Power Cable Compound Bushing Outdoor Terminal 110kv

Min.Order: 1
Product origin: Ningbo, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 3500

Description
Introduction:
Compound Bushing Outdoor cable terminal is consist of a epoxy fiberglass tube and outside covered insulative
silicon rubber compound bushing, which is of weather fastness. Both ends are sealed by aluminum alloy flange,
possessing good corrosion resistance. And terminal bushing interior is filling with insulating silicone oil.

Application:
- Indoor & Outdoor
- Pollution class: Apply to 1V pollution area
- Applied cross-section of cable standard: 240-1600mm2
- Terminal insulating level, Recommended Operating Temperature and short circuit temperature should be in
accordance with the technical requirements of its matching cable.

Product Features:
- Possessing all advantage of Porcelain Type Terminal
- Excellent Mechanical Properties
- Weather Resistance
- Excellent Explosion-proof Performance
- Light weight, easy to installation and easy to transportation

Technical parameters:
NO.ItemUnitStandard Data
1Approvals IEC60840, GB/T11017
2Basic Structure  Compound Bushing
3Conductor PoleMaterial T2
Specificationmm2240~400500~8001000~1600
Terminal Outer DiametermmΦ28Φ45Φ50
Connection with Cable Conductor Pressure welding
4Corona-proof Cover  Equipped
5Sealing between upper-lower flange and pole/ Sealing between upper-lower
 flange and bushing
 No Sealing within 1 hour(Air pressure is 0.2M Pa)
6BushingTechnical Specification Ref. GB 772
7Stress Corn Material  Imported Ethylene Propylene Rubber
Structure Prefabricated Type
8Epoxide InsulationMaterial Ethoxyline resin
Structure Prefabricated Type
9Stress Corn Hold-down GearMaterial Albronze
Structure Spring Compression Components
10Terminal Filling Liquid ( Material ) Silicone Oil
11Supporting Insulator Ref. GB/T 775
12Terminal Specificationmm2
 
240~1600
13Height ( From top of the support to peak of the pole)mm1769
14QualityKg2120
15Rated Voltage, Uo/U kV64/110
16Max. Running Voltage, UmkV126
17Lightning Stroke Withstand Voltage Peak(±/10 times)kV550
18Conductor Rated TemperatureNormal Condition°C90
  Transition Condition(Circuit current 
maintain time is less than 5 seconds.)
°C250
19Rated CurrentANot less than connective cable
20Circuit CurrentkA/s
 
Not less than connective cable
21Range of applicable environmental temperature°C-40~ +60
22Terminal insulation Creepage distancesmm4032
23Terminal Allowable Horizontal Pull of Connective WirekN≥2
24Service life of Terminal design year30
25Sealing type of its tail Water proof ribbon, Cold sealing belt, seal pipe, 
heat-shrink tube
Metal shielding layer grounding Material Tinned Copper Braided Wire
Electrical Connection Welded in tin solder or Lead sealing
Equivalent cross-sectionmm2240


Our advantages:
Quality Assurance
--From the very beginning, VILLE ensures quality in every step to achieve the best quality.
 Experience Sharing
--With more than 30 years' experience in power industry, VILLE brings you an optimized solution.
 Global Service
--Wherever you are, VILLE global network will support and provide you with value.
 Quick Response
--In response to your needs without delay, VILLE  knows the value of your time.

Thanks for choosing VILLE as your reliable partner and
please trust both of us will create a brilliant future!
Product Tag:
Related categories:
Scroll to Top