Circuit Breaker Time Trip Velocity Analyzer

Min.Order: 1
Product origin: Wuhan, Hubei, China
Infringement complaint: complaintComplaint
US$ -1

Description
Introduction
The High-Voltage Circuit Breakers Analyzer is designed to meet the need of testing High-Voltage Circuit Breakers . It takes the ARM7 unit for core to sample, process and then output; the main characteristic is that it's operated in alt. It has many advantages such as intelligence, multi-function, accurate data, strong anti-jamming, easy operation, small size, beautiful appearance, etc; It can test the Circuit Breakers as follows: indoors or outdoors Circuit Breakers with less oil or more oil, vacuum Circuit Breakers, SF6 Circuit Breakers and so on. 

Features
1, Test standard: IEC62271 
2, Closing and opening time measurement of 12 channels
3, Max difference of closing or opening time measurement of three phases
4, C-O and O-C time measurement
5, Rated operation sequence test
6, Bounce time and frequency measurement of breaker closing
7, Circuit breaker closing and opening speed measurement
8, Travel-time, Coil current-time curve of circuit breaker operation measurement
9, Travel and clearance of circuit breaker measurement 
10, Variable DC circuit breaker operation power supply
11, Closing arc resistance value and connected time measurement                                        
12, Closing time and opening time of graphite circuit breaker measurement
13, Print test results by internal micro printers



Main Technical parameters
Sr noCHANNELSCONFIGURATIONRANGERESOLUTIONACCURACY
  1Contact Status12 channels for Switch off time and switch on time, in-phase synchronization and phase to phase synchronization0.01~25000mSMinimum 0.01mS250mS: 0.01ms±2 digit
2500mS: 0.1ms±2 digit
25000mS: 1ms±2 digit
  2Auxiliary ContactsDry/Wet selectableDC 0~300VMinimum 0.01mS250mS: 0.01ms±2 digit
2500mS: 0.1ms±2 digit
25000mS: 1ms±2 digit
  3Coil Current 20A0.01A 
  4Closing Resistance*6 channels50~10000 ohm0.1 ohm1%
  5Breaker ControlIndustrial personal Computer control
  6Trigger OptionsOpen, Close, C-O, O-C, O-C-O
  7Sampling Speed 20mS0.01mS0~2mS: ±0.1ms±1 digit
>2mS: ±0.2ms±1 digit
  8TripVacuum circuit breaker 50mm0.1mm±0.1ms±1 digit
SF6 circuit breaker  (for option)300mm1mm
Less-oil circuit breaker (for option)600mm
  9Test ResultsClear graphical result with test header and computation footer
 10Display320 x 240 LCD
 11CommunicationUSB port, for data download
 12Printer56 mm paper width, thermal printer
 13EnvironmentTemperature: operation: -10° C to 50°C; Storage: -30°C to 70°C 
 14Power220V±10% 50Hz±10%
 15Demension360mm(L)×280mm(W)×300mm(H)
 16Weight10kg
 17* Model no.DL-209 is without the function of closing resistance.


Panel

Sr no.MarkDescription
  1A1 B1 C1/A2 B2 C2
A3 B3 C3↓/A4 B4 C4
12 channels measuring time
   2Internal TriggerSwitch off (on) control DC source is provided
  3External triggerDirectly join up in parallel at two ends of switch on and switch off coils when the mode of external trigger is applied, and take the electric signal on the coil as the synchronizing signal.
  4Energe storageSupply DC storage power
  5SensorInput of trip and speed
  6EarthProtection ground
  7USBPC communication
  8Switch on/off220V±10% 50Hz±10% 10A
  9


Function key press  
Increase, decrease of liquid crystal contrast
"Up, down" Move the cursor up and down or increase, decrease the numerical value where the cursor points. 
"Left, right" Move the cursor leftward and rightward.
OK [OK] means selecting current menu or confirming the operation
Return [Return] means returning to the upper menu or cancelling the operation
Reset [Reset] means resetting of the instrument
 10Output indicator 
 11Panel printerPrint out test reports and illustrations
 12Display320 x 240 LCD



Accessoreis
DescriptionSpecQtyRemarks
Host 1 unit 
Accessaries case 1 unit 
Control cables6 m1 sets 
Synchronous cables6 m1 sets 
Sensor cable6 m1 unitMulti core shielding wire
Fracture signal wires4 m 6 unitsRed 2pcs,green 2pcs and yellow 2pcs
Fracture signal ground wires4 m1 unitBlack
Fracture signal wires8 m 6 unitsRed 2pcs,green 2pcs and yellow 2pcs
Fracture signal ground wires8 m1 unitBlack
Short connection wire2 m 2 unitsBlack
Grounding wire2 m1 unitClear
Power supply cable1.5 m1 unit 
Linear Sensor50 mm1 setVacuum circuit breaker testing
Rotary Sensor 1 set 
Magnetic base  1 unit 
Fuse20A2 pcs 
Print Paper57.5mm  2 units 
Operating manual  1 unit 
Calibration  1 unit 
SF6 circuit breaker300mm1For buyer's option
Less-oil circuit breaker 600mm1For buyer's option