Gfuve GF438II Handheld Three Phase Power Quality and Energy Analyzer

Min.Order: 1
Product origin: Beijing, China
Infringement complaint: complaintComplaint
US$ 9898

Description
GFUVE GF438II Handheld three phase power quality and energy analyzer


GF438II handheld three phase power quality analyzer with CT offer the best ability in power quality analysis, GF438II handheld power quality analyzer help locate, predict, prevent and troubleshoot power quality problems in three phase and single phase power distribution systems. Additionally, GFUVE patented energy loss algorithm, unified power measurement, measuring and counting energy losses due to harmonics and unbalance issues, allowing the user to pinpoint the origin of energy losses in the system.



Features
3s statistical interval, continuously record 720h;
Support multi-brand current transformer;
Up to 32G data storage space;
Record up to 461 power energy parameters simultaneously;
Up to 6500 screenshots saved;
Support periodic recording function;
Up to 3.9M/s USB high-speed transfer;
Customized international report generation.

Functions
Energy loss calculator: classic active and reactive power measurements, unbalance and harmonic power, are quantified to pinpoint true system energy losses in dollars (other local currencies available).
Power inverter efficiency: simultaneously measure AC output power for power electronics systems.
Power wave data capture: GF438II analyzers capture fast RMS data, show half-cycle and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.).
Waveform capture: GF438II capture 50/60 cycles (50/60Hz) of each event that is detected in all modes, without set-up.
Automatic transient E6000 analyzers capture 200 kHz waveform data on all phases simultaneously up to 1000V.
Fully class-A compliant: E6000 analyzers conduct tests according to the stringent international IEC 61000-4-30 class-A standard.
Mains signaling: GF438II analyzer measure interference from ripple control signals at specific frequencies.
Troubleshoot: analyze the trends using the cursors and zoom tools.
Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance.
Measure all three phases and neutral: with included four flexible current probes with enhanced thin flex designed to fit into the tightest places.
Automatic trending: every measurement is always automatically recorded, without any set-up.
System-monitor: ten power quality parameters on one screen according to EN50160 power quality standard.
Logger function: configure for any test condition with memory for up to 600 parameters at user defined intervals.
View graphs and generate reports: with included analysis software.
Battery life: up to 5 hours operating time per charge on Li-ion battery pack.

