Features: .1 set of SF1000 host machine can manage 5 set of auxiliary machines, the unit devices are managed by registration mechanism, and can be managed by the same motherboard with any combination of 1 to 6 devices
.Safety operation
The battery access is connected with a double circuit breaker and equipped with a air switch. The battery can be completely disconnected in case of over current, short circuit, over temperature, etc.. RF wireless communication or 485 wire communication between the host and auxiliary machine.
. Maximum 64 work steps can be set, the charging and discharging processes with 64 working steps or less can be flexibly set, and the working steps such as Idling, pause and cycle can be set to meet the needs of different working steps
. Cycle number can be set to 9999 times at max.
. Remote operation by network, Installing the dedicated software of this device, which may remotely operate the devices through network: data setting, data collection, data checking and so on.
. 7" color sensitive touch panel of the host machine, the date setting and operation can be processed via the touch panel.
. All English menu operation, clear interface, the screen can display each step of the operation tips, convenient for users to use.
. You can view all charging and discharging parameters on the screen in the process of charging and discharging , and it can display the curve of battery charging and discharging voltage in real time
. Independent channel status indicator light, you can check the running state of the machine at any time
Technical Specification Model No.: | SF1000 |
Supply voltage: | AC 220V±10% |
Host availably increased capacity | 5 sets of auxiliaries |
Communication among the host and auxiliaries | RF wireless or 485 wire communication |
Menu Language: | English |
Operation Methods: | 7" touch panel and Remote operation |
Current Accuracy: | 0.1A |
Voltage Accuracy: | 0.01V |
Discharge Current | 1-30A (2V) 1-100A (6V/8V/12V) Constant current adjustable |
Charge and Discharge Voltage: | 1.7V-2.4V(2V) 5.1V-15V(6V/8V/12V) Constant voltage adjustable |
Charge Current | 0-30A constant current adjustable |
Cycle Number: | 1-9999times |
Comm. Port: | LAN |
Detection Cables: | 3 m, 35 mm2 copper cables |