Medical Device Portable Multi Parameter Patient Monitor with Optional Printer

Min.Order: 1
Product origin: Huizhou, Guangdong, China
Infringement complaint: complaintComplaint
US$ 290 ~ 335

Description
Product Description

Medical Device Portable Multi Parameter Patient Monitor with Optional Printer
Features
* 12.1 inch high brightness (800x600) colorful TFT LCD
* Simultaneous display of 7 lead ECG waveform  
* Indented menu layout to maximize the space for display        
* Protection agasint defibrillation and ESU interference 
* New SPO2 technology to assure precise measurement            
* Precise SPO2 measurement for low prefusion & finger motion                            
* Analysis of real time ST segment arrhythmia
* Able to analyze 15 kinds of drug level          
* 168 hour graphic and tabular trend with data storage
* High efficient power management without electric fan to avoid cross contamination  
* Up to 66 beds for networking capacity to connect with HIS
* 750 group NIBP data for recall and display 


Standard configuration: ECG, NIBP, SpO2, PR, RESP., TEMP., HR, 
Optional configuration: 1/2/4 IBP, EtCO2, multi gas, CO, 12 lead ECG, thermal recorder, touch screen, WiFi, HDMI, USB, VGA,        SunTech NIBP

Product Parameters

ECG

Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection: I, II, III, avR, avL, avF, V,
Waveform: 3 channel
Gain2.5 mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV, auto
HR and Alarm Range: Adult: 15 ~ 300 bpm, Neo/Ped: 15 ~ 350 bpm
Accuracy: ± 1% or ± 1 bpm, whichever greater
Resolution: 1 bpm
Sensitivity:  > 200 (uVp-p)
Differential Input Impedance:  > 5 MΩ
CMRR: Monitor: > 105 dB, Operation: > 105 dB, Diagnosis: > 85 dB
Electrode offset Potential: ± 300 mV
Leakage Current: < 10 uA
Baseline Recovery:  < 3 seconds after defibrillation
ECG Signal Range: ±8 mV (Vp-p)
Bandwidth:Surgery: 1 ~ 15 Hz, Monitor: 0.5 ~ 35 Hz, Diagnostic: 0.05 ~ 100 Hz
Calibration Signal:  1 (mVp-p), accuracy: ±5%
ST Segment Monitoring Range: Measure and Alarm: -2.0 ~ +2.0 mV
Alarm:  Available 
Review:  Available

SpO2

Measurement Range:  0 ~ 100 %
Alarm Range: 0 ~ 100 %
Resolution: 1 %
Accuracy: 70% ~ 100%: ±2 %, 0% ~ 69%: unspecified
Actualization interval: about 1 second
 Alarm Delay:  10 second
 Pulse Rate Measurement and Alarm Range: 0 ~ 254 bpm
Resolution: 1 bpm
Accuracy: ± 2 bpm

NIBP

Method: Oscillometric
Mode: Manual, Auto, STAT
Measurement Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (minutes)
Measurement Period in STAT Mode: 5 minutes
Pulse Rate Range: 40 ~ 240 bpm
Alarm Type:  SYS, DIA, MEAN
Measurement and Alarm Range
Adult Mode: SYS: 40 ~ 270 mmHg, DIA: 10 ~ 215 mmHg, MEAN: 20 ~ 235 mmHg
Pediatric Mode: SYS: 40 ~ 200 mmHg, DIA: 10 ~ 150 mmHg, MEAN: 20 ~ 165 mmHg
Neonatal Mode:  SYS: 40 ~ 135 mHg, DIA: 10 ~ 100 mmHg, MEAN: 20 ~ 110 mmHg
Resolution: Pressure: 1mmHg
Accuracy: Pressure
                  Maximum Mean error: ±5 mmHg
                  Maximum Standard deviation: ±8 mmHg
Overpressure Protection
    Adult Mode: 297 ± 3 mmHg
   Pediatric Mode: 240 ± 3 mmHg
   Neonatal Mode: 147 ± 3 mmH

Respiration

Method:  Impedance between R-F (RA-LL)
Differential Input Impedance:  >2.5 MΩ
Measurement Impedance Range:  0.3~5.0 Ω
Baseline Impedance Range: 0 - 2.5 KΩ
Bandwidth:  0.3 ~ 2.5 Hz
Resp. Rate
Measurement and Alarm Range: Adult: 0 ~ 120 rpm, Neo/Ped: 0 ~ 150 rpm
Resolution: 1 rpm
Accuracy: ±2 rpm
Apean Alarm: 10 ~ 40 S

Temperature

Channel: 1
Measuring and Alarm Range: 0 ~ 50 °C
Resolution: 0.1 °C
Accuracy: ± 0.1 °C
Actualization interval:  about 1 second
Average Time Constant: < 10 second

 

Packaging & Shipping

Product dimension & weight
Length×Width×Height: 312mm×287mm×175mm
Weight: 3.4 Kg


Package list:
1* PM-200A Patient Monitor
1* ECG Cable(5 Lead)
1* ECG Electrodes
1* SpO2 Probe
1* NIBP Cuff
1*
Temp Probe
1* Extension tube
1* Power Wire
1* Grounding cable 
1* User manual 
1* Warranty
1* Certificate of Qualification

Packing: 1pc/carton, size: 39*37*30cm