Micro Water Turbine / Pelton Turbine / Micro Pelton Turbine

Min.Order: 1
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ -1

Description
Micro water turbine / pelton turbine / micro pelton turbine

Quick Detail:
water head: 60 to 2,000m
Rated power: 100KW~50MW
Frequency: 50HZ or 60HZ


Description:
      The impulse type turbines are the best election for high head and small discharge hydraulic power resources. They have compact structure, small size, high efficiency and need fewer investments.They have been divided into Turgo and Pelton.
    Pelton turbine also called a free-jet turbine or Pelton wheel.It needn't draft tube, spiral case and complex distributor, the construction is simple, maintenance and management is convenient.  It is favorable for power plant with high water head and long diversion steel pipe. Its operation is reliable and no damage to the environment.
    Turgo turbine or called inclined-jet impulse turbine .Its nozzle make the angle of 22.5°with the rotating plane of the runner.
    Turgo turbine has higher specific speed,wide range of application as well as easy match directive driving generator,except simple of construction, reliable operation,convenience in operation and maintenance etc.
    The impulse type turbines made by Fuchun are ranging from 60 to 2,000m in water head,100kW to 20MW in capacity and 0.55 to 3 in runner diameter. Theirs shaft arrangements are either vertical or horizontal and they may have single nozzle, twin or multi-nozzles.





Company Information

   Our company is an experienced manufacture and engineering Company in small scale hydro power equipment ( 100Kw to 50Mw). We play the role of manufacture and EPC contractor and could supply water to wire equipments and services. As turbine manufacture more than 50 years experience.
   Our factory occupies 560,000 square meters of land, which includes 18 workshops, over 320 sets of heavy and precision producing and testing machinery; scientific research development center in the southern China, and various testing facilities. We have a general technical staff of 380 and 135 senior technical professionals. 




