Eo Ethylene Oxide Gas Sterilizer for Disposable Syringe, Infusion Set, Surgical Gown

Min.Order: 1
Product origin: Suzhou, Jiangsu, China
Infringement complaint: complaintComplaint
US$ 30000 ~ 70000

Description

Eo Ethylene Oxide Gas Sterilizer for Disposable Syringe,Infusion Set,Surgical Gown

Description:
Now, disposable syringe manufacturers use ethylene oxide sterilization syringes, and eo sterilization is used more widely.

ethylene oxide sterilization of syringes has some advantages.  Ethylene oxide sterilization kills all microorganisms, including bacterial spores.  If the syringe has been sterilized, you can wrap the sterile syringe to keep the syringe sterile.  Ethylene oxide does not etch plastic, metal and rubber materials.  Ethylene oxide can penetrate irregular products.

Features:
1.  The operation process is controlled by PLC+ industrial computer.
2.  Sterilization time is generally 8 ~ 12h.
3.  The device has the following alarm functions: (a) sensor fault alarm (b) dose alarm (c) overpressure alarm (d) high temperature alarm (e) opening and closing alarm: audible alarm when opening and closing.
4.  Single machine can complete the whole sterilization process independently, and the sterilization effect is reliable
5.  Applicable to hospital operating rooms, scientific research units, chemical laboratories, archives

How to use eto sterilization?
Prerequisite: Expose the product to a warm, humid environment for at least 12 hours (70%RH, 55 ° C) to ensure that the product is at a uniform temperature and humidity.

Exposure: Vacuum and introduction of EtO gas.  The product is usually exposed for 4-8 hours.  During this process, the relative humidity is maintained at approximately.  70% and the temperature is 55°C.

Post conditions: EtO gas is removed by repeatedly vacuuming and then introducing air into the sterilization chamber until EtO gas is removed (8-12 hours).

Optional:

1. Automatic weighing and dosing
2. Air circulation system in the cabinet
3. Nitrogen displacement function in the sterilization / resolution
4. All-round stainless steel sterilization cabinet
5. Automatic feeding and outlet system
6. Force resolution function
7. Ethylene oxide concentration monitoring and alarm system in the workshop
8. Wireless Verification Sensor
9. Feed-out safe exhaust system
ModelOuter Size(L×W×H)
Volume of inner container:1,3, 6, 10, 15, 20.....100m3
Chamber materialInner chamber and outchamber,and all pipes directly connect with EO gas and steam are stainless steel
Sterilizing temperature20-100ºC
Sterilizing pressure-90~+80Kpa
EO concentration250~200mg/L
Pre-Vacuum-90Kpa(vacuum can be done sectionalized)
Sterilizing time3~24 hours choosable
Heating Maximum Power54KVA
Power source3-phase,5-wire 380V 50Hz


Company Information:

Product Tag:
Related categories:
Scroll to Top