Kfz Transformer with Load Loss and Empty Load Loss Tester

Min.Order: 1
Product origin: Chongqing, China
Infringement complaint: complaintComplaint
US$ 2000 ~ 3000

Description
 KFZ Transformer With Load Loss and No Load Loss Tester
Product Description
KFZ Transformer With Load Loss and No Load Loss Tester is designed for transformer capacity, load loss and no load loss testing.

KFZ Transformer With Load Loss and No Load Loss Tester can measure following parameters of transformer: capacity, transformer type, no-load current, no-load loss, short circuit (load) loss and impedance voltage.

KFZ Transformer With Load Loss and No Load Loss Tester is reliable, accurate, simple for wiring and operation.

 

Product Parameters
No.Item NameKFZ Transformer With Load Loss and No Load Loss Tester
1Test ParametersTransformer capacity, no-load current, no-load loss, short circuit voltage, short circuit (load) loss
2Working powerInput voltage185Vac~250Vac
Allowable input voltage85Vac~264Vac
Frequency50/60Hz
Allowable frequency45Hz~65Hz
Input power40VA
3AC voltageRange10~650V
Resolution0.001V
Accuracy0.2%±0.001V
4AC CurrentRange0.5~60A
Resolution0.001A
Accuracy0.2%±0.001A
5FrequencyRange45Hz~65Hz
Resolution0.001Hz
Accuracy0.2%±0.001Hz
6PowerRange0~39kW
Resolution0.001kW
Accuracy<±0.5%(CosΦ>0.1)
±1.0%(0.02<CosΦ<0.1)
7Capacity test range10kV Dry type transformer30kVA~3150kVA
10kV Oil immersed transformer30kVA~3150kVA
35kV Oil immersed transformer50kVA~31500kVA
20kV Dry type transformer50kVA~2500kVA
35kV Dry type transformer50kVA~2000kVA
8EnvironmentOperating temperature-10ºC~+50ºC
Storage temperature-25ºC~+70ºC
Relative humidity5%~95%
9Dimension40cm*30cm*22cm
10Weight≈8kg (Excluding accessories)
 
Features
Measurement range of voltage, current and capacity is wide, and measurement range can convert automatically. For example, the instrument can complete load test under full current of distribution transformer below 1000kVA. The load test of distribution transformers below 3150kV can be completed under 1/3 of the rated current (under 1/3 rated current, the instrument can be converted to the load loss parameter under the rated current).

When testing load and no load loss of three phase transformer, it can automatically determine whether the wiring is correct or not, and display vector of three phase voltage and current.

All test results can be automatically corrected. LCD 20 * 240 large screen.

Users can preset 40 sets sample parameters, and these parameters can be deleted or added at any time.

With real-time electronic clock, which can automatically record test date and time.

500 sets test data can be stored in the tester, meanwhile, users can connect the tester with computer to upload the data.

With built-in printer, users can print test result immediately after test.

Allows external current transformers or voltage transformers to extend measurement range, so it can test any kinds of transformers.
Detailed Photos

 

Packaging & Shipping
The whole set of KFZ Transformer With Load Loss and No Load Loss Tester is packed in one plywood case;

Packing dimension: 55cm * 45cm * 40cm;

Total weight: 18kg;

It is suitable for shipping by Express.