Reference List of Some Export Projects
No. Country and Power Station Exported to Technical Parameters Type Qty Date of contract
1 HPP2
 Guatemala
Rated head:305m
Rated flow:0.385m³/s
Frequency:60Hz
Outgoing line voltage:480V
CJA475-W-80/2×6.5
SFW1000-8/1180
1 2013.06
2  Pakistan  Type:HL855a
Runner diameter:1750mm
27Mw spare runners  1 2013.06
3 UK Rated head:73.8m
Rated flow:0.1325m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-55/1×7 1 2013.03
4 turkey Rated head:203m
Rated flow:0.312m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-80/1×8.5
SFW500-8/990
1 2013.05
5 Sri Lanka Rated head:88m
Rated flow:1.41m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLA550-WJ-62
SFW1000-6/1180
1 2013.05
6 Congo Rated head:210m
Rated flow:0.423m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-80/1×9.5
SFW700-8/1180
1 2013.05
7  
Ecuador
Rated head:925m
Rated flow:0.26m³/s
Frequency:60Hz
Outgoing line voltage:4.16KV
CJC601-W-100/1×5
SFW1980-6/1430
2 2012.12
8
Philippines 
Rated head:4m
Rated flow:10m³/s
Frequency:60Hz
Outgoing line voltage:440V
ZD-LH-160
SF320-36/2150
1 2012.12
9
 Guatemala
Rated head:128m
Rated flow:0.6+0.3m³/s
Frequency:60Hz
Outgoing line voltage:440V
CJA475-W-80/2×9
SFW614-12/1180
CJA475-W-80/2×6.5
SFW302-12/990
2 2012.11
10 UK Rated head:48.51m
Rated flow:0.351m³/s
Frequency:50Hz
Outgoing line voltage:400V
XJA-W-55B/1x8.5 1 2012.11
11  UK Rated head:47.48m
Rated flow:0.38m³/s
Frequency:50Hz
Outgoing line voltage:400V
HL110-WJ-42 1 2012.11
12 UK Rated head:25.44m
Rated flow:0.332m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD54-WJ-50 1 2012.11
13 UK Rated head:35.19m
Rated flow:0.3m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD54-WJ-50 1 2012.11
14 UK Rated head:37.82m
Rated flow:0.291m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD54-WJ-50 1 2012.11
15  HPP1
 Guatemala 
Rated head:60m
Rated flow:1.24m³/s
Frequency:60Hz
Outgoing line voltage:440V
HLA575c-WJ-56
SFW600-8/990
2 2012.8
16 UK Rated head:58.1m
Rated flow:0.169m³/s
Frequency:50Hz
Outgoing line voltage:400V
XJA-W-40/1×9
SFW100-8/590
1 2012.04
17 Ecuador Rated head:38m
Rated flow:1.64m³/s
Frequency:60Hz
Outgoing line voltage:440V
HL220-WJ-50
SFW470-8/990
1 2012.04
18 Italy  Rated head:43m
Rated flow:0.59m³/s
Frequency:50Hz
Outgoing line voltage:400V
HL110-WJ-42
HLD54-WJ-40
2 2012.03
19  Pakistan  Type:HL855a
Runner diameter:1750mm
27Mw spare runners  3 2011.11
20 ITALY Rated head:134m
Rated flow:0.25m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA475-W-80/2×6.5
SFW250-10/850
2 2011.06
21 Italy Rated head:228m
Rated flow:0.4m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA475-W-85/1×9.5
SFW715-8/1180
3 2011.05
22  UK Rated head:61.8m
Rated flow:0.221m³/s
Frequency:50Hz
Outgoing line voltage:400V
XJA-W-42/1×10
SFW100-8/590
1 2011.03
23 HPP1
Albania
Rated head:379.7m
Rated flow:0.685m³/s
Frequency:50Hz
Outgoing line voltage:10.5KV
CJA475-W-105/2×7.5
SFW2150-8/1730
1 2010.12
24  HPP2
Albania
Rated head:461.6m
Rated flow:0.786m³/s
Frequency:50Hz
Outgoing line voltage:10.5KV
CJA475-W-115/2×8
SFW3000-8/1730
1 2010.12
25  Italy  Rated head:29m
Rated flow:3.2m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD41-WJ-42
HLD74-WJ-60
2 2010.12
26
Afghanistan 
Rated head:36m
Rated flow:1.67m³/s
Frequency:50Hz
Outgoing line voltage:400V
HL295-LJZ-50
SF500--6/850
5 2010.12
27  
Pakistan
Rated head:206m
Rated flow:0.89m³/s
Frequency:50Hz
Outgoing line voltage:6.6kV
CJA475-W-100/2×10
SFW1500-10/1430
2 2010.08
28  HPP1
Vietnam
Rated head:385m
Rated flow:11.24m³/s
Frequency:50Hz
Outgoing line voltage:13.8kV
HL69-LJ-205
SF37500-10/3600
2 2010.02
29  
Mozambique
Rated head:206.8m
Rated flow:0.358m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-80/1×9
SFW570-8/990
1 2010.04
30
Pakistan 
Rated head:47.5m
Rated flow:2.62m³/s
Frequency:50Hz
Outgoing line voltage:6.6kV
HLA696-WJ-68
SFW1000-8/1180
3 2010.03
31  Italy  Rated head:35m
Rated flow:4.25m³/s
Frequency:50Hz
HLA696-WJ-82
SFW800-12/1430
HLJF2504-WJ-56
SFW400-8/990
3 2010.01
32 Italy  Rated head:265m
Rated flow:0.734m³/s
Frequency:50Hz
Outgoing line voltage:6.3kV
CJA475-W-110/2×8.5
SFW1600-10/1730
2 2009.07
33 Georgia Rated head:289m
Rated flow:1.775m³/s
Nozzle No.:2
Bucket No.: 20
Runner Outer Diameter: 1600mm
RUNNER DIAMETER: 1300mm
4000KW Pelton runner change  3 2009.06
34
Vietnam
Rated head:86.2m
Rated flow:22.5m³/s
Frequency:50Hz
Outgoing line voltage:10.5kV
HLA883-LJ-155
SF17000-12/3250
2 2009.01
Scroll to Top