Secondary Injection Protection Relay Test Set

Min.Order: 1
Product origin: Chongqing, China
Infringement complaint: complaintComplaint
US$ 3000 ~ 3500

Description
GDJB-PC Secondary Injection Protection Relay Test Set 



Introduction:
GDJB-PC Secondary Injection Protection Relay Test Set is applied to test the relay unit in relay protection system. 

At the same time GDJB-PC Secondary Injection Protection Relay Test Set could be considered as a universal  three phase AC/DC voltage source or current source.


Features:
-Intelligent mainframe that is used high speed DSP.
-Separately running
-Run with connecting to computer
-16 bit DAC chip
-Big screen LED
-"Idiot" operation
-New type power amplifier
-Current, voltage output directly
-Self-protection
-Abundant contact
-Compounded structure
-Abundant capabilities against low price;


3. Functions
-AC current and voltage based protection relay unit test
-DC current and voltage based protection relay unit test
-Frequency protection relay unit test
-Harmonic protection relay unit test
-Differential protection relay unit test
-Zero-sequence protection relay unit test
-Distance protection relay unit test
-Power system network fault simulation.
 
4. Technique Index
No.ItemsSpecifications
Alternating Current(AC) output
1Output accuracy0.5magnitude
2Phase current output (effective value)0~30A
3Three parallel phase current output (effective value)0~90A
4Phase current value with long time under permission (effective value)10A
5Phase current maximum power output420VA
6Three parallel phase current maximum power output900VA
7Three parallel phase current maximum work time10s
8Frequency range (base wave)20~1000Hz
9Harmonic frequency number1~20 time
Direct Current(DC) output
1Output accuracy0.5magnitude
2Current output0 ~ ± 10 A/each phase
0 ~ ± 30 A/every three parallel
3Maximum output of load voltage20v
Alternating Voltage output
1Output accuracy0.5magnitude
2Phase voltage output (RMS)0 ~ 120v
3Line voltage output (RMS)0 ~ 240v
4Phase voltage/line voltage power output80VA/100VA
5Frequency range (base wave)20 ~ 1000Hz
6Harmonic frequency number1 ~ 20 times
Direct voltage output
1Output accuracy0.5magnitude
2Phase voltage output amplitude0 ~ +160v
3Line voltage output amplitude0 ~ + 320v
4Phase voltage/line voltage power output70VA/140VA
 
1AC current and voltage error<0.5%RDG+0.05%FS
2DC current error<0.5%RDG+0.05%FS
3DC voltage error1%RDG+0.1%FS
4Binary inputActive node 0~250V, 0~6V for "0", 6~250V for "1", passive node: 20mA max
5Binary outputDC 220V/0.2A, AC 220V/0.5A
The switch quantity and time measurement
1Switch parameters input7 ways; Empty contact: 1~20mA, 24v;
Power contact access: "0":0~+6V;  
"1":+11 V~+250V;
2Switch parameters output2 couples     DC: 220V/0.2A;   AC: 220V/0.5A
3Time measurementMeasuring range: 0.1ms ~ 9999s / 0.1ms
 
1Power supplyAC220V ± 10%, 50Hz/60Hz
2Environment temperature0~50°C
3Humidity≤85%RH
4Weight<18KG

Product Tag: