Manufacturer Supply Portable 10 Inch Ultra-Thin Heart Rate Multi Parameter Patient Monitor for Dental

Min.Order: 1
Product origin: Suzhou, Jiangsu, China
Infringement complaint: complaintComplaint
US$ 350 ~ 500

Description
China Manufacturer Portable 10 Inch Ultra-thin Bedside Multi parameter Patient Monitor for Dental

Technical Parameter:

ECG
* Lead selection: full lead, I,II III, aVF, aVR, aVL, V1-6 chest lead display
* Gain selection: ×1, ×2, ×0.25, ×0.5 four gears
* Frequency: 0.5Hz-100Hz
* Common mode signal rejection: greater than 70dB
* Scanning speed: 12.5mm/s, 25mm/s, 50mm/s three standard files
* Heart rate accuracy: ±5 beats/minute
* Calibration signal: 1mV (peak value, accuracy ±3%)
* ST segment detection: measuring range (-2.0mV---+2.0mV)
* Use standard: in line with ANSI/AMI EC13-2002 standard
* Response time: 1s
* Alarm mode: sound and light alarm
* Heart rate alarm preset range: (exceed the preset value alarm)
The upper limit is adjustable between 1-255 times/minute
The lower limit is adjustable between 0-254 times/minute


NIBP Blood Pressure
* Technology: oscillometric method
* Measurement method: reverse measurement data is more accurate
* Unit of measurement: mmHg/Kpa
* Overvoltage protection: double safety protection
* One measurement time: less than 45s
* Pressure range in cuff: 0-250mmHg
* Blood pressure measurement accuracy: ANSI/AAMI SP10-2002 standard stipulates the average error and standard deviation value
* Initial inflation of the cuff: 180mmHg (120mmHg for children)
* Cuff subsequent inflation: original systolic blood pressure +30mmHg
* Blood pressure measurement range and error:
Systolic blood pressure 60 mmHg~250 mmHg
Average pressure 45 mmHg~235 mmHg
Diastolic blood pressure 40 mmHg~220 mmHg
* Blood pressure measurement error: ±1.1KPa (±8mmHg) or ±10%, whichever is greater
* Response time: 1s
* Alarm mode: sound and light alarm
* Alarm prediction range and error: (Alarm when exceeding the preset value)
* Systolic blood pressure upper limit 1mmHg~255 mmHg
                     Lower limit 0 mmHg~254 mmHg
* Diastolic blood pressure upper limit 1mmHg~255 mmHg
       Lower limit 0 mmHg~254 mmHg
* Alarm error: ±1 mmHg
* Use standard: in line with ANSI/AAMI SP10-2002 standard

SPO2 Blood Oxygen Saturation
* Range: 0-100%
* Accuracy: 1%
* Resolution: 1%
* Pulse frequency: 20-250 beats/min
* Response time: 1s
* Alarm mode: sound and light alarm
* Alarm range and error: (Alarm when exceeding the preset value)
Upper limit 1%~100%
Lower limit 0%~99%

TEMP Body Temperature
* Technology: Highly sensitive thermistor probe
* Body temperature measurement range: 20°C -- 45°C
* Resolution: 0.1%
* Body temperature accuracy: ±1°C
* Response time: 1s
* Alarm mode: sound and light alarm
* Alarm preset range and error: (Alarm when exceeding the preset value)
The upper limit is adjustable between 20.1°C -- 45.5°C
The lower limit is adjustable between 20°C and 45.4°C
* Alarm error: ±1°C

RESP Breath
* Respiratory frequency range: 0-60 times/minute
* Accuracy: ±1rpm
* Response time: 1S
* Gain selection: ×1, ×2, ×4, ×0.5 four gears
* Alarm mode: sound and light alarm
* Alarm preset range and error: (Alarm when exceeding the preset value)
The upper limit is adjustable between 10-100 times/minute
The upper limit is adjustable between 0-99 times/minute
* Alarm error: ±1rpm

System
* Display: 10.1-inch TFT true color LCD display
* Battery (lithium battery): fully sealed maintenance-free battery
* Safety standard: IEC601-1 (International GB9706.1)
Product Tag:
Related categories:
Scroll to Top