Distribution Box, Junction Box, Cable Box, Consumer Unit, Distribution Power Box

Min.Order: 1
Product origin: Shanghai, China
Infringement complaint: complaintComplaint
US$ -1

Description
We procue distribution box, consumer units, miniature circuit breaker (MCB), leakage circuit breaker, residual current circuit breaker (RCCB), residual current circuit breaker with overcurrent protection (RCBO), circuit breaker busbar, molded case circuit breaker (MCCB), thermal overload relay, thermal relay, contactor, motor starters, motor protection circuit breaker, current transformer, isolator, disconnect switch, electric bell, bell transformer, surge protector, surge protective device, modular signal lamp, weatherproof isolating switch. Weather Protected Isolating Switch



Distribution  Box W Series

PicturesModelDimensionDescription

ASTTW001 Power box---
2X32A IP66 Socket and MCB (RCBO)
2X20A IP66 Socket and MCB (RCBO)

ASTTW002 Power box---
2X32A IP66 Socket and MCB (RCBO)
2X32A IP66 Socket and MCB (RCBO)

ASTTW003 Power box---
2X15A IP66 Socket and MCB (RCBO)

ASTTW004 Power box---
2X32A IP67 IEC Socket and MCB (RCBO)
2X16A IP67 IEC Socket and MCB (RCBO)

ASTTW005 Power box---
2X32A IP44 IEC Socket and MCB (RCBO)
3X16A IP44 IEC Socket and MCB (RCBO)

ASTTW006 Power box---
1X16A IP44 IEC Socket and MCB (RCBO)
1X32A IP44 IEC Socket and MCB (RCBO)

ASTTW008 Power box---
2X16A IP67 IEC Socket and MCB (RCBO)

ASTTW009 Power box---
2X16A IP67 IEC Socket and MCB (RCBO)
2X32A IP67 IEC Socket and MCB (RCBO)

ASTTW010 Power box---
3X10A Wall switch and MCB(RCBO)
1X1.8M leads    1X10A IP66 plug

ASTTW011 Power box290X160X530mm
2X32A IP44 IEC Socket and MCB (RCBO)
5X16A IP44 IEC Socket and MCB (RCBO)

ASTTW012 Power box290X150X400mm
2X32A Ip67 IEC Socket and MCB (RCBO)
3X16A IP67 IEC Socket

ASTTW013 Power box290X150X400mm
6X16A IP44 IEC Socket and MCB (RCBO)

Distribution  Box G Series

PicturesModelDimensionDescription

ASTTG001
Power box
290X160X530mm(H,W,D)
6X3P 15A waterproof socket
     2X3P 16A CEE waterproof socket

ASTTG002
Power box
290X150X400mm
2X3P 15A waterproof socket
            1X5P 32A waterproof socket and switch
1X1.8M lead and 5P 32A waterproof plug

ASTTG003
Power box
350X170X530mm
2X5P 32A waterproof socket and switch
1X5P 20A waterproof socket and switch
2X3P 15A waterproof socket

ASTTG004
Power box
---
3X56SW
3XUKBI/32
3XCEE 5 Pins 32A
3X CEE 4 Pins 32A
Frenquncy:50Hz/60Hz
Volts:220-380V/240-415V

ASTTG005
Power box
---
3X56CB1-4N
3XUKBI/32
3XCEE 5 Pins 32A
Frenquncy:50Hz/60Hz
Volts:220-380V/240-415V

ASTTG006
Power box
---
3X56SW
6X56SO315

ASTTG007
Power box
---3X56SW
6X56SO532

Distribution  Box  L Series

 

 

Model:

ASTTL001 Power box

Dimension:
400x400x570mm(H,W,D)

Side A
1xIEC 5P 63A IP67 plug and MCB(RCBO)
1xIEC 5P 63A IP67 socket and MCB(RCBO)

Side B
4x3P 15A IP66 Socket and RCBO
1x5P 32A IP66 Socket and switch and RCBO

Side C
2X 5P 20A IP66 Socket and waterproof
switch and MCBs(RCBO)
1x5P 32A IP66 Socket and waterproof switch

Side D
6x3P 15A Waterproof Socket and MCBs(RCBO)

 

Model:

ASTTL002 Power box

Dimension:
400X400X570mm(H,W,D)

Side A
1XIEC 5P 63A IP67 plug and MCB(RCBO)
1XIEC 5P 63A IP67 socket abd MCB(RCBO)

Side B
6X3P 16A IP67 IEC Socket and RCBO

Side C
3X 5P 32A IP67 IEC Socket and
waterproof switch and MCBs(RCBO)

Side D
6X3P 16A IP67 IEC Socket and MCBs(RCBO)

 

Distribution  Box M Series

 

 

Model:

ASTTM001 Power box

Dimension:
400X400X460mm(H,W,D)

Side A
1XIEC 5P 32A IP67 plug and MCB(RCBO)
1XIEC 5P 32A IP67 socket abd MCB(RCBO)

Side B
6X3P 16A IP67 IEC Socket and RCBO

Side C
3X 5P 32A IP67 IEC Socket and MCBs(RCBO)

Side D
6X3P 16A IP67 IEC Socket and MCBs(RCBO

 

Model:

ASTTM002 Power box

Dimension:
400X400X460mm(H,W,D)

Side A
1XIEC 5P 32A IP44 plug and MCB(RCBO)
1XIEC 5P 32A IP44socket abd MCB(RCBO)

Side B
6X3P 16A IP44 IEC Socket and RCBO

Side C
3X 5P 32A IP44 IEC Socket and MCBs(RCBO)

Side D
6X3P 16A IP44 IEC Socket and MCBs(RCBO)

 

Model:

ASTTM003 Power box

Dimension:
400X400X460mm(H,W,D)

Side A
1X 5P 32A IP66 Plug and switch MCB(RCBO)

Side B
6X 15A IP66 Socket and MCBs (RCBO)

Side C
1X 5P 32A IP66 Socket and waterproof switch
and MCBs(RCBO)

Side D
2X3P 15A IP66 Socket and RCBO
1X5P 32A IP66 Socket and switch and RCBO
1X5P 20A IP66 Socket and switch and RCBO

 

Distribution  Box S Series

 

 

Model:

ASTTS001 Power box

Dimension:
400X400X460mm(H,W,D)

Side A
Enclosure complete with RCD/MCB 20Amp circuit breaker
1.8M leads
15A plug(IP66 waterproof)

Side B
6X250V 10A/15A outlets

 

Model:

ASTTS002 Power box

Dimension:
380X250X260mm(H,W,D)

Side A
Enclosure complete with RCD/MCB 20Amp circuit breaker
1.8M leads
16A plug(IP67 waterproof)

Side B
6X16A outlets
Side C
1X32A 5P IEC Socket and MCB(RCBO)

 

Model:

ASTTS003 Power box

Dimension:
380X250X260mm(H,W,D)

Side A
2X16A IEC socket and MCB(RCBO)

Side B
4X16A IEC socket

Side C
1X32A IEC socket


PicturesStock No.Spec.    Size(mm)

ASTTMS11half Saddle
 
16,20, 25,
32, 40, 50mm

ASTTMS12
 
Full saddle16,20, 25,
32, 40, 50mm

Australian Electrical Accessories  BH Series



ASTTBH01 Battern holder with plugASTTBH02 Battern holder without plug

Australian Electrical Accessories  JB Series


 


ASTTJB001

Terminal mini junction box with connectors

ASTTJB01

Recess Mounting Block A/B

ASTTJB02

Recess Mounting Block A/B




ASTTJB03

Waterproof mounting modular box

ASTTJB04

Waterproof mounting modular box


 

ASTTWEB

Waterproof/Weatherproof enclosure

Australian Electrical Accessories  PB Series

 

 

ASTTPB01

3 Pin 10A Back Wired Single Socket Outlet

 

ASTTPB02

2 way Plug base


ASTTPB2 10A3 Pin 10A Back Wired Single Socket Outlet
ASTTPB2 15A3 Pin 15A Back Wired Single Socket Outlet
ASTTPB2 20A3 Pin 20A Back Wired Single Socket Outlet

Australian Electrical Accessories  Other Series



ASTTDSE

Electrical accessories

MCB2 terminal 25-20mm Dual screw entry
MCB2 Terminal 25-20mm quadruple srew entry

ASTTMS

35A 1P
80A 1P
80A 3P




NO.1 Roller Clamp No.1
NO.2 Roller Clamp No.2

NO.3 Roller Clamp No.3
NO.4 Roller Clamp No.4

WEATHERPROOF SWITCHES
56SW581-1 (WSC226-1)16A/250V50PCS
49.5×22.5×34.5cm
13.5KGS/11.5KGS
PC meterial IP66
56SW581-2 (WSC226-2)

WEATHERPROOF POWERPOINT SOCKET/OUTLETS
 
TSC-1/WSC227-1 (10A)10A/250V40PCS
43×26.5×37cm                 13.5KGS/12KGS     
PC meterial IP53
TSC-2/WSC227-2 (10A)
 

WEATHERPROOF POWERPOINT SOCKET/OUTLETS (new type)
 
TSC-1/WSC227-1 (15A) new type16A/250V40PCS
43×26.5×37cm                 13.5KGS/12KGS     
PC meterial IP53
TSC-2/WSC227-2 (15A) new type
 

 

56SW series switches are available from 250V 10A TO 500V 63A
They incorparate a positive,rotary action,ON-OFF action and clear marked Impact resistant construction
and material suitable for harsh condition Raised ON-OFF lettering for clear and permanent
marking.

Cat NoRating
(Amps)
Voltage (V)Rated operational current leNo. of Swit
Poles
AC21AAC22AAC23A
56SW110
56SW110/2
10A
10A/2 Way
250
250
10
10
8
8
8
8
1
1
56SW216
56SW220
56SW232
56SW240
56SW250
56SW263
16A
20A
32A
40A
50A
63A
250
250
250
250
250
250
10
20
32
40
50
63
10
20
32
40
50
63
10
20
20
25
25
25
2
2
2
2
2
2
56SW316
56SW320
56SW332
56SW340
56SW350
56SW363
16A
20A
32A
40A
50A
63A
500
500
500
500
500
500
10
20
32
40
50
63
10
20
32
40
50
63
10
20
20
25
25
25
3
3
3
3
3
3


RESIDUAL CURRENT CIRCUIT BREAKER (RCCB)


TypeJVL22-63 I (DZL176-63)
Number of poles2P4P
Rated Current(In)25, 32, 4063A
Rated residual operating current( In)10, 30100300500mA
Rated residual non-operation Current( Ino)0.5In
Rated Voltage(Un)AC 2P: 230/240V 4P: 400/415V
Residual operating current scope0.5In~In
Residual current off-time≤0.3s
TypeAAC
Ultimate short-circuit breaking capacity (Inc)3000A
Endurance≥4000
Terminal protectionIP20


TypeJVL7-125
Number of poles24
Rated Current(In)25324063A
Rated residual operating current(In)1030100300500mA
Rated Voltage(Un)AC 230(240) / 400(415)V
Residual operating current scope0.5In~In
Residual current off-time≤0.3s
TypeAAC
Ultimate short-circuit breaking capacity (Inc)6000A
Endurance4000
Terminal protectionIP20


TypeJVL16-63
Number of poles2P, 4P
Rated Current(In)25, 40, 63A
Rated residual operating current( In)30, 100, 300, 500mA
Rated residual non-operation Current( Ino)0.5In
Rated Voltage(Un)AC 230(240)/400(415)V
Residual operating current scope0.5In~In
Residual current off-time≤0.3s
TypeA, AC
Rated conditional short-circuit current Inc6000A
Endurance≥4000
Terminal protectionIP20


JVL1-63 I model

JVL1-63 II model

JVL1-63 III model

Type        JVL1-63
  Number of poles         2P4P
  Rated Current(In)         25406380100A
  Rated residual operating current( In)         1030100300500mA
  Rated residual non-operation Current( Ino)         0.5In
  Rated Voltage(Un)    AC    2P: 230/240V   4P: 400/415V
  Residual operating current scope         0.5In~In
  Residual current off-time                                       ≤0.3s
   Type         AAC
  Ultimate short-circuit breaking capacity (Inc)          6000A
  Endurance         ≥4000
  Terminal protection         IP20


Type     JVL19-63
  Number of poles     24
  Rated Current(In)     25324063A
  Rated residual operating current(In)     1030100300500mA
  Rated Voltage(Un)     AC  230(240) / 400(415)V
  Residual operating current scope     0.5In~In
  Residual current off-time     ≤0.3s
  Type     AAC
  Ultimate short-circuit breaking capacity (Inc)     6000A
  Endurance     ≥4000
  Terminal protection     IP20


YCM3  MOULDED CASE CIRCUIT BREAKER

 

 

Application:

YCM3 series moulded case circuit breaker is one of the most advanced type breaker in the world, which adopts international advanced design and manufacture technology. They are suitable for short circuit and overload protection in circuit of AC 690V 50/60Hz,rated current from 12.5A to 630A. Its rated insulation voltage is 690V. It can make and break the unfrequently circuit under normal conditions. It takes protecting effect when mouse cage motors unfrequently start, making&breaking and protecting against overload, short circuit and lacking voltage.

1.Tripping Characteristics

Rated Current of release

Themodynamic Release (ambient temp+40°C)

Operational Current of Magnetic Release (A)

1.05In(cold state) operative time(h)

1.30In(heat state) operative time(h)

In≤63

≥1

<1

10In ±20%

63In≤100

≥2

<2

10In±20%

100<In≤630

≥2

<2

5-10In±20%

 

Rate Current of release(A)

Themodynamic Release (ambient temp+40°C)

Operational Current of

Magnetic Release(A)

1.0In(cold state) operative time(h)

1.20In(heat state)

 operative time(h)

1.50In(heat state)

 operative time(h)

1.01In(heat state)

 operative time(h)

12.5≤In≤400

≥2

<2

≤4min

2S<Tp≤10S

12In±20%

2.Main Technical specifications

Type

Rated

Current(A)

Poles

Rated Insulating

Voltage(V)

Rated Operating

Voltage(V)

Arcing Over Distance (mm)

Ultimate Short Circuit Breaking Capacity(KA)

Servies Short Circuit Breaking Capacity(KA)

Operating

performance(times)

ON

OFF

YCM3-100D

12.5,16,

20,25,32,

40,50,63,

80,100

3,4

950

690

0

18

18

1500

8500

YCM3-100N

25

25

YCM3-100H

70

70

YCM3-100L

150

150

YCM3-160D

16,20,25,

32,40,50,

63,80,100,

125,160

25

25

1000

7000

YCM3-160N

36

36

YCM3-160H

70

70

YCM3-160L

150

150

YCM3-250D

160,180,200,

225,250

25

25

1000

7000

YCM3-250N

36

36

YCM3-250H

70

70

YCM3-250L

150

150

YCM3-400D

200,225,250,

300,315,400

35

35

1000

4000

YCM3-400N

45

45

YCM3-400H

70

70

YCM3-400L

150

150

YCM3-630D

315,350,400,

500,600,630

35

35

1000

4000

YCM3-630N

45

45

YCM3-630H

70

70

YCM3-630L

150

150

 

THERMAL RELAY  PAGE1   PAGE2

LR2 THERMAL RELAY

 

LR2-D13

LR2-D23

LR2-D-33 
32-80A

LR2-D-33 
80-93A

  This series of thermal relay can be used in the circuit of 50Hz or 60Hz,rated insulation voltage 660V,rated current 0.1-93A for protecting the phase break when the electric motor is overload. The relay has different mechanism and temperature compensation & can be plugged in LC1-D series AC contactor. At present, it is the most advanced thermal relay in the world.

Specifications
TypeRated working current of thermal relayThermal component
Rated Current (A)Regular or scale of rated current(A)
LR2-D13250.160.10-0.16
0.250.16-0.25
0.400.25-0.40
0.630.40-0.63
1.00.63-1.0
1.61.0-1.6
2.01.25-2.0
2.51.6-2.5
4.02.5-4.0
6.04.0-6.0
8.05.5-8.0
10.07.0-10.0
13.09.0-13.0
18.012.0-18.0
25.017.0-25.0
LR2-D23363223.0-32.0
3628.0-36.0
LR2-D33933223.0-32.0
4030.0-40.0
5037.0-50.0
6548.0-65.0
7055.0-70.0
8063.0-80.0
9380.0-93.0

Characteristic
a. Fundamental parameter of the main circuit
(a). Rated insulation voltage 660V.
(b). Rated working current 25,36,93A separately.
(c). The regulator seal of rated setting current and setting.
(d). Current of the Thermal component (see list 1)
b. Auxiliary Circuit
(a). There are one pair of N/O and N/C contact with electric insulation
(b). Rated insulation Voltage 500V
(c). Rated frequency 50-60Hz
(d). Use group, rated working voltage, appoint thermal current and rated current

Use GroupACLLDCLL
Rated working voltage V220380500220110
Rated working current A4320.10.22
Appointed thermal current A5

Product Tag:
Related categories:
Scroll to Top