Parameters
Electrical parameters
Voltagerms, ava, pk+, pk-, rms-1/2, CF
FrequencyFreq
Currentrms, ava, pk+, pk-, rms-1/2, CF
Power & energyP, S, Q, PF, DPF, W
ComputationTHD, DC, 1-50 Harm, 1-50 InHarm, 1-35 HiHarm, 1-50 SubHarm
Voltage harmonicTHD, DC, 1-50 Harm, 0-49 InHarm, 1-35 HiHarm, 1-50 SubHarm , KF
Current harmonicTHD, DC, 1-50 Harm
Harmonic powerIa, Ib, Ic, ΣPtotal, ΣQtotal, ΣStotal, 15 minutes
Fluctuation and flickeringPST, PLT, Fluct, Fluct Max
UnbalV Pos, A pos , V neg , A neg , V zero, A zero, Unbal
Event logVoltage swell, voltage sags, DIP, surge current, voltage and current distortion out of limit, odd harmonics containing rate out of limited, unbalanced voltage current out of limit, frequency out of limit, PST out of limit, PLT out of limit, long-term voltage interruption, voltage fluctuation deviation
P, Q, S name
Measurement typesP: Calculate by every 10 cycles
S: Calculated by the effective value of voltage and current
Q: Calculated by the apparent power, active power
DisplayTable charts, trend chart
Measuring range/resolutionAccording to the range of the voltage and current
measuring accuracy±0.5% 
Arms
Measurement modeCalculated by the square root value of 10 cycle
Display modeEffective current value of each channel
Measuring range/resolutionCurrent: according to the current clamps
Option:5A/50A/100A/500A
Current clamps: 1200A/3000A/6000A(Flexible Current Clamp)
Accuracy0.1% + accuracy of the current clamps
Frequency
Measurement modeCalculate by 10 cycles (50Hz) or (60Hz)
Display modeMeasurement by 10 cycles
Nominal frequency/resolution50.000Hz/0.001Hz or 60.000Hz/0.001Hz
Bandwidth measurement42.5-57.5Hz or 52.5-67.5Hz
Measurement accuracy±0.001Hz
Half-wave RMS current/voltage
Measurement modeCalculate by every 2 cycles. Each cycle ,1/2 cycle made up of a waveform calculation
Measuring range/resolutionVoltage: 120V/0.01V, 230V/0.01V, 400V/0.01V, 1000V/0.01V,Current: According to the current clamps
measurement accuracy±0.1%
Vrms
Measuring circuit1P2W/ 2P3W /3P3W/ 3P4W
Basic frequency of the measuring circuit50Hz
Input channels4 phase voltage, 4 phase current
Measurement rangeVoltage measurement range: standard: 120V, 230V, 400V, 1000V, Max 1000V instantaneous voltage
Current measurement range: according to the current clamps, only support the v signal output current clamp
Power factor
Measurement modeThe ratio of average power to apparent power
Display modeReal-time data showed
Measurement range/resolution-1.000-1.000/0.001
Measurement accuracy±1% 
Vfund, Afund, Harmonic power
Measurement modeMeet IEC61000-4-7,Analysis time window is ten cycles
Window points5120 points
Display modeForm figure, trend charts, histograms
Number of measurement1-50 Times
Measurement accuracyVfund >1%: Error<1%
Vfund <1%: Error<0.05% Rated Voltage
Afund >3%: Error<1%
Afund <3%: Error<0.05% Current range
InHarm Voltage, InHarm current
Measurement modeMeet IEC61000-4-7, Analysis time window is ten cycles
Window points5120 points
Display modeForm figure, trend charts, histograms
Numbers of measurement1-16 groups
Measurement accuracyVfund >1%: Error<1%
Vfund <1%: Error<0.05% Rated Voltage
Afund >3%: Error<1%
Afund <3%: Error<0.05% Current range
HiHarm Voltage, HiHarm current
Measurement modeMeet IEC61000-4-7, Analysis time window is ten cycles
Window points5120 points every 10 cycles
Display modeForm figure, trend charts, histograms
Numbers of measurement1-35 groups
Measurement accuracyVfund >1%: Error<1%
Vfund <1%: Error<0.05% rated voltage
Afund >3%: Error<1%
Afund <3%: Error<0.05% current range
Voltage SubHarm Current SubHarm
Measurement modeMeet IEC61000-4-7, analysis time window is ten cycles
Window points5120 points every 10 cycles
Display modeForm figure, trend charts, histograms
Numbers of measurement1-50 groups
Measurement accuracyVfund >1%: Error<1%
Vfund <1%: Error<0.05% Rated Voltage
Afund >3%: Error<1%
Afund <3%: Error<0.05% Current range
Voltage/current Unbal (pos, neg)
Measurement mode3P3W or 3P4W, using three phase of fundamental wave components to calculate
Display modeForm figure, trend charts, histograms
Measurement accuracyVoltage unbal: ±0.2%
Current unbal: ±0.5%
Voltage fluctuation
Measurement modeCalculate by the quadratic mean of half wave.
Display modeForm figure, trend charts
Measurement accuracy±1%
IEC Flickering
MeasurementP short term (Pst) , P long term (Plt) 
Measurement modeAccording to IEC61000-4-15 Standard to calculate Pst (10 mins) Plt (2 hours) 
Display modeForm figure, trend charts
Measurement range0-20
Measurement accuracy±5%
Surge current
Measurement modeHalf-wave RMS of current is higher than set value and sustain time is 10ms-1min
Display modeMaximum of the surge current and surge current wave
Measurement accuracy0.10%
Voltage swell, Voltage sags, DIP
Measurement modeSwell: When half-wave RMS of voltage is higher than set value and sustain time is 10ms-1min, judged as swell.
Sags: When half-wave RMS of voltage is lower than set value and sustain time is 10ms-1min, judged as sags.
DIP: half-wave RMS of voltage is higher than set value and sustain time is 10ms-1min, judged as DIP
Display modeSwell, sags, DIP wave sustain time, extent and so on.
Measurement accuracy0.10%
Machinery
Size263mm x 168mm x 65mm
Weight2KG
Power supply
Voltage input110V-240V 
Adapter output15V, 3A
BatteryRechargeable nickel metal hydride, 4500mAh
Battery working time4h
Battery recharging time5h (Environment temperature 25°C)
Power saving facilityLCD backlight brightness is adjustable, standby time is adjustable
Display
Size112.8 x 84.6mm
Color260000 color
Resolutions640 x 480
BrightnessMax 350 cd/m2 (Typ), brightness is adjustable
Contrast500:1 (Typ) 
Visual angle70/70/50/70 (Typ.)(CR ≥10) ( Left/ Right/ UP/Down)
Store
TypeTF card (inbuilt) 
Size8G
Standards
Measurement methodIEC 61000-4-30
Measurement performanceIEC 61000-4-30 A LVL
FlickeringIEC 61000-4-15
HarmonicIEC 61000-4-7
Safety
Standard GB 4793.1-2007/IEC 61010-1:2001: "Measurement, control and laboratory electrical equipment safety requirements", first part: general requirements.
Security level: CAT III 1000 V/ CAT IV 600 V.
MAX voltage of phase angle inputCAT III 1000V/CAT IV 600V
Environmental conditions
Working environment0°C to +45°C, humidity below 90rh% 
Storing environment-20°C to +50°C, humidity below 95rh% (non-condensing)

Photo
 

http://guangfuhui.en.made-in-china.com
Product Tag:
Related categories:
Scroll to Top