Digital Analog Signal Level Meter

Min.Order: 1
Product origin: Hangzhou, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 260 ~ 265

Description
HT8553 Signal Analyzer is specially designed and manufactured for CATV system installation and testing. It's a portable instrument, easy to carry with many functions .This instrument can test CATV signal level both at channel and frequency mode. At SCAN mode, it can scan all channels and store signal level. At spectrum mode, it can carry out spectrum display and test for a certain frequency range. Also it can measure CATV TILT,C/N, trunk cable Vo1tage, etc. The big LCD clear1y displays all testing results. It especially fit for CATV station as a professional measurement instrument.
 

Features

1. Specifications (Digital & Analogue Signal)

1.1 LEVEL

 

Frequency Range:

5/46-870MHz

Resolution Bandwidth:

280KHz ± 50KHz

Channels:

All Channels

Level Range:

35dBμV - 115dBμV

 

Accuracy:

±1.5dBuV(under room temperature)

±2.5dBuV(- 10 - +40ºC)

Input Impedance

75Ω(BNC or F connector)

Wave detection

Peak value

 

 

1.2 AUTO SCAN TESTING

Max Channel Scan:

100 Channels

Scan Range:

All Channels within 46--870MHz

Scan Speed:

30 Channels/Min

Memory Groups:

23 Groups (00--22) Each group store Max 100 Channels.

 

2. Voltage

 

Voltage Range:

0 -- 100VAC

Accuracy

±1.5V

Resolution

0.1V

C/N (The measure result is only for reference, not accuracy result)

Level Range:

80dBuV - 105dBuV

 

 

3. Power Supply

 

DC Supply:

DC 7.2V/1.6Ah rechargeable battery

AC Supply:

AC 220V/50Hz±10%

Battery Working Hours:

Longer than 4.5 hours at continuous working mode

Recharging Time:

12 -- 14 hours

Others

Dimension:

215mm x 95mm x 47mm

Weight:

610g(Without charger)

Working Temperature:

-10ºC -- + 40ºC

Display LCD

128X64 Matrix Super Big LCD with back light

 

 

4. Accessories

 

Battery Charger

1PCS

RF Input Port:

F Type: 2PCS

User Manual

1 Copy Document

 

5. DVB Sepcifications

Specifications 

Frequency Range

5/46MHz~870MHz

Frequency Resolution

10KHz

Frequency Accuracy

±10x10-6

Average Power

35dBμV~115dBμV

Power Resolution

0.1dB

Power Accuracy

±2.0dB(under room temperature)

Input impedance

75Ω

MER

22~39dB

MER Accuracy

±2dB

EVM

BER

1E-4~1E-8(after RS)

Modulation

16/32/64/128/256QAM

Constellation Diagram









 
Scroll to Top