Hot 10A/20A Charging Current Modified Sine Wave 500va 1000va 2000va Homage UPS

Min.Order: 1
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ 45 ~ 70.8

Description
Hot 10A/20A Charging Current modified sine wave 500va 1000va 2000va homage ups
Main for home and office Appliance such as TV,refrigerator,fan,lights,computer etc.
  • User selectable for accepting wider input voltage.
  • Rack Tower design., high Frequency, off mode charging.
  • Compact size for convenient use and storage.
  • Built-in from 8Amp super charger up to 100Ah battery.
  • Small scale and cost effective inverter for home appliances and office equipments
  • Three - steps intelligent charging control to recharging time. 

PG Series Power Inverter 500va /1000va /2000VA  LCD Display
Rated Capacity 500VA/300W 1000VA/600W 2000VA/1200W 
Input
Models 120V Models230V Models 
Nominal Voltage 110V/115V/120V Selectable 220V/230V/240V Selectable  
Input Frequency47Hz ~ 65Hz,  50/60Hz Auto-Sensing 
Efficiency95%(Normal Mode) 
Noise Filtering Full Time EMI/RFI Filtering 
Over Current Protection By Re-Settable Over Current Protector 
Voltage Range 90 - 145VAC Or 170-280VAC ( Narrow Range )
50-145VAC / 90-280VAC (Wide Range) 
Surge Protection 324 Joules 
Output 
Rated Power500va/300w 1000VA/600W 2000VA/12000W 
Output Voltage100V/110V/115V/120V Selectable 220V/230V/240v selectable 
Voltage WaveformModified Sine Wave
Crest Factor 3:01
Output Frequency (Synchronized-Mains) Auto Select For 50/60Hz 47Hz ~ 55Hz For 50Hz Nominal; 56Hz ~ 65Hz For 60Hz Nominal 
Regulation(Battery Mode) 10% -18% 
Transfer Time 15ms Typical 50ms Max 
Protection Over Load, Discharge, Overcharged 
Battery Type Lead-Acid 12V 25Ah  ~ 250Ah 
Voltage 500VA/1000VA :DC12V ; 2000VA :DC24V 
Backup Time Depend On Battery 
Charging Method 3 Steps Super Charge Mode 
Charging Current 10A-20A Adjustable Charge Current
Protection Over Current Protection Over Charging Voltage Protection  (No More Than 15V) Deep Discharge,  Overload Protection 
Communications & Management 
Control Panel(LCD Indicator) Input & Output Voltage, Battery Capacity,
Load Capacity,  Frequency, Line Mode, Battery Mode 
Audible Alarm Low Battery Sounding Every 2 Seconds 
Overload Sounding Every 0.5 Second 
Fault Continuously Sounding 
Environment And Safety 
Operating Environment 0~40 Degrees Centigrade, 0 - 90% Non Condensing 
Transit/Storage
Temperature 
-15ºC To 55ºC (5ºF To 131ºF) D39
Operating Altitude 0 ~ 3000 Meters
Audible Noise <=50dba 
Safety Markings CE.FCC
Quality Control System ISO 9001 
Physical 
Dimensions (H×D×W) 355*130*230mm 
N.W/G.W(Kg) 1.6/2 (Kg)2/2.3 (Kg) 2.2/2.6 (Kg) 
Packing 6pcs/Carton 
 
Product Tag:
Related categories:
Scroll to Top