needle burner | the hole Φ 0.5mm ± 0.1mm, outside diameter ≤ Φ 0.9mm, length ≥ 35mm, |
Material | stainless steel |
burner angle | tilt 45 ° (test) or vertical (adjust the flame height) |
Application time | 0-999 .9 s ± 0.1s adjustable (normally choose to 30s) |
Burning duration | 0-999 .9 s ± 0.1s, auto record, manual suspension |
flame height | 12mm ± 1mm (with a height measurement apparatus) |
Burn gas | 95% of the butane gas (Pressure:Less than 0.2MP) |
temperature measurement range | 0 ~ 1000 ºC |
flame temperature requirements | from 100 ºC ± 2 ºC 700 ºC ± 3 ºC rise to the time in 23.5 seconds ± 1 seconds |
Thermocouple | Φ0.5mm (K type) |
experimental background | black background |
test procedure | automatic control |
reference standard | IEC60695 -11-5-2004, GB/T5169.5-2008 |
inside dimension | 0.5 cubic meters, stainless steel chassis |
equipment dimensions | 1000mm wide × 650mm deep × 1300mm high |
power supply | AC220V ± 5%, 50Hz, 0.3KVA |