Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs

Min.Order: 1
Product origin: Wenzhou, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 220

Description
 
ProductMedium voltage SF6 load breaker switch
Rated voltage12KV, 24KV, 36KV
Rated currentup to 1250A
Breaking currentup to 31.5KA

 
Product Description

FL(R)N36-12(D) Load switches and combiners (hereinafter referred to as "load switches" and "combiners") are suitable for three-phase ac power systems of 10kV and 50Hz. This product as industrial and mining enterprises, high-rise buildings, residential quarters, pre-installed type substation, for the breaking, closing load current, the fault current, control and protection circuit and the power distribution transformer.

Normal operating conditions

a)Ambient air temperature is not more than 40 ºC, and at 24 h closed to the average no more than 35 ºC. Minimum ambient air temperature 25 ºC.
b)The effects of sunlight can be ignored
c)No more than 3000m above sea level.
d)Ambient air is not significantly contaminated by dust, smoke, corrosive and/or flammable gases, vapors, or salt fog. If the user does not have special requirements, the manufacturer may consider that these situations do not exist.e)The humidity conditions are as follows:
--The average relative humidity measured within 24h is no more than 95%.
--The mean value of water vapor pressure measured within 24h shall not exceed 2.2kPa.
--The average monthly relative humidity should not exceed 90%.
--The average monthly water vapor pressure does not exceed 1.8kpa. In such conditions appear condensation occasionally.
e) The vibration or ground motion from the outside of the switching equipment and the control equipment has no obvious relationship with the normal operation mode of the equipment. If the user has no special requirements, the manufacturer may not consider these situations.

GB 3804-2004        3.6KV~40.5KVHigh voltage ac load switch
GB 16926-2009       High voltage ac load switch fuse combination electrical appliance
GB 11023-1989       Test guide for fln36 gas seal of high pressure switching equipment
GB 1985-2004        High voltage ac isolation switch and ground switch
GB/T 11022-2011 Common technical requirements for high voltage switching equipment and control equipment standards

Item NO.NameUnitTechnical parameters
Load break switch panel
1Rated Voltage UnkV122436
2Rated FrequencyHz505050
3Rated CurrentA630630630
4Rated Load Breaking CurrentA630630630
5Rated Short Time Withstand Current(rms)kA202020
6Rated Short Time Durations333
7Rated Peak Withstand Current kA505050
8Rated Closed Switch - Off CurrentA630630630
9Rated Cable Charging Breaking CurrentA101010
10Rated Active Load Breaking CurrentA630630630
13Earthing Switch 2s Short Time Withstand Current kA202020
14Rated Short-Circuit Current Making Times times222
15Rated Current Breaking Timestimes101010
16Mechanical Endurance Load Break Switchtimes300030003000
Earthing Switchtimes200020002000
17SF6 gas anual leakage rate≤ /year0.10%0.10%0.10%
18Rated Insulation LevelUnitTechnical parameters
1min Power Frequency withstand voltage(rms)On isolating distancekV4860110
Phase to Phase kV425085
Phase to EarthkV425085
Lightning impulse withstand voltage(peak)On isolating distancekV85145215
Phase to Phase kV75125185
Phase to EarthkV75125185

 

Product Parameters

 

Detailed Photos


 

Certifications

Company Profile




Packaging & Shipping
 
 

 

Our Advantages

1. R&D Ability

We are specialized in the field for more than 10 years, and has a well experienced R&D team taking the design and development work for each project based on customer's special demands.
 
2. QC Team
We have extremely strict QC procedure from components to finished products.
 
3. Production Capacity
Steady production period within 15 days.
 
4. High Quality Product
We have full set of test reports for products and are supplying for the world's largest utility - State Grid Corporation of China(SGCC) and China Railway Construction Group.
 
FAQ

Q1: Are you factory or trading company?

A: Factory, we can guarantee our price is reasonable and competitive.
 
Q2: When can I have the price?
A: Usually we quote within 24 hours after receiving your inquiry.
 
Q3: How could I get a sample?
A: If you can not buy our product in your local area, we will ship a sample to you. You will be charged of sample price plus all related shipping costs.

Q4: Can we print our logo and company name on products?
A: Yes, of course, we accept OEM.
 
Q5: What is the lead time?
A: The lead time depends on the quantities ordered, normally within 7-20 days after receiving the payment.
 
Q6: How's your quality control process?
A: All products will be inspected starting from accessories, and will be carried out with routine tests before leaving
our factory.
 
Q7: How to solve the quality problems after sales?
A: Take photos or video of the quality problems and send to us for our checking and confirming, and we will make a satisfied solution for you within 1-3 days.
 
Q8: What's the warranty time?
A: 12 months from shipping date.

Q9: Why choose us?
A:1.We are specialized in the field for more than 10 years, and has a well experienced R&D team taking the design and development work for each project based on customer's special demands.
2.We have extremely strict QC procedure from components to finished products.
3.Steady production period within 15 days.
4.We have full set of test reports for products and are supplying for the world's largest utility - State Grid Corporation of
China(SGCC)
and China Railway Construction Group.
Product Tag:
Related categories:
Scroll to Top