High Accuracy CT PT Transformer Tester CT Meter PT Tester

Min.Order: 1
Product origin: Chongqing, China
Infringement complaint: complaintComplaint
US$ 6000

Description


Introduction:

High Accuracy CT PT Transformer Tester CT Meter PT Tester is an all in one solution for testing all type of CT/PT as per IEC standards. It is an equipment with high return on investment. Below features make CT PT Parameter Analyzer an ideal choice for measuring current transformers and potential  transformers: 

 

  1. Low Testing Time (Completes all  test for CT/PT Winding & Cores in a few min)

  2. Simple connection (Simple one time connection)

  3. Highest  Accuracy (0.02% for typical, 0.1% for guaranteed)

  4. Portable & Light Weight 

  5. High Interference Rejection (Can be used in 220/400/765 KV  Live Switchyards )

 

Specifications:

GDVA-405 High Accuracy CT PT Transformer Parameter Analyzer
1Test standardsIEC60044-1, IEC60044-2, IEC60044-5, IEC60044-6, IEC61869 and C57.13
2Power supplyAC220V±10%,50Hz/60Hz±10%
3Power output0.1~180V (AC)
4Current output0.001~5A(RMS)
5Power output500VA
6Max. knee voltage measurement60kv
7Current measurement range0~10A (automatically change range in 0.1/0.4/2/10A)
8Current measurement error<±0.1%+0.01%FS
9Voltage measurement range0~200 V (automatically change range in 1V/10V/70V/200V)
10Voltage measurement error< ±0.1%+0.01%FS
11Turns ratio measurement range1~30000;
1~2000 error<0.05%; 2000~5000 error>0.1%; 5000~35000 error<0.2%
12Phase measurementerror:±2min,resolution:0.01min
13Coil resistance measurementRange: 0~8kΩ(automatically change range in 2ohm /20ohm /80ohm/800ohm/8kohm)
Error< 0.2%RDG+0.02%FS Maximum resolution: 0.1mΩ
14Temperature measurement-50~100 Celsius degree, error<3 Celsius degree
15CT Secondary burdenRange 0-160ohm (automatically change range in 2ohm/ 20ohm/80ohm/160ohm)
Error <0.2%RDG+0.02%FS Maximum resolution 0.001ohm
16PT Secondary burdenRange 0-80kohm (automatically change range in 800ohm / 8kohm /80kohm)
Error <0.2%RDG+0.02%FS Maximum resolution: 0.1ohm
17PT ratio measurementRange: 1~30000, 1~5000 error<0.2% 5000~30000 error<0.5%
18Saved data groups>1000groups
19Work conditionTemperature:-10ºC-50ºC, moist:≤90%
20Size49*19*36CM
21Weight15kg