Technical Parameter | Value | |
Input | Rated