain functions that can be combined or expanded again


 

1.IEC62271-1-2007  "High Voltage switchgear and Control Equipment, Part-General Specification"
2.GB1985 2004  "High Voltage AC Isolating Switch and Grounding Switch" 
3.IEC620071-200-2003  "1-52KV AC Metal-enclosed Switchgear and Control Equipment"
4.GB3804 2004 "3.6KV ~ 40 5KV High Voltage AC Load Switch" 
5.GB3906-2006 "3.6~ 40.5KV AC Metal-enclosed switchgear and control equipment"
6.DL/T404-2007 "3 6KV-40.5KV AC metal enclosed Switchgear and Control Equipment
7.DL/T593006 "Standard Common Technical Conditions for High Voltage Sswitchgear control equipment.
8.GB/T11022-1999 "Common technical conditions for high voltage switchgear and  Control Equipment Standrand.
9.GB1984-2003 "High Voltage AC Circuit Breaker" 
10.Q/GDW7302012 "12KV solid Insulated ring main unit technical conditions" 
 
Detailed Photos
 



 

Product Parameters
Use Enviroment    
Altitude5000 meters   
     
Adaptto environmental temperature-50°C ~+70°C   
     
Air relative humidity95% (+25°C)   
     
Ground inclination5°C   
     
Earthquake intensiry Nomore han&degrees   
     
Switchgear Technical Paramaters       
Items    
Rated Voltage  Kv12
Rated Frequency  Hz50
Rated Current  A630 1250
Rated Insulation levelPower frequency
withstand voltage
FractureKv48
AlternateKv42
Relative to groundKv42
Lighting impulse
withstand voltage
FractureKv85
AlternateKv75
Relative to groundKv75
Rated short-circuit breaking current(1s)  Ka25  31.5
Rated short-time withstand current(4s)  Ka25  31.5
Rated peak-withstanddd current (1p)  Ka63  80
Rated short-circuit making current(peak value)(1ma)  Ka63  80
Shell protection gradde  IP4X 
Operation mode  Spring energy storage type 
     
Circuit Breaker Technical Parameters    
Items UnitDataData
Rated Voltage Kv12 
Rated Frequency Hz50 
Rated insulation level1min Power frequency withstand voltageKv42 
Lighting impulse withstand voltageKv75 
Rated Current A6301250
Rated short-circuit breaking current(1s) Ka20 2531.5
Rated short-circuit making current(peak value)(1ma) Ka50 63 80
Rated peak withstand current(4s) Ka50 63 80
Rated short-time withstand current(effective value) Ka20 2531.5
Rated short-time breaking current breaking times times3030
Rated short-circuit breaking duration s4 
Rated operation sequenceAutomatic reclosing Opening-0.3s-closing opening-180s-closing opening
(rated short-circuit breaking current is below 31.5)
Non-automatic reclosing Opening-180s-closing opening -180s-closing opening
(rated short-circuit breaking current is below 40ka)
Mechanical life times10000 
     
Grounding switch  Technical Parameters    
Items UnitDataData
Rated Voltage Kv12 
Rated current  6301250
Rated short-time withstand current(effective value) Hz2531.5
Rated peak withstand current(peak value) Kv6380
1 min power frequency withstand voltageBetween phase andto groundKv42 
Isolation fracture 48 
Rated lighting impulse withstand voltageBetween phase andto groundA75 
Isolation fractureKa85 
Mechanical life of isolating switch(open-close) Ka3000 
Mechanical life of earthing switch(min-earthing) Ka3000 
     
Grounding switch  Technical Parameters    
Items UnitDataData
Rated Voltage Kv12 
Rated current KA6301250
Rated short-time withstand current(effective value) Hz2531.5
Rated peak withstand current(peak value) Kv6380
1 min power frequency withstand voltageBetween phase andto groundKv42 
Isolation fracture 48 
Rated lighting impulse withstand voltageBetween phase andto groundA75 
Isolation fractureKa85 
Mechanical life of isolating switch(open-close) Ka3000 
Mechanical life of earthing switch(min-earthing) Ka3000 
     
Break Technical Parameters    
Items UnitDataData
Type of interrupter vacuum  Vacuum 
Rated current A6301250
Rated short-circuit breaking currentAC component effective valuekv25 
Number of breaking timestimes30 
Rated operating sequence  0-0.3S-CO-100S-CO 
Rated short-time withstand current(duration) ka/s25/4, 
Rated peak withstand current  ka63 
Rated short-circuit making current  ka63 
Average opening andd closing speed Opening speedOpening speedm/s1.4+0.2 
Closing speed0.8+0.2 
Closing bounce time ms231.5
Opening contact rebound amplitude mm280
Closing time ms30-70 
Opening time ms20-50 
Three-phase different period ms2 
Different phase grounding fault breaking testTest currentKa21.7 
Test voltagekv12 
Capacitive current breaking testTest currentKa25 
Test voltagekv12 
Main circuit resistance 120 
Mechnical life times times10000 
     
Combination Appliances Parameters    
Item UnitData 
Type of interrupter AVacuum 
Rated current ka125 
Rated short-circuit breaking current A31.5 
Rated transfer current A3150 
     
Isolation Switch Paratmeters    
Item UnitData 
Rated current A630 1250 
Main circuit resistance 2 
Rated short-circuit withstand current ka/s25/4. 
Rated peak withstand current  KA63 
Mechanical life times3000 
     
Eearthing Switch Paratmeters    
Item UnitData 
Rated short-circuit withstand current ka/s25/4. 
Rated peak withstand current  A63 
Mechanical life times3000 
     
Fuse tube Paratmeters    

Fuse and transformer selection table      
It has the following salient features:
1.Combined with vacuum load switch, the transfer current can reach 3150A;
2.Full range of distribution transformer protection, the maximum melting core current can reach 200A;
3.Double grounding pro tection, reliable five-proof interlock, higher safety performance:
4.Select standard fuses, convenient for users to prepare spare parts

Application field    
1.Low temperature and cold area: No SF6 gas application, no need to consider the low temperature operation of SF6 gas, and it can operate normallyat -45° C.  
2.Plateau area: There is no need to consider the infuence of plateau atmospheric pressure on insulation performance.   
3.Areas with strong wind and sand: The safety protection grade of the solid insulation ring main unit is IP67,
and the control circuit room adopts special treatment to ensure long-term operation in areas with strong wind and sand.
4.Coastal wet areas: epoxy resin sealing, moisture resistance, salt spray corrosion resistance, to ensure long term use in coastal areas.   
5.Areas with high environmental protection requirements: The impact of SF6 gas on atmospheric warming has attracted great attention.
The solid ring network cabinet has cancelled SF6 gas, and there is no pollution or harm to the environment and people.
6.In the smart grid: Since the main switch can be electric, the optional smart controller developed by our company can remotely control, remotely measure and remotely communicate the switchgear and and facilitate centralized control.substation site, which can perform decentralized control
     
     
Packaging & Shipping

 

Our Advantages

After Sales Service

 

Scroll to Top