Contec Ms400 Medical Diagnosis Equipment Multi-Parameter Patient Simulator

Min.Order: 1
Product origin: Qinhuangdao, Hebei, China
Infringement complaint: complaintComplaint
US$ 200 ~ 300

Description
Multi-Parameter Patient Simulator Portable Ultrasound Medical Diagnosis Equipment
 

Product Description


Model:MS400           Brand:CONTEC



Introduction
MS400 Multiparameter Simulator(ECG simulator) is a portable device, can simulate accurately 12-lead ECG, Respiration, Temperature,2-channel IBP or 4-channel IBP, the default is 4-channel IBP. 
ProjectNameDescription
1IBP1 port Used to connect IBP1 cable plug. (Refer to "IBP Line Orders")
2IBP2 port Used to connect IBP2 cable plug. (Refer to "IBP Line Orders")
3IBP3 port Used to connect IBP3 cable plug. (Refer to "IBP Line Orders")
4IBP4 port Used to connect IBP4 cable plug. (Refer to "IBP Line Orders")
5C.O./TEMP portThe port is temperature port at present.
Note: if you use this port, plugged the body temperature cables before turned on the simulator.
6USB port Reserved port 
7Reset portSwitch the simulator.
8TF portPlug SD card.
Note: If use the SD card, you need to put the SD card into the simulator before turning it on. 
9Equivalent power jackAccording to the instructions of our company's power supply.
1010-lead jacksOutput to 10 Universal ECG Jacks, color-coded to AHA and IEC Standards.
LabelMeaning
RA or R Right arm
LA or LLeft arm
RL or N Right leg(reference or grounded)
LL or FLeft leg
V1, V2, V3, V4, V5 and V6 V Leads (U.S. and Canada), also referred to as pericardial, precordial or unipolar chest leads.
C1, C2, C3, C4, C5 and C6Chest leads (International)
11The indicator light
 of charging
Charge indicator light is red : AC power supply / charging. Green : full electricity.
Red and flashing: battery low.
12DisplayThe display shows the selected code, the meanings of the code, the waveforms, the list of the functions, System Setting and so on.
13KeysThere are two kinds of keys: the numeric keys and function keys. 
0View the current settings.
1Normal sinus rhythm, 80BPM, 1mV.
2Set the ECG Rate: 15, 20, 25, 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300, 320, 340 and 350 BPM.
3Set amplitude: 0.5, 1.0, 1.5 and 2.0 mV.
4Set the respiratory Rate: 0 (Apnea), 15, 20, 30, 40, 60, 80,100, 120 and 150 R/MIN.
5Set the baseline impedance : 500, 1000, 1500 and 2000Ω.
6Set the respiratory impedance : 0.2, 0.5, 1.0 and 3.0 Ω.
7Channel 1, 2,3 and 4 will be reset to 0.
8Set all the channels as IBP waveform.
9Set all the channels as static-pressure level.
14Control keys  
Up and down keysWhen select a key which can adjust a setting, you can click the up and down keys to adjust it.
Left and right keysSwitch the pages and browse the codes.
EnterDetermine the choice.
CLEARCancel the current selection, select the code again.
On/OffLong press the key to turn on or turn off the simulator.
 

Main Features
ECG:
1.Conventional: All leads have the same voltage with the II-lead as the reference
2.Amplitude: 0.5, 1.0, 1.5 and 2.0mV
3.ECG Rate: 15, 20, 25, 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300, 320, 340 and 350 BPM
4.ECG artifacts: 50 and 60 Hz, muscle, baseline and breathing
5.The elevation of the ST segment: +0.8 to -0.8 mV, the step is 0.1 mV

Arrhythmia:
1.ATRIAL: Atrial Fib(coarse), Atrial Fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial Tachycardia, Nodal Rhythm, Supraventricular Tachycardia
2.Ventricular: Vent Fib (coarse), Vent Fib (fine), Premature Ventricular Contraction (PVC) 6/min, PVCs 12/min, PVCs 24/min, Frequent Multifocal, Bigeminy, Trigeminy, Paired PVCs, Run 5 PVCs, Run 11 PVCs, Vent Tachycardia, Asystole
3.Premature Beat: Atrial Premature Atrial Contraction (PAC), Nodal PAC, Left Ventricular Focus PVC1, Early Left Ventricular Focus PVC1, R on T Left Ventricular Focus, Right Ventricular Focus PVC2, Early Right Ventricular Focus PVC2, R on T Right Ventricular Focus, Multifocal PVC
4.Conduction Defects: First Degree Heart Block, Second Degree Heart Block, Third Degree Heart Block, Right Bundle Branch Block, Left Bundle Branch Block


Four IBP Channels:
1.The default: 00/00mmHg
Dynamic IBP(unit: mmHg)
Channel 1: Artery 120/80, Radial 120/80, Left Ventricle 120/00, Right Ventricle 25/00
Channel 2: Artery 120/80, Radial 120/80, Left Ventricle 120/00, Right Atrium(CVP) 15/10, Right Ventricle 25/00, P-ulmonary Artery 25/10, Pulmonary Wedge  10/2, Left Atrium 14/4
Channel 3: Artery 120/80, Radial 120/80, Left Ventricle 120/00, Right Atrium(CVP) 15/10, Right Ventricle 25/00, P-ulmonary Artery 25/10, Pulmonary Wedge 10/2, Left Atrium 14/4
Channel 4:
1.Auto Swan-Ganz (every 15 seconds): RA(CVP), RV, PA, PAW (Pulmonary Wedge)
2.Man Swan-Ganz: press ENTER key to change every time
3.Static-Pressure Levels
Channel 1: 0, 80, 160, 240, 320 and 400mmHg
Channel 2: 0, 50, 100, 150, 200 and 250mmHg
Channel 3: 0, 20, 40, 60, 80 and 100mmHg
Channel 4: P4 tracks the static pressure levels of P3

Respiration:
1.Respiration Rate: 0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 and 150 R/MIN
2.Impedance: 0.2, 0.5, 1.0 and 3.0 Ω
3.Baseline impedance: 500, 1000, 1500, 2000Ω
4.Apnea: 12 s, 22 s, 32 s

Temperature:
Four temperature: 0ºC(32°F), 24ºC( 75°F), 37ºC(98.6°F), 40ºC(104°F)

Simulate the signal of square,triangle, pulse and sine with adjustable frequency.
Simulate the pacemaker signal.
Simulate the signal of standard ECG calibration.
Including the ECG waveforms of ANSI/AAMI EC13.
 
ItemQuantity
Standard components:
User Manual (print version)1
15V adapter or 9V adapter ( USA Porduction)1
Optional Accessories:
Temperature Cable1
IBP Cable1
Case Convertion Software and Operating Introduction1
For more information, please contact your local dealer.
 