<1>. Working Principle: Open loop direct measurement
<2>. Usage: Used for measuring DC, AC, pulse current and other arbitrary waveform current.
<3>. Advantages: Better cost performance, low power consumption, small volume, light weight, easy installation, perforation input and no insertion loss.
<4>. Application: Frequency conversion speed control system, electric welding machine, electrochemistry, power supply monitoring, electric locomotive, low level starting protection.
<5>. The input, output, power and outer shell are isolated, with strong anti-interference ability and high reliability.
<6>. Full channel configuration, parameter customizable.
Input signal | 0-5A.0-10A.0-50A.0-100A |
Active current | 0 (1) mA ~ 20mA; 0mA ~ 10mA |
Output signal | 4-20mA, 20-4mA.0-10V,Switch quantity, etc. |
Wiring method | 8 mm, 12 mm perforation |
Power supply | DC24V, DC12V, AC220V |
Accuracy | 0.20% |
Linearity | 0.10% |
Insulation voltage | 3KV / 50HZ, 1 minute |
Output temperature drift | 100ppm / °C |
Full load power consumption | 1W |
Load capacity | ≤500Ω |
Response time | ≤50MS |
Working temperature | -20 ° C ~ 60 ° C |
Dimensions | 24 * 99 * 65 mm |