PRT-PC3 Microcomputer Control Three Phase Protection Relay Test Kit is applied to test the relay unit in relay protection system. At the same time it could be considered as a universal three phase AC/DC voltage source or current source.
PRT-PC3 Microcomputer Control Three Phase Protection Relay Test Kit is applied to test protection replay based on voltage and current operation. The main function of the tester include: calibration of voltage and current operation relays, secondary circuit inspection,trip value of circuit breaker test, switch on and off time measurement of circuit breaker and so on. It's a low cost, simple operation and reliable performance device for secondary circuit test.
No. | Items | Specifications | |
Alternating Current(AC) output | |||
1 | Output accuracy | 0.5magnitude | |
2 | Phase current output (effective value) | 0~30A | |
3 | Three parallel phase current output (effective value) | 0~90A | |
4 | Phase current value with long time under permission (effective value) | 10A | |
5 | Phase current maximum power output | 420VA | |
6 | Three parallel phase current maximum power output | 900VA | |
7 | Three parallel phase current maximum work time | 10s | |
8 | Frequency range (base wave) | 20~1000Hz | |
9 | Harmonic frequency number | 1~20 time | |
Direct Current(DC) output | |||
1 | Output accuracy | 0.5magnitude | |
2 | Current output | 0 ~ ± 10 A/each phase 0 ~ ± 30 A/every three parallel | |
3 | Maximum output of load voltage | 20v | |
Alternating Voltage output | |||
1 | Output accuracy | 0.5magnitude | |
2 | Phase voltage output (RMS) | 0 ~ 120v | |
3 | Line voltage output (RMS) | 0 ~ 240v | |
4 | Phase voltage/line voltage power output | 80VA/100VA | |
5 | Frequency range (base wave) | 20 ~ 1000Hz | |
6 | Harmonic frequency number | 1 ~ 20 times | |
Direct voltage output | |||
1 | Output accuracy | 0.5magnitude | |
2 | Phase voltage output amplitude | 0 ~ +160v | |
3 | Line voltage output amplitude | 0 ~ + 320v | |
4 | Phase voltage/line voltage power output | 70VA/140VA | |
1 | AC current and voltage error | <0.5%RDG+0.05%FS | |
2 | DC current error | <0.5%RDG+0.05%FS | |
3 | DC voltage error | 1%RDG+0.1%FS | |
4 | Binary input | Active node 0~250V, 0~6V for "0", 6~250V for "1", passive node: 20mA max | |
5 | Binary output | DC 220V/0.2A, AC 220V/0.5A | |
The switch quantity and time measurement | |||
1 | Switch parameters input | 7 ways; Empty contact: 1~20mA, 24v; Power contact access: "0": 0-+6V; "1":+11 V-+250V; | |
2 | Switch parameters output | 2 couples DC: 220V/0.2A; AC: 220V/0.5A | |
3 | Time measurement | Measuring range: 0.1ms - 9999s / 0.1ms | |
1 | Power supply | AC220V ± 10%, 50Hz/60Hz | |
2 | Environment temperature | 0~50°C | |
3 | Humidity | ≤85%RH | |
4 | Weight | <18KG |