Handheld Annimal Pulse Oximeter Clinical Analysis Instrument

Min.Order: 1
Product origin: Qinhuangdao, Hebei, China
Infringement complaint: complaintComplaint
US$ 50 ~ 80

Description
Handheld Annimal Pulse Oximeter Clinical Analysis Instrument
 

Product Description


Model:CMS60D-VET   Brand:CONTEC

Instructions

Principle of the CMS60D-VET Handheld Veterinary/Animal Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology,The Veterinary Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through animal's tongue or ear and so on.The product is suitable for being used in family,pet hospital and etc. (Handheld Veterinary/Animal Pulse Oximeter is recommended to use the device when the animal is still.)
 
Major Features

1.Small in volume,light in weight and convenient in carrying
2.Operation of the product is simple, low power consumption
3.Operation menu for the function setting
4.SpO2 value display
5.Pulse rate value display, bar graph display
6.Pulse waveform display
7.Screen brightness can be changed
8.Pulse rate sound indication
9.With review function
10.With clock function
11.With measured data overruns limits and low-voltage alarm function
12.Battery capacity indication
13.Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage ,and with alarm function
14.With SpO2 value and pulse rate value of storage, the storage data can be uploaded to computers
15.Real-time data can be transmitted to computers
16.Connected with an external oximeter probe


Main performance
 
Display Mode1.8" Color OLED display
Screen Resolution160*128
SpO2 Measuring Range0%~100%(the resolution is 1%)
Accuracy: 70%~100%±2%, Below 70% unspecified
PR Measuring Range30bpm~250bpm(the resolution is 1bpm)
Accuracy:±2bpm or ±2% (select larger)
Measurement Performance in Weak Filling ConditionSpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to surrounding lightThe deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
Power Consumptionless than 100mA
VoltageDC 2.6V~3.6V
Power SupplyDry battery(2AA)
Battery working hourThe theoretical number is 44 hours.
Safety TypeInterior Battery, BF Type


Accessories
 
1.Sell in standard
2.A user manual
3.A data line
4.A disk (PC software)
5.An oximeter probe for animal


Physical Identity
-Dimension:110(L) × 60(W) × 23(H) mm
-Weight:About 120g (with Dry battery(2AA))

 

Detailed Photos


 

Product List


-TELEMEDICINE products

-Pulse oximeter
-Patient Monitoring
-ECG machine(Electrocardiograph)/Holter ECG/Stress test ECG,
-EEG,
-Ultrasound Imaging,Pocket fetal doppler,fetal monitor,
-Blood pressure Monitor(ABPM),
-spirometer
-infusion/syringe Pump
-Digital Stethscope
-In-Vitro Diagnostics
-simulator
-Veterinary products

View more products,click here...

Company Profile



Scroll to Top