2023 China Energy Save Industry Rooftop Air Conditioner

Min.Order: 1
Product origin: Shanghai, China
Infringement complaint: complaintComplaint
US$ 3500 ~ 3660

Description



Rooftop air conditioner

Features

Description:
1. Air cooled rooftop air conditioner.
2. Cooling capacity: 8kw to 90kw, a variety of choices.
3. High external pressure.
4. Applicable to residential and commercial buildings, hotels, and scientific research units, factories and enterprises and so on.


Feature:

1. Evaporator: Type Inner grooved copper tube and aluminum fin
2. Fin Type 5* :Slotted fin hydrophilic aluminum fin
3. Condenser: Type Inner grooved copper tube and aluminum fin
4. Fin Type 5* :Rippled hydrophilic aluminum fin
5. Condenser Fan Type: Low noise axial type

 

Technical Data

  GT-WKR Series-Roof Top AH Specifiaction 1

 

Model   GT-WKR-

10

15

18

20

25

30

35

 
 

Specification

Cooling capacity 1*

kW

10.5

15.0

18.5

21.0

26.3

29.8

35.0

 

Heating capacity 2*

kW

11.5

15.9

19.5

22.1

27.6

32.6

37.1

 

Supply air 3*

m3/h

1800

2400

2900

3500

4500

5000

5800

 

Static pressure 3*

Pa

100

150

150

180

200

250

250

 

Noise 4*

dB(A)

60

60

62

62

65

65

68

 

Power

3N-380V-60Hz

 

Total capacity

3.9

5.74

7.0

8.27

9.96

11.0

14.15

 

Color

White

 

ooling system

Compressor

Type

Efficient scroll closed

 

Quantity

1

1

1

1

1

1

2

 

Supply air fan

Type

Low noise centrifugal type

 

Capacity

kW

0.37

0.55

0.75

0.75

1.1

1.5

2.2

 

Evaporator

Type

Inner grooved copper tube and aluminum fin

 

Fin type 5*

Slotted fin hydrophilic aluminum fin

 

Condenser

Type

Inner grooved copper tube and aluminum fin

 

Fin type 5*

Rippled hydrophilic aluminum fin

 

Condenser fan

Type

Low noise axial type

 

Quantity

1

1

1

1

1

1

2

 

Refrigerant

Refrigerant

R22/R407C

 

Refrigerant control

External balance type thermal expansion valve

 

Air filter

Initially effect plate filter

 

Dimensions

L

mm

1400

1400

1600

1600

1850

1850

2200

 

W

mm

1050

1050

1200

1200

1400

1400

1800

 

H

mm

1050

1050

1050

1050

1200

1200

1520

 

Weight

kg

200

230

260

300

550

600

850

 
  1. 1.  Cooling condition: Indoor dry bulb/wet bulb:29/19ºC,Outdoor dry bulb/wet bulb:46/24ºC
  2. 2.  Heating condition:Indoor dry bulb/wet bulb:20/-ºC;outdoor dry bulb/wet bulb:7/6ºC;
  3. 3.  The air volume and static pressure`s specification in the table is standard, and can be designable.

4. Noise data is measured in the front of the units when cooling under the standard air volume.

5. Fin type and material can be designable.

  GT-WKR Series-Roof Top AH Specifiaction 1

 

Model   GT-WKR-

40

50

60

70

90

110

120

 
 

Specification

Cooling capacity 1*

kW

42.0

52.8

61.2

70.2

87.5

105.1

122.5

 

Heating capacity  2*

kW

44.1

55.4

62.5

73.8

92.8

112.0

130.0

 

Supply air 3*

m3/h

7000

8600

10000

12000

14500

17000

20000

 

Static pressure 3*

Pa

300

300

300

350

350

400

400

 

Noise 4*

dB(A)

68

69

69

70

71

72

72

 

Power

3N-380V-60Hz

 

Total capacity

17.24

20.72

23.0

29.76

39.1

44.66

51.58

 

Color

White

 

cooling system

Compressor

Type

Efficient scroll closed

 

Quantity

2

2

2

2

2

4

4

 

Supply air fan

Type

Low noise centrifugal type

 

Capacity

kW

2.2

3

4

4

5.5

7.5

7.5

 

Evaporator

Type

Inner grooved copper tube and aluminum fin

 

Fin type 5*

Slotted fin hydrophilic aluminum fin

 

Condenser

Type

Inner grooved copper tube and aluminum fin

 

Fin type 5*

Rippled hydrophilic aluminum fin

 

Condenser fan

Type

Low noise axial type

 

Quantity

2

2

2

4

4

4

4

 

Refrigerant

Refrigerant

R22/R407C

 

Refrigerant control

External balance type thermal expansion valve

 

Air filter

Initially effect plate filter

 

Dimensions

L

mm

2200

2600

2600

3200

3200

6000

6000

 

W

mm

1800

2200

2200

2200

2200

2300

2300

 

H

mm

1520

1700

1700

1900

1900

2300

2300

 

Weight

kg

850

1100

1250

1400

1650

1850

2200

 


Note:
1. Cooling condition: Indoor dry bulb/wet bulb:29/19ºC,Outdoor dry bulb/wet bulb:46/24ºC
2. Heating condition:Indoor dry bulb/wet bulb:20/-ºC
;outdoor dry bulb/wet bulb:7/6ºC;
3. The air volume and static pressure`s specification in the table is standard, and can be designable.
4. Noise data is measured in the front of the units when cooling under the standard air volume.
5. Fin type and material can be designable.



Our cases


factory


 

 

 rooftop air conditioner sample policy:

1. We charge for samples. If we have the samples you need in stock, we can send it to you within one week after received payment.

 

2. We can also manufacture samples according to your drawings or samples; lead time depends on the actual production status in our factory.

 

Choose Us; Do Not Hesitate:

1) We can help buyers design specific products or produce products according to buyers' design 

2) We can print logo according to buyers' requirement

3) We has exported to many countries,such as Korea, USA, German, Canada etc.

4) Design term:We have professional design team.

5) Professional factory: We are manufacturer, specializing in manufacturing heat exchangers for over 10 years, competitive price with good quality.

6)Large productivity: 2000opcs per month.
7)Rapid response to your needs: We will reply within 24 hours after receiving you letter. If you have urgent thing, welcome to call us.

8)The Most Efficient Service, Best Quality and Excellent Reputation.

Contact us

Diana Han



Shanghai Venttech M&E Technology Co.,Ltd 

 
 
 
 

 
Web: cnventtk.en.made-in-china.com
Scroll to Top