Features                          
Various functions with Compact and light design
Monopolar cut ( Pure cut , Blend 1 ,Blend 2 ,Blend 3 )
Monopolar Coag ( Fulguate Coag, Contact Coag, Spray Coag)
Bipolar Coag, fully meet different surgery need.
                                                         
Tissue Monitoring Technology  
This technology monitors the tissue density, especially for polypectomy & papillotomy, cutting is smartly divided in
cut & pause, so that coagulation occurs in each pause. The system is intelligent to change the pause interval as
tissue density changes, hence produces fine cutting with coagulation effect.

Patient Return Electrode Monitoring (PREM)
REM (Return Electrode Monitoring) function monitors the range of contact area between a patient and the neutral plate.
If the size is inappropriate, it automatically stop the high-frequency current with audible alarm to minimize the danger
of burning incidents.

Compatible with other surgical equipment
Endoscopy, HV Argon Plasma Coagulator, Optimum Smoke Evacuation System.

Waterproof Panel Operation  
Microcomputer Auto Control; Three-zone (LED ) digital display.

Application
General Surgery, Gastroenterology , Dermatology,Vascular Surgery, Obstetrics and Gynecology, Liver surgery,
Heart/Thoracic Surgery; ORL/ ENT surgery,  Minimally Invasive Surgery (MSI) Cerebral surgery, Neurosurgery,
Orthopedics & Plastic Surgery, Trans Urethral Resection (TUR) and other open surgery.


Technical Specification
Working  ModeMax PowerPeak  Voltage

Monopolar Cut
Pure cut 300W1500V
Blend 1 250W2000V
Blend 2 200W2500V
Blend 3150W3000V
Monopolar CoagFulgurate Coag 120W4000V
Spray Coag100W4020V
Contact Coag 80W4700V
Bipolar Coag Bipolar Coag70W620V
Electrical requirement
Operating Voltage220V±22VMeasuring Frequency530KHz±2
Monopolar Rate Load  500ΩBipolar Rate Load        100Ω
Max Input Currency1400VA
 Environmental Conditions for Use
ConditionRange
Temperature 50°C to 40°C
Relative humidity≤ 95% non-condensing
Pressure 700 hPa to 1060 hPa
Environmental Conditions for Transport and Storage
ConditionRange
Temperature -40°C to 55°C
Relative  humidity≤ 93% non-condensing
Pressure 500 hPa to 1060 hPa
Dimension (L×W×H)350mm×320 mm×100mm
Weight 15kg

Standard Accessories
Code Accessories Name   Quantity
1Electrosurgical Unit         1
2Reusable ESU Pencil           2
3Disposable patient plate         5
4Reusable patient plate cable         1
5Resuable Bipolar forceps         1
6Reusable Bipolar cable         1
7Double  Footswitch            1
8Power cable                1
9Service Manual         1


Product Tag:
Related categories:
Scroll to Top