Gfuve 220V 120A 1 Phase Energy Meter Calibration Test Bench

Min.Order: 1
Product origin: Beijing, China
Infringement complaint: complaintComplaint
US$ 15000

Description
GF102 GFUVE 220V 120A 0.05% Single Phase Energy Meter Calibration Test Bench
GF102 portable single phase energy meter testing bench used to test single phase energy meter. Adopt mature signal synthetic and power amplifier technology, high precision voltage and current output. Widely used in lab and field, and then as single phase standard source.

Features
Meter under testing: 1P2W
2Testing mode: active power, reactive power
Test 3pcs or 2pcs meter synchronously
Start testing and creep testing
Reference standard and power source integrated, easy to carry
Measuring mechanical meter and electric meter
Operating by manual keyboard or PC software
With keyboard shortcuts
Internal large capacity storage device for mass memory
Local checking the testing result
Overload, short circuit, open circuit protection
With self-checking function
Parameters
Electrical parameters
Accuracy class 0.05%, 0.1%
Power supplyOne Phase AC 100-265V, frequency 50/60Hz.
AC Voltage Output
Range57.7V, 100V, 220V, 380V; max 500V
Adjustment range(0-120)%RG(1)
Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability0.01%/120s
Distortion0.1% (Non-capacitive load)
Output loadmax 25VA
Measuring accuracy0.05%RG
AC Current Output
Range200mA, 1A, 5A, 20A, 100A; max 120A
Adjustment range(0-120)%RG
Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability<0.01%/120s
Distortion≤0.1% (Non-capacitive load)
Output loadmax 50VA
Accuracy0.05%RG
Power Output
Active power output stability<0.01%RG/120s
Reactive power output stability<0.02%RG/120s
Active power measuring accuracy0.05%RG
Reactive power measuring accuracy0.1%RG
Phase Output
Output adjustment range0°-359.999°
Output adjustment fineness10, 1, 0.1, 0.01 as optional.
Resolution0.01°
Accuracy0.05°
Power Factor
Adjustment range-1 ~ 0 ~ 1
Resolution0.0001
Measurement accuracy0. 0005
Frequency Output
Adjustment range40Hz-70Hz
Output adjustment fineness5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
Resolution0.001Hz
Accuracy0.005Hz
Voltage /Current/Harmonic Setting
Harmonic number2-51times
Harmonic content0-40%
Harmonic phase0-359.99
Harmonic setting accuracy(10%±0.1%)RD(2)
Power Energy Measurement Error
Active power energy0.05%RG
Reactive power energy0.1%RG
Power Pulse Output
Power pulse typeactive pulse, reactive pulse
Active power pulse output5V,10mA
Power Pulse Input
Energy pulse typesupport active and reactive pulse, the highest frequency
power pulse input is 180K.
Mechanical parameters
Dimensions (W×D×H) (mm)455x440x150
Weight (kg)12
Environmental conditions
Ambient temperature-10°C to +40°C
Relative humidity35%-85%
(1)RG means range, the same as below;
(2)RD means the setted harmonic content, harmonic can be a single output,also multiple output.