RO System Seawater Desalination (SWROL-8040)

Min.Order: 1
Product origin: Shanghai, China
Infringement complaint: complaintComplaint
US$ 70000 ~ 600000

Description
Ro System Seawater Desalination (SWROL-8040)
EWP SWROL-8040 series sea water systems have been engineered for capacities ranging from 5 m3/h to 50 m3/h for Sea water desalination design.



Benefits
1. Fully Equipped and Customizable
2. Skid Mounted
3. Components Easily Accessible
4. Pre-plumbed Wired and Assembled
5. Individually Test and Preserved
6. Low Operation and Maintenance Cost
7. Easy Maintenance and Servicing
8. 1-Year Limited Warranty



Standard Features
Membrane Elements and Housings
· Membrane model --- SW30-400
· Membrane manufacturer --- Filmtec
· Nominal rejection --- 97%-99%
· Housing --- FRP, 8inch, 1000psi, side port
· Housing manufacturer --- Firstline

Control System
· Siemens PLC
· Siemens HMI
· ABB VFD
· Parameter setting
· High pressure pump soft start
· Tank level control
· Feed water pump MCC and control reserved

Electrical Valve
· Valve body --- UPVC
· Actuator motor --- 220VAC or 24VDC

HP Pump and ERD
· Pump head inner wet contact --- SS2207
· Pump head (Case) --- SS2205
· Brand --- Danfoss

Instrument
· Digital flow meter --- Permeate, concentrate
· Conductivity meter --- Permeate
· pH meter --- Feed, permeate
· Pressure gauge --- Pre-filter, post-filter, pump discharge, concentrate
· Pressure switch --- Feed, concentrate
· Pressure transmitter --- Pre-filter, post-filter, HP pump discharge, concentrate

Connection Port
· Feed seawater inlet
· Fresh water inlet
· Permeate
· Drain
· Air release

Material of Construction
· High pressure piping --- SS2205
· Low pressure piping --- UPVC
· Frame --- SS304 with marine grade painting
· Control box --- IP54; SS304 with painting

Documentation Included
· Operation and maintenance manual
· Drawings: P&ID, electrical diagram, 3D

Options
· Containerized
· Feed water pump
· Feed water conductivity meter
· Communication: Modbus RTU
· Remote monitor and control
· Anti-scalant dosing unit
· SBS dosing unit
· ORP meter
· Clean-In-Place (CIP) system
· Pretreatment system

Specification
MODELSWROL-8040-12SWROL-8040-18SWROL-8040-24SWROL-8040-36SWROL-8040-42
Permeate rate ¹6-7 m³/hr9-0 m³/hr12-13.4 m³/hr18-21 m³/hr21-23.6 m³/hr
Approx. conc. rate8.6 m³/hr12.2 m³/hr16.4 m³/hr25.7 m³/hr28.9 m³/hr
Design Recovery 40-45%40-45%40-45%40-45%40-45%
Pump and Motor
ManufacturerDanfoss
ModelAPP8.2 APP10.2 APP13 APP22 APP24 
Motor HP22 KW30 KW37 KW55 KW55 KW
Pump head (case)SS2205
Pump head inner wet contactSS2207
Max. flow rate8.3 m³/hr10.5 m³/hr13.8 m³/hr21.9 m³/hr24.5 m³/hr
Max. Lubrication flow0.4 m³/hr0.4 m³/hr0.4 m³/hr0.9 m³/hr0.9 m³/hr
Energy Recovery  Device
ManufacturerDanfoss
ModeliSave21 plusiSave21 plusiSave21 plusiSave40iSave40
Quantity11111
Motor HP7.5 KW7.5 KW7.5 KW18.5 KW18.5 KW
Pump head (case)SS2205
Pump head inner wet contactSS2207
Allow flow rate range6-22 m³/hr6-22 m³/hr6-22 m³/hr21-41 m³/hr21-41 m³/hr
Max. Lubrication flow0.4 m³/hr0.4 m³/hr0.4 m³/hr0.9 m³/hr0.9 m³/hr
Membranes Elements and Housings
ManfacturerFirstline
Membrane quantity1218243642
Memb. housing style6-element long
Membrane housing array2 in parallel3 in parallel4 in parallel6 in parallel7 in parallel
Pre-filter (High-flow Cartridge)
ManufacturerFirstline
Filter housingET80-150S-20ET80-150S-40ET80-150S-40ET80-150S-60ET80-150S-60
PP Cartridge Length20"40"40"60"60"
Filter housing Qty.
(1st stage)
11111
Filter housing Qty.
(2nd stage)
11111
Capacity/each cartridge15-25 m3/hr30-50 m3/hr50-70 m3/hr50-70 m3/hr50-70 m3/hr
Valves
Sea water motorized inlet valve2" UPVC; butterfly2.5" UPVC; butterfly3" UPVC; butterfly4" UPVC; butterfly4" UPVC; butterfly
Fresh water motorized valve2" UPVC; butterfly2.5" UPVC; butterfly3" UPVC; butterfly4" UPVC; butterfly4" UPVC; butterfly
Concentrate valve1.5" UPVC; diaphragm;
adjustable
2" UPVC; diaphragm;
adjustable
2" UPVC; diaphragm;
adjustable
3" UPVC; diaphragm;
adjustable
3" UPVC; diaphragm;
adjustable
Installation 
Inlet2" Flange2.5" Flange3" Flange4" Flange4" Flange
Permeate1.5" Flange2" Flange2" Flange2.5" Flange3" Flange
Drain1.5" Flange2" Flange2" Flange3" Flange3" Flange
Package Dimension
Approx. Height1900mm1900mm2100mm2100mm2100mm
Approx. Width6900mm6900mm6900mm6900mm6900mm
Approx. Depth1100mm1100mm1400mm1700mm1700mm
Approx. Shipping Weight1200kg1400kg1700kg2000kg2400kg
Options
Feed water pump16 m3/hr @ 4bar24 m3/hr @ 4bar32 m3/hr @ 4bar48 m3/hr @ 4bar55 m3/hr @ 4bar
Antiscalant Dosing UnitMetering pump:  0.95 L/h
Chemical tank: 200-300L
Metering pump:  2.57 L/h
Chemical tank: 200-300L
Metering pump:  2.57 L/h
Chemical tank: 300-500L
Metering pump:  2.57 L/h
Chemical tank: 300-500L
Metering pump:  4.2 L/h
Chemical tank: 300-500L
CIP systemCIP tank: 1000L         
CIP pump: 20m³/[email protected]       
CIP filter:  BF-1-2 
CIP tank: 1000L         
CIP pump: 30m³/[email protected]       
CIP filter: BF-1-2 
CIP tank: 1500L         
CIPpump: 40m³/[email protected]       
CIP filter: BF-1-2 
CIP tank: 2000L         
CIPpump: 60m³/[email protected]       
CIP filter: BF-1-2 * 2
CIP tank: 3000L         
CIPpump: 70m³/[email protected]       
CIP filter: BF-1-2 * 2
Pretreatment: PTMC series  PTMC-160PTMC-160PTMC-160 * 2PTMC-160 * 2PTMC-160 * 3
MODELSWROL-8040-48SWROL-8040-54SWROL-8040-72SWROL-8040-90SWROL-8040-96
Permeate rate ¹24-25.8 m³/hr27-30.7 m³/hr36-42 m³/hr45-51.5 m³/hr48-55 m³/hr
Approx. conc. rate31.5 m³/hr37.5 m³/hr45.8 m³/hr63 m³/hr67.2 m³/hr
Design Recovery 40-45%40-45%40-45%40-45%40-45%
Pump and Motor
ManufacturerDanfoss
ModelAPP26 APP30 APP38/46 APP53 APP53/65 
Motor HP75KW75KW90/110KW132KW132/160KW
Pump head (case)SS2205
Pump head inner wet contactSS2207
Max. flow rate26.7 m³/hr31.6 m³/hr39 m³/hr53 m³/hr53 or 67.3 m³/hr
Max. Lubrication flow0.9 m³/hr0.9 m³/hr1.5 m³/hr1.5 m³/hr1.5 m³/hr
Energy Recovery  Device
ManufacturerDanfoss
ModeliSave40iSave40iSave50iSave70iSave70
Quantity11111
Motor HP11 KW11 KW18.5 KW18.5 KW18.5 KW
Pump head (case)SS2205
Pump head inner wet contactSS2207
Allow flow rate range21-41 m³/hr21-41 m³/hr42-52 m³/hr50-70 m³/hr50-70 m³/hr
Max. Lubrication flow0.9 m³/hr0.9 m³/hr1.5 m³/hr1.5 m³/hr1.5 m³/hr
Membranes Elements and Housings
ManfacturerFirstline
Membrane quantity4854729096
Memb. housing style6-element long
Membrane housing array6 in parallel9 in parallel12 in parallel15 in parallel16 in parallel
Pre-filter (High-flow Cartridge)
ManufacturerFirstline
Filter housingET80-150S-80ET80-150S-60ET80-150S-60ET80-150S-60ET80-150S-60
PP Cartridge Length80"60"60"60"60"
Filter housing Qty.
(1st stage)
12233
Filter housing Qty.
(2nd stage)
12233
Capacity/each cartridge70-110 m3/hr50-70 m3/hr50-70 m3/hr50-70 m3/hr50-70 m3/hr
Valves
Sea water motorized inlet valve4" UPVC; butterfly5" UPVC; butterfly5" UPVC; butterfly6" UPVC; butterfly6" UPVC; butterfly
Fresh water motorized valve4" UPVC; butterfly5" UPVC; butterfly5" UPVC; butterfly6" UPVC; butterfly6" UPVC; butterfly
Concentrate valve3" UPVC; diaphragm;
adjustable
4" UPVC; diaphragm;
adjustable
4" UPVC; diaphragm;
adjustable
5" UPVC; diaphragm;
adjustable
5" UPVC; diaphragm;
adjustable
Installation 
Inlet4" Flange5" Flange5" Flange6" Flange6" Flange
Permeate3" Flange3" Flange4" Flange4" Flange4" Flange
Drain3" Flange4" Flange4" Flange5" Flange5" Flange
Package Dimension
Approx. Height2100mm2100mm2100mm2400mm2100mm
Approx. Width6900mm6900mm6900mm6900mm6900mm
Approx. Depth1700mm2000mm2000mm2000mm2300mm
Approx. Shipping Weight2700kg3000kg3200kg4000kg4200kg
Options
Feed water pump60 m3/hr @ 4bar70 m3/hr @ 4bar90 m3/hr @ 4bar115 m3/hr @ 4bar125 m3/hr @ 4bar
Antiscalant Dosing UnitMetering pump:  4.2 L/h         
Chemical tank: 300-500L
Metering pump:  4.2 L/h         
Chemical tank: 300-500L
Metering pump:  7.6 L/h         
Chemical tank: 500-800L
Metering pump:  7.6 L/h         
Chemical tank: 500-800L
Metering pump:  7.6 L/h         
Chemical tank: 500-800L
CIP systemCIP tank: 3000L         
CIP pump: 80m³/[email protected]       
CIP filter:  BF-1-2 * 2
CIP tank: 3000L         
CIP pump: 90m³/[email protected]       
CIP filter: BF-1-2 * 3 
CIP tank: 4000L         
CIPpump: 120m³/[email protected]       
CIP filter: BF-1-2 *3 
CIP tank: 2000L         
CIPpump: 150m³/[email protected]       
CIP filter: BF-1-2 * 4
CIP tank: 5000L         
CIPpump: 160m³/[email protected]       
CIP filter: BF-1-2 * 4
Pretreatment: PTMC series  PTMC-160 * 3PTMC-160 * 3PTMC-160 * 4PTMC-160 * 5PTMC-160 * 6
1 Maximum permeate rate listed at temperature 25ºC, permeate rate will decrease with temperature decreasing.

Operating Limits
Maximum Feed Temperature              °C (°F)35 (95)pH (Continuous)4 ~ 9
Minimum Feed Temperature               °C (°F)5 (41)Minimum pH (Continuous)4
Maximum Feed Pressure                   bar (psi)5 (72)Free Chlorineundetectable
Minimum Feed Pressure                    bar (psi)2 (29)Iron                                         ppm<0.1
Feed TDS                                            ppm35000Manganese                              ppm<0.05
SDI<5Organic matter                         ppm<1

Product Pictures


Loading Pictures




About EWP

Founded in 2004, EWP is an international group with diversified cultures. We have members in USA, South Africa, Nigeria,Malaysia, and China.

Through international networks around the world, we are able to provide a variety of water treatment products from residential, commercial and industrial components as well as systems. 

EWP is also capable of providing many kinds of non-water treatment products such as toilet paper making machine, bottle filling machine, liquid packing machine, and so forth.We can help source and meet customers' need in every possible way.

EWP is aimed at a better quality standard environment by supplying water treatment-related products. EWP hopes to establish a better living standard for the present and in the future.

Product Tag:
Related categories:
Scroll to Top