1kVA~20kVA Pure Sine Wave UPS High Frequency Online UPS Power

Min.Order: 1
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ 200 ~ 1300

Description
 1KVA~20KVA Pure Sine Wave UPS High Frequency Online UPS Power



APPLICATION:
Servers, Data-Center, Critical network devices, Sensitive Electronic equipment, Telecom.

KEY FEATURES:
High frequency online UPS 6-20KVA with IGBT and short circuit protectioni, larger LCD online UPS, pure sine wave
True online double conversion technology
Wide input voltage range
Zero transfer time
Protection against all types of power problems
No add-on CNTL unit required for parallel connection
Low initial investment and flexible for future expansion
Highest reliability and maximum performance for power
Sharing and redundancy
Equipped with Maintenance Bypass Switch
Smart RS232 and Intelligent slot interface
Sealed lead-acid, maintenance free battery
Specialty of UTseries:
Nominal voltage, nominal frequency and bypass voltage range can de adjusted via LCD panel.

SPECIFICATIONS:
 ModelEX1KEX1KLEX2KEX2KLEX3KEX3KL
CapacityVA/W1000VA/800W1000VA/800W2000VA/1600W2000VA/1600W3000VA/2400W3000VA/2400W
InputNominal Voltage110/115/120VAC or 200/220/230/240VAC110/115/120VAC or 200/220/230/240VAC
Voltage Range60~138VAC or 115~300VAC60~138VAC or 115~300VAC
Frequency Range50Hz :46~54Hz; 60Hz : 56~64Hz50Hz : 46~54Hz : 60Hz; 56~64Hz
PhaseSingle phase with GroundSingle phase with Ground
Power Factor≥0.97≥0.97
OutputVoltage110/115/120 (1±2%) VAC or 208/220/230/240 (1±2%) VAC110/115/120 (1±2%) VAC or 208/220/230/240 (1±2%) VAC
Frequency50/60Hz (Adjustable)                                                                                                                    50Hz AC Mode: Follow AC, Battery Mode: 50Hz  (1±0.2%)                                                                 60Hz AC Mode: Follow AC, Battery Mode: 60Hz (1±0.2%)50/60Hz (Adjustable)
50Hz AC Mode: Follow AC, Battery Mode: 50Hz  (1±0.2%)
60Hz AC Mode: Follow AC, Battery Mode: 60Hz (1±0.2%)
Wave FormPure sine wavePure sine wave
Power Factor0.80.8
Harmonic Distortion≤3% THD (Linear load); ≤7% THD (Non-Linear load)≤3% THD (Linear load); ≤7% THD (Non-linear load)
Overload Capacity110%~150% maintain 30s then turn to bypass output; over 150% maintain 200ms110%~150% maintain 30s then turn to bypass output, over 150% maintain 200ms
Current Crest Ratio3:13:1
ConnectionsIEC320*4IEC320*6IEC320*6 IEC320*3&Terminal blockIEC320*3&Terminal block
EfficiencyTO Battery Mode83%83%
TO AC Mode85%85%
BatteryTypeSealed free maintenance lead acid batterySealed free maintenance lead acid battery
Nominal DC voltageBuilt in batteries 12V 7.0AH36VDCBuilt in batteries 12V7.0AH96VDC96VDC
Quantity 3 PCSDepend on requested back-up time8 PCSDepend on requested back-up time8 PCSDepend on requested back-up time
Back-up Time (Full Load)6minDepends on the capacity of                         external battery bank7minDepends on the capacity of external battery bank6minDepends on the capacity of                  external battery bank
Recharge Time5 hours to 90% of capacity full dischargeDepends on the capacity of external battery bank5 hours to 90% of capacity full dischargeDepends on the capacity of external battery bank5 hours to 90% of capacity full dischargeDepends on the capacity of external battery bank
Charge Current (MAX)1.0A5.0A/8.0A1.0 A5.0A/ 7.0A1.0 A5.0A/ 8.0A
Charge Voltage (VDC)41.1V±0.4V41.1V±0.4V110V±0.6V110V±0.6V110V±0.6V110V±0.6V
BypassAutomatic TransferOn overload and UPS failureOn overload and UPS failure
Before UPS Power-onDefault "ON" user adjustable to "YES"Default "ON" user adjustable to "YES"
Transfer Time 0ms; less than 4ms from inverter to bypass and vice versa0ms; less than 4ms from inverter to bypass and vice versa
IndicatorsLCD DisplayUPS status, Battery capacity, loading, Fault code                                                                          (LCD: I/P&O/P voltage&frequency, Battery voltage)UPS status, Battery capacity, loading, Fault code (LCD: I/P&O/P voltage&frequency, Battery voltage)
Audible Alarm Bypass,battery mode, Battery low, Overload, FaultBypass, battery mode, Battery low, Overload, Fault
Acoustic NoiseAt 1 Meter Distance<45dB<50dB
CommunicationsIntelligent RS232 serial portSoftware support Windows family software, Linux, Sun network operating system,IBM Aix, Compaq True64 SGI IRIX, FreeBSD, HP-UX and MACSoftware support Windows family software, Linux, Sun network operating system,IBM Aix, Compaq True64 SGI IRIX, FreeBSD, HP-UX and MAC
SNMP (Optional)Remote control UPS through SNMP management and InternetRemote control UPS through SNMP management and Internet
USB (Optional)Windows family software and Mac OSWindows family software and Mac OS
Network Surge Protection RJ45 I/O port available for network or FAX/ Telephone line/ ModemRJ45 I/O port available for network or FAX/Telephone line/Modem
EnvironmentalOperating Temperature0~40ºC0~40ºC
Operating Humidity20-90% (No condensing)20-90% (No condensing )
WeightNet Weight (kgs)11.005.5026.5027.0010.5011.00
UPS DimensionL*W*H (mm)370*145*220455*195*340
 
