Model | SS7122 | SS7120 | SS7112 | SS7110 | |||
AC WITHSTAND VOLTAGE | |||||||
Output Rating | 5KVAC/12mA | ||||||
Output Voltage, KVAC | Range | Resolution | Accuracy | ||||
0-5.00 | 0.01 | ± (2% of setting + 5V) | |||||
Output Frequency | 50Hz/60Hz ± 100ppm, User Selection | ||||||
Output Waveform | Sine Wave, THD. < 2% (Resistive Load), Crest Factor = 1.3 - 1.5 | ||||||
Output Regulation | ± (1% of output + 5V), From no load to full load | ||||||
SETTINGS | |||||||
Hi-Limit AC Current, mA | 0.10 - 12.00 | 0.01 | ± (2% of setting + 2counts) | ||||
Lo-Limit AC Current, mA | 0.00 - 12.00 | 0.01 | ± (2% of setting + 2counts) | ||||
Ramp Time, second | 0.1 - 999.9 | 0.1 | ± (0.1% + 0.05sec) | ||||
Dwell Time, second | 0, 0.2 - 999.9 ( 0=continuous) | 0.1 | |||||
Arc Detection | 0, 1 - 9 ranges (0=OFF, 9 is the most sensitivity) | ||||||
DC WITHSTAND VOLTAGE (7120, 7122 ONLY) | |||||||
Output Rating | 6KVDC/5mA | ||||||
Output Voltage, KVDC | 0 - 6.00 | 0.01 | ± (2% of setting + 5V) | ||||
Output Ripple | < 5%(6KV/5mA at Resistive Load) | ||||||
SETTINGS | |||||||
Hi-LimitDCCurrent, mA | 0.02 - 5.00 | 0.01 | ± (2% of setting + 2counts) | ||||
Lo-LimitDCCurrent, mA | 0.00 - 5.00 | 0.01 | ± (2% of setting + 2counts) | ||||
Ramp Time, second | 0.1 - 999.9 | 0.1 | ± (0.1% + 0.05sec) | ||||
Dwell Time, second | 0, 0.2 - 999.9 (0=continuous) | 0.1 | |||||
Arc Detection | 0, 1 - 9 ranges (0=OFF, 9 is the most sensitivity) | ||||||
Discharge Time | < 200 msec | ||||||
INSULATION RESISTANCE (7112, 7122 ONLY) | |||||||
Output Rating | 1KVDC/1000MΩ | ||||||
Output Voltage, KVDC | 0.10 - 1.00 | 0.01 | ± (2% of setting + 2V) | ||||
SETTINGS | |||||||
Hi-Limit Resistance, MΩ | 0, 1 - 1000 (0=OFF) | 1 | ± (3% of setting+2counts)at > 500VDC ± (7% of setting +2counts)at < 500VDC | ||||
Lo-Limit Resistance, MΩ | 1 - 1000 | 1 | |||||
Delay Time, second | 0, 0.5 - 999.9 (0=continuous) | 0.1 | ± (0.1% + 0.05sec) | ||||
MEASUREMENT | |||||||
AC/DC Voltage, KV | 0 - 6.00 | 0.01 | ± (2% of reading + 1count) | ||||
DC Voltage, KV (IR only) | 0.10 - 1.00 | 0.01 | ± (2% of reading + 2V) | ||||
AC Current, mA | 0.10 - 12.00 | 0.01 | ± (2% of reading + 2counts) | ||||
DC Current, mA | 0.02 - 5.00 | 0.01 | ± (2% of reading + 2counts) | ||||
Resistance, MΩ | 1 - 1000 (Auto Range) | 0.001 0.01 0.1 | ± (3% of reading+2counts)at > 500VDC ± (7% of reading +2counts)at < 500VDC | ||||
GENERAL | |||||||
Input Voltage AC | 110/220Vac± 15%, 50/60Hz ± 5%, Fuse 3A Fast | ||||||
PLC Remote Control | Input: Test, Reset | ||||||
Output: Pass, Fail, Processing | |||||||
Memory | 5 Sets Store/Recall of each Memory, 4 Test Mode Selectable (W, I, W I, I W Only 7112, 7122) | ||||||
Display | 16× 2 LCD with back light | ||||||
Key Lock | To prevent unauthorized alteration of the test Parameters | ||||||
Calibration | Build-in software and external calibrated meters | ||||||
Environment | 0-40º C, 20-80%RH | ||||||
Dimension/Net Weight | 280mm(W)× 89mm(H)× 370mm(D)/ 9Kg | ||||||
STANDARD ACCESSORIES | |||||||
Power Cord(10A) | × 1 | ||||||
Fuses | × 3 (Including a spare contained in the fuse holder) | ||||||
High Voltage Test Cable(1101) | × 1 | ||||||
Return Test Cable(1102) | × 1 |