3/3 Phase 0.9PF Low Frequency Online UPS Power 10kVA - 400kVA for Industry, Telecom, Communication, Hospital Equipents Use.

Min.Order: 1
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ 20000

Description
Big UPS Industry UPS Telecom UPS Low Frequency 3 Phase UPS System 200K-600Kva
1: Big UPS with Three Phase 380/400/415Vac or 190/208/220Vac Input/Output
2: Low Frequency UPS can be used for data center, industrial process,ATM,Bank,Hospital Equipments and other mission-critical equipments
2: Digital LCD Touch Screen for UPS Operation
3: EPO function for UPS
 

Low Frequency Online UPS Low Frequency Strar Series LF33 10K-400K(3Ph in/3Ph out)

Key Features

1: Use advanced 6th generation DSP and full digital control technologies to realize higher system stability.
2: Output power factor is 0.9, carrying capacity than conventional UPS with 10% above, as users reduce investment cost.
3: Advanced distributed active parallel technology can realize parallel operation of 6PCS UPS units without the need of centralized bypass cabinet.
4: 6-inch extra large LCD that can display 12 language (Chines,English,Russian,Spanish,French and so on).
5: Extra wide input voltage and frequency range make it adapt to severe power grid environment.
6: Intelligent battery management maintains battery automatically to prolong the battery life.
7: Standard input/output filter improves the system EMC performance.
8: Extra strong capability to withstand output overload and short circuit, ensuring the system stability and system safety under extreme conditions.
9: 
Layered independently-sealed ventilation channel and re-dundant fan, circuit boards with protective paints and a dust filter embedded make it highly efficient to dissipate heat and protect the product effectively under severe environment.

Application
Mainly used in large IDC rooms, bank/securities settlement center, communication network management center, semiconductor product lines and large automation production and its control system. According to the special needs of users was improved, and used in large sports venues, conference room, theater and highway and railway tunnels metal halide lamp lighting system.

 

ModelLF33 Series
Rectifier Type6p12p6p12p6p12p6p12p6p12p12P12P12P
Rated Nominal10KVA/9KW20KVA/18KVA30KVA/27KW40KVA/36KW60KVA/54KW80KVA/72KW100KVA/90KW120KVA/108KW
Rated input voltage380/400/415VAC   3-phase 4-wire
Rated frequency50/60HZ
Input  parameters
Input voltage range±25%
Input frequency range45Hz~65Hz
Input soft start function0-100%   5-300settable
Input power factor>0.8
Input harmonic current<20%
Bypass
Bypass voltage range-20%~+15%
Bypass frequency range50/60HZ±10%
Output parameters
Inverter output voltage380/400/415VAC  3-phase 4-wire
Voltage stability±1%(Steady  status),±3%(Transient  status)
Frequency50/60Hz
Mains power synchronization window±5%
Actually measured frequency accuracy (internal clock)50/60Hz±0.05Hz
Output power factor0.9(Output 90kW per 100kVA)
Transient response time<5ms
Inverter overload capabilityAt 0.9 power factor, 110% for 1 hour, 125% for 10 minutes  and 150% for   60s
Short circuit current from inverter3ph 1.5ln for 5seconds,1ph 2.9ln for   5seconds
DC Voltage360/384/432/480VDC
Maximum Bypasscapability1000% for 100ms
Phase shift CharacteristicWith 100% balanced load<1°
With 100% imbalance load<1°
Total harmonic Distortion (THDv)100% linear load<1%
100% non- linear load<3%
System  efficiency (fullUp to 94% (inverter efficiency is up to  98%)
Rectifier output parameters
Charger output voltage stability1%
DC ripple voltage≤1%
Operating environment
Operating temperature range0~40°C
Storage  temperature-25~70°C(Without battery)
Relative humidity0~95%  No condensation
Maximum operating height≤Elevation 1000m, for elevation above 1000m, derate by 1% for every increase of  100m
Noise (1m)58-68dB
Protection levelIP20
StandardSafety: IEC60950-1 IEC62040-1-1 UL1778 EMC IEC62040-2 CLASS C2 EN50091-2 CLASS A Design and Test IEC62040-3
Physical parameters
Weight (kg)980142012001750135020001600220021002750369063907390
Width(mm)900125012501640125016401640228022802280283539553955
Depth (mm)855855855855855855855855855855100010901090
Height (mm)1900190019001900190019001900190019001900195019501950
* Product specifications are subject to change without further notice
ModelHE33 200-400K
Rectifier Type6p12p6p12p6p12p6p12p6p12p
Rated Nominal120KVA/108KW160KVA/144KVA200KVA/180KW300KVA/270KW400KVA/360KW
Rated input voltage380/400/415VAC 3-phase 4-wire
Rated frequency50/60HZ
Input parameters 
Input voltage range±25%
Input frequency range45Hz~65Hz
Input soft start function0-100%  5-300settable
Input power factor>0.98(If harmonic filter is added)
Input harmonic current (THDi)4.5%(If harmonic filter is added) 
Bypass 
Bypass voltage range-20%~+15%
Bypass frequency range50/60HZ±10%
Output parameters 
Inverter output voltage380/400/415VAC 3-phase 4-wire
Voltage stability±1%(Steady status),±3%(Transient status)
Frequency50/60Hz
Mains power synchronization window±5%
Actually measured frequency accuracy (internal clock)50/60Hz±0.01Hz
Output power factor0.9(Output 90kW per 100kVA)
Transient response time<5ms
Inverter overload capabilityAt 0.9 power factor, 110% for 1 hour, 125% for 10 minutes and 150% for 60s
Short circuit current from inverter3ph 1.5ln for 5seconds,1ph 2.9ln for 5seconds
Maximum Bypass capability1000% for 100ms
Phase shift characteristicWith 100% balanced load<1°
With 100% imbalance load<1°
Total harmonic
Distortion(THDv)
100% linear load<1%
100% non-linear load<3%
System efficiency (full load)Up to 94% (inverter efficiency is up to 98%)
Rectifier output parameters
Charger output voltage stability1%
DC ripple voltage≤1%
Operating environment 
Operating temperature range0~40°C
Storage temperature-25~70°C(Without battery)
Relative humidity0~95% No condensation
Noise (1m)58-68dB
Protection levelIP20
StandardSafety: IEC60950-1 IEC62040-1-1 UL1778 EMC IEC62040-2 CLASS C2 EN50091-2 CLASS A Design and Test IEC62040-3