Vortex flow meters are designed for measuring the volume/mass flow of liquids, gases and steam based on Karman vortex principle.


Adopting advanced differential algorithm along with measurement of isolation, shielding and wave filtering, F58 series vortex flow meters have the advantages of immunity on vibration and noise. Meanwhile, the liabilities of F58 series vortex flow meters are well guaranteed by unique sensor packaging technology.


Upon receipt, examine your meter for visible damage. The Vortex is a precision measuring instrument and should be handled carefully. Remove the protective plugs and caps for a thorough inspection. If any items are damaged or missing, contact us.


Make sure the Vortex flow model meets your specific needs. For your future reference, it might be useful to record this information on nameplate in the manual in case it becomes unreadable on the Vortex. Refer to the nameplate for your customized product's specification.
 

Detailed Photos

Product Parameters

Measuring system
 

Application range(1) Gas; (2) Liquid; (3) Steam
Measured Value
Primary measured valueFlow Rate

Secondary measured value
Volume flow ; (Pressure and Temperature is available for model with compensation)

Design
 
Features 
Modular constructionThe measurement system consists of a flow sensor and a signal converter. It is available as
compact and as separate version.
Compact version converterN Type: Pulse output without local display
A Type: 4-20mA Output without local display
B Type: Local Display; Lithium Battery Power; No Output  
(Battery Part No.:ER26500)
C Type: Local Display; 24V DC Power; 4-20mA Output;
Optional Function:
(1) Backup Power Supply: Lithium Battery
(2) Modbus RS485
(3) Pulse Output
ConnectionFlange: DN15-DN300
Wafer: DN15-DN300
Measurement RatioStandard - 10:1

Measuring accuracy
 
Reference conditionsFlow conditions similar to EN 29104
Medium: Water / Gas
Electrical conductivity: ≥ 300 μS/cm
Temperature: +10...+30°C / +50...+86°F
Inlet section: ≥ 10 DN
Operating pressure: 1 bar / 14.5 psig
Flow Meter AccuracyFor Liquid: 1.0% of rate
For Gas and Steam: 1.5% of rate