 MODELEX6KEX6KLEX10KEX10KLEX3110KEX3110KLEX3115KLEX3120KL
CapacityVA/W6000VA/4800W6000VA/4800W10KVA/8000W10KVA/8000W10KVA/8000W10KVA/8000W15KVA/12KW20KVA/16KW
InputNominal Voltage208/220/230/240VAC380VAC
Voltage Range120~275VAC210~475VAC
Frequency Range50/60Hz (Adjustable); 50Hz:46~54Hz ; 60Hz:56~64Hz50/60Hz (Adjustable); 50Hz:46~54Hz; 60Hz:56~64Hz
PhaseSingle phase with GroundThree phase (4 Wires+Ground)
Power Factor≥0.97≥0.95
OutputVoltage208/220/230/240*(1±1%) VAC208/220/230/240*(1±1%) VAC
Frequency50/60Hz (Adjustable)
50Hz AC Mode: Follow AC, Battery Mode: 50Hz  (1±0.2%)
60Hz AC Mode: Follow AC, Battery Mode: 60Hz (1±0.2%)
50/60Hz (Adjustable)
50Hz AC Mode: Follow AC, Battery Mode: 50Hz  (1±0.2%)
60Hz AC Mode: Follow AC, Battery Mode: 60Hz (1±0.2%)
Wave FormPure sine WavePure sine Wave
Power Factor0.80.8
Harmonic Distortion≤2% (Linear load); ≤6% (Non-Linear load)≤2% (Linear load); ≤6% (Nonlinear load)
Overload CapacityLoad<105% work consistant; 105%load<125% 1min; 125%≤load<150% 30secLoad<105% work consistant; 105%<load<125% 1min; 125%<load<150% 30sec
Current Crest Ratio3:13:1
ConnectionsTerminal blockTerminal block
EfficiencyBattery Mode87%87%
AC Mode88%85%
BatteryTypeSealed free maintenance lead acid batterySealed free maintenance lead acid battery
Nominal DC VoltageBuilt in batteries 12V7.0AH192 VDCBuilt in batteries 12V7.0AH192 VDC192 VDC
Quantity16 PCS16 PCS
Back-up Time(Full load)≥4 minutesDepends on requested Back-up time≥3 minutesDepends on requested Back-up timeDepends on requested Back-up time
Recharge Time7 hours to 90%Depends on capacity of external battery bank7 hours to 90%Depends on capacity of external battery bankDepends on capacity of external battery bank
Charge Current(Max)1.0 A4.5A1.0 A4.5A4.5A
Charge Voltage219.5Vdc±1%219.5Vdc±1%
BypassAutomatic TransferOn overload and UPS failureOn overload and UPS failure
Transfer Time ZeroZero
IndicatorsLCD DisplayUPS status, I/P&O/P voltage&frequency,Battery voltage, Battery capacity, Loading, Fault codeUPS status, I/P&O/P voltage&frequency, Battery voltage, Battery capacity, Loading, Fault code
Audible Alarm Bypass, battery mode, Battery low, Overload, FaultBypass, battery mode, Battery low, Overload, Fault
Acoustic NoiseAt 1 Meter Distance<55dB<55dB<60dB
CommunicationsIntelligent RS232 serial portWindows 98/NT/2000/XP/3000, Linux, Sun network , IBM Aix, Compaq True64 SGI IRIX, FreeBSD, HP-UX, MACWindows 98/NT/2000/XP/3000,Linux,Sun network ,IBM Aix, Compaq True64 SGI IRIX, FreeBSD, HP-UX ,MAC
SNMP (Optional)Power management from SNMP manager and web browserPower management from SNMP manager and web browser
USB (Optional)Windows family software and Mac OSWindows family software and Mac OS
EnvironmentalOperating Temperature0~40ºC0~40ºC
Operating Humidity20-90% (No condensation )20-90% (No Condensation )
WeightNet weight (kgs)59.0020.0060.5021.5065.0026.0035.0035.00
UPS DimensionL*W*H (mm)500*248*616500*240*490500*248*616

COMPANY SHOW:

FAQ:
Q 1. What's the payment terms and payment method ? 
A. We accept L/C, T/T, Credit Card, Western Union, Money Gram, etc.

Usually 30% deposit, 70% before shipment.

Q 2. How's the delivery time ?
A.  It  usually takes about 3-10 days after payment arrived.

Q 3. How about package ?
A. For the small UPS and the inverters less than 30kg will be packed in foams and cartons. For the big UPS and inverters heavier than 30kg will be packed in pallets or wood boxes .


Q 4. Would you accept to print our logo and design ?
A. Yes, we can print your logo on the inverters, UPS and cartons. Also welcomed your own design of these inverters and UPS.

Q 5. What kind of certificates you have ?
A. For company have ISO9001, ISO14001, TUV and SGS factory certification.

For UPS and power inverters, we have CE,IEC, KC and ETL, etc.

Q6. When the product have problem, how to solve it ?
A. We have a professional after-sales team, in case of any problems, first contact us to help you solve, we have a 24 months warranty and lifetime technical support. We will track product usage until you are satisfied.

Product Tag:
Related categories: