Indoor Fire Security Sensorial Alarm Solution Equipment System

Min.Order: 1
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ 60 ~ 525

Description





Indoor Fire Security Sensorial Alarm Solution Equipment System
Key Descriptions:
1. R&D based 4 on EN54 part 2 & standard
2. Modularized design & flexible extendable capacity.
3. Two-level control mode by to Lock
4.27VDC power supply output.
5. FIRE PROTECTION, signal FIRE ROUTING and FAULT output, the output dog sees configured to dry relay type or wet sources type.
6.2 channel general sounders output.
7. Each zone there are 1 circuit detectors input.
8. Each zone dog sees disable by button.
9. RESET button to reset the panel
10. SILENCE button to stop BUZZER and SOUNDERS.
11. EVACUATE button to start to manual fire alarm immediately.
12. TEST button to test all LEDs normally.
13. Low-battery protection function, when battery voltage to lower than 21VDC, battery will sees cut off automatically until the mains power is on.
14. Optional GSM modulates is available for fire alarm by SMS.




 
ITEM1Zone panel2Zone panel4-8 Zone panel12-32 Zone panel
Model no. AW-CFP2166-01AW-CFP2166-02AW-CFP2166-04-8AW-CFP2166-12-32
Power specification
 
Mains supply voltage110VAC or 240VAC
Internal to power supply27.2VDC
Total output current limited500mA @ 240VAC500mA @ 240VAC3A @ 240VAC3A @ 240VAC
Main supply for monitor faultYES
Battery protection for low voltageYES
Batteries (default configuration)12V2AH*2
Detector circuit specification
 
Number of circuit124-164-32
Line fault for monitor open circuitYES
Line fault for monitor short circuitYES
Line fault for monitor removal detectorYES, if End of Line Unit Monitor fitted in pleases of End of Line Resistor
End of Line device6.8k Ω, 5% tolerance, 0.25W (color code-blue, congregation, network, gold)
Detector continuity diodesSilicone 1N4001 or Schottky type (required if End of Line Unit Monitor fitted to give Detector Removal Fault)
Call point resistor VALUE470 to 680 Ω, 0,225 or 0,5 watt
Maximum to number of smoke/heat detectors Rep zone20 (based on to total detector current of 2mA, each detector consuming 100μA). It notices: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts
Maximum to number of manual call points Rep zoneNot limit
Sounder circuit specification
 
General Number of circuits2
End of line resistor VALUE6.8k Ω, 5% tolerance, 0.25W (color code-blue, congregation, network, gold)
Line fault for monitor open circuitYES
Line fault for monitor short circuitYES
Outputs fused AT400mA
Maximum number of bells @ 20mA of each sounder output20
Fuses
 
Battery fuse1.5A F 20mm
Sounder outputs500mA F 20mm
Fire and fault output
 
Output typeNC and nonrelay
Maximum current100mA
Connection block
 
Conductive acceptable Largest size2.5mm2
Conductive acceptable Smallest size0.75mm2
Size and weight
 

 
Dimensions (mm)272*200*70mm320*231*90mm395X502X124362X565X124
Weight (without batteries)4kg5kg7kg8kg
Weight (with batteries)5.8kg6.8kg9.6kg12.5kg

Our company

Asenware, to manufacturer of fire alarm and fire suppression system since 2005. Our to headquarter is in London, UK, with factory Shenzhen, China
For We keep our best service our customers, and have to rich experienced to engineer team to design and install for overseas projects.



Product range:
1. Addressable fire alarm system (FP100 series, 2189.2100 series)
2. Conventional fire alarm system (2166 series)
3. FM200 gas fire suppression system
4. Emergency light system
5. Fire pump system
6. Fire hose and fire hose reel cabinet