240W 48V 5A AC to DC DIN Rail Power Supply

Min.Order: 10
Product origin: Wenzhou, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 40.17 ~ 42.23

Description
240W Single Output Industrial DIN Rail Power Supply        NDR-240 series
Features:
Universal AC input/ full range
Built-in active PFC function
Protections: Short circuit/ Over load/ Over voltage/ Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
LED indicator for power on
100% full load burn-in test
Fixed switching frequency at 100KHz
2 year warranty
SPECIFICATIONS
OUTPUT 
ModelNDR-240-24NDR-240-48
DC Voltage 24V48V
Rated Current 10A5A
Current Range 0-10A0-5A
Rated Power 240W240W
Ripple & Noise 150mVp-p150mVp-p
Voltage Adj. Range 24-28V48-55V
Voltage Tolerance ±1%±1%
Setup, Rise Time 1500ms,100ms/230VAC   3000ms,100ms/115VAC at full load
Hold Up Time 28ms/230VAC   22ms/115VAC at full load
Voltage Range 90~264VAC   47~63Hz; 127~370VDC
AC Current2.5A/115V   1.3A/230V
Efficiency84%85%
Inrush Current Cold start 20A/115V   35A/230V
Leakage Current<1mA/240VAC
Over Load 105%~130%
Protection type: Constant current limiting, recovers automatically after fault condition is removed
Over Voltage 29-33V56-65V
Protection type: Shut down o/p voltage, re-power on to recover
Over Temp.100ºC±5ºC(TSW1)
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down
Working Temp., Humidity-10ºC~+70ºC; 20%~90%RH
Storage Temp., Humidity-20ºC~+85ºC; 10%~95%RH
Vibration10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes
Withstand VoltageI/P-O/P: 3KVAC   I/P-FG: 1.5KVAC   O/P-FG: 0.5KVAC
Isolation ResistanceI/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC
Safety StandardDesign refer to UL508,UL60950-1, TUV EN60950-1
EMC StandardEN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2(EN50082-2)
Dimension125.5*125.2*100mm(L*W*H)
Weight1.3Kg
Packing12pcs/15.5Kg/1.2CUFT
NOTE 
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.
3 .Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
5 . Derating may be needed under low input voltages. Please check the derating curve for more details.
Product Description


 