Specification for 60Hz FOTON generator |
Gen-set model | GF2-20KW |
Prime output (KW/KVA) | 20/25 |
Standby output (KW/KVA) | 22/27.5 |
Engine model | 4JB1 |
Rated output (KW) | 28 |
Standby output (KW) | 31 |
Engine speed (rpm) | 1800rpm |
Engine characters | Water-cooling, in line, Vertical, 4 stroke, direction injection |
Air induction system: | Natural Aspiration |
Bore (mm) X Stroke (mm) | 93 X 102 |
Cubic capacity (L) | 2.771 |
Piston speed (m/s) | 6.12 |
Compression ratio | 18.2: 1 |
Speed stability bandwidth | ≤ ± 0.8% |
Steady governing rate | ≤ 5% |
Exhaust temperature | 550 |
Exhaust back pressure | 15KPa |
Lube temperature/capacity | 120/5.5L |
BMEP: Kpa (prime power) | 746 |
Heat rejection to cooling | 27.1kw/min |
Cooling system volume | 4.5L (except water tank) |
Cooling air flow | 118m 3 /min |
Combustion air flow | 2.56m 3 /min |
Exhaust gas flow | 7.97m 3 /min |
Rating fuel consumption (L/h) | 6.5 |
Alternator model | 184F |
Type | Copy Stamford brushless |
Prime output (KW/KVA) | 20KW/25KVA |
Standby output (KW/KVA) | 22KW/27.5KVA |
Phase, voltage, frequency | Single phase, 220V, 60Hz |
Voltage adjustment | ≤ ± 5% |
Insulation class | H |
Package | Plywood case |
Dimension (LXWXH) mm | 1800*770*1100 |
Gross weight (KGS) | 900 |
Fuel tank capacity(L) | |
20FT/PCS | 18 |
| |
Specification for 60Hz FOTON generator |
Gen-set model | GF2-25KW |
Prime output (KW/KVA) | 25/31 |
Standby output (KW/KVA) | 27.5/34.5 |
Engine model | 4JB1 |
Rated output (KW) | 28 |
Standby output (KW) | 31 |
Engine characters | Water-cooling, in line, Vertical, 4 stroke, direction injection |
Air induction system: | Natural Aspiration |
Engine speed (rpm) | 1800rpm |
Bore (mm) X Stroke (mm) | 93 X 102 |
Cubic capacity (L) | 2.771 |
Piston speed (m/s) | 6.12 |
Compression ratio | 18.2: 1 |
Speed stability bandwidth | ≤ ± 0.8% |
Steady governing rate | ≤ 5% |
Exhaust temperature | 550 |
Exhaust back pressure | 15KPa |
Lube temperature/capacity | 120/5.5L |
BMEP: Kpa (prime power) | 746 |
Heat rejection to cooling | 27.1kw/min |
Cooling system volume | 4.5L (except water tank) |
Cooling air flow | 118m 3 /min |
Combustion air flow | 2.56m 3 /min |
Exhaust gas flow | 7.97m 3 /min |
Rating fuel consumption (L/h) | 6.5 |
Alternator model | TFW-20KW |
Type | Copy stamford brushless |
Phase, voltage, frequency | Single phase, 220V, 60Hz |
Voltage adjustment | ≤ ± 5% |
Insulation class | H |
Package | plywood case |
Dimension (LXWXH) mm | 1800*770*1100 |
Gross weight (KGS) | 900 |
Fuel tank capacity(L) | |
20FT/PCS | 18 |
| |
Gen-set model | GF2-32KW |
Prime output (KW/KVA) | 32/40 |
Standby output (KW/KVA) | 34/42.5 |
Engine model | 4JB1T |
Rated output (KW) | 34 |
Standby output (KW) | 37 |
Engine characters | Water-cooling, in line, Vertical, 4 stroke, direction injection |
Air induction system: | Turbocharged |
Engine speed (rpm) | 1800rpm |
Bore (mm) X Stroke (mm) | 93 X 102 |
Cubic capacity (L) | 2.771 |
Piston speed (m/s) | 6.12 |
Compression ratio | 18.2: 1 |
Speed stability bandwidth | ≤ ± 0.8% |
Steady governing rate | ≤ 5% |
Exhaust temperature | 550 |
Exhaust back pressure | 15KPa |
Lube temperature/capacity | 120/5.5L |
BMEP: Kpa (prime power) | 890 |
Heat rejection to cooling | 30.7kw/min |
Cooling system volume | 4.5L (except water tank) |
Cooling air flow | 118m 3 /min |
Combustion air flow | 3.08m 3 /min |
Exhaust gas flow | 9.53m 3 /min |
Rating fuel consumption (L/h) | 6.5 |
Alternator model | TFW-20KW |
Type | Copy stamford brushless |
Phase, voltage, frequency | Single phase, 220V, 60Hz |
Voltage adjustment | ≤ ± 5% |
Insulation class | H |
Package | plywood case |
Dimension (LXWXH) mm | 1800*770*1100 |
Gross weight (KGS) | 900 |
Fuel tank capacity(L) | |
20FT/PCS | 18 |