Capacité | t | 0.025/0.05/0.1/0.15/0.2/0.25/0.3/0.5/0.6/0.75/1/1.5/2/2.5/3/5/7.5/10/15/20/30 | ||||||
lb | 100/200/250/300/500/750/1K/1.5K/2K/2.5K/3K/5K/10K/15K/20K | |||||||
Précision | C2 | C3 | C4 | A5S | A5M | B10S | B10M | |
Approbation | OIML R60 C3 | OIML R60 C4 | ||||||
Maximum nombre de vérification intervalles | n max | 2000 | 3000 | 4000 | 5000 | 5000 | 10000 | 10000 |
Minimum cellule de charge vérification intervalle | v min | Emax /5000 | Emax /10000 | Emax /14000 | Emax /15000 | Emax /15000 | Emax /10000 | Emax /10000 |
Combiné erreur | %FS | ≤±0.030 | ≤±0.020 | ≤±0.018 | ≤±0.018 | ≤±0.026 | ≤±0.035 | ≤±0.050 |
Vitesse rampante | %FS /30min | ≤±0.024 | ≤±0.016 | ≤±0.012 | ≤±0.012 | ≤±0.017 | ≤±0.030 | ≤±0.040 |
Température effet sensibilité on | %FS/10ºC | ≤±0.017 | ≤±0.011 | ≤±0.009 | ≤±0.009 | ≤±0.013 | ≤±0.030 | ≤±0.040 |
Température effet sur zéro | %FS/10ºC | ≤±0.023 | ≤±0.015 | ≤±0.010 | ≤±0.010 | ≤±0.014 | ≤±0.030 | ≤±0.020 |
Sortie sensibilité | mv/v | 2.0±0.004 (métrique) 3.0±0.008 (impérial) | ||||||
Entrée résistance | Ω | 350±3.5 | ||||||
Sortie résistance | Ω | 351±2.0 | ||||||
Isolation résistance | MΩ | ≥ 5000 (50 V C.C.) | ||||||
Solde nul | %FS | 1.5 (métrique) 1.0 (impérial) | ||||||
Température, compensé | ºC | -10~+40 | ||||||
Température, fonctionnement | ºC | -35~+65 | ||||||
Excitation, Recommandé | V | 5 À 12 (C.C.) | ||||||
Excitation, Max | V | 18 (DC) | ||||||
Coffre-fort surcharge | %FS | 150 | ||||||
Surcharge ultime | %FS | 300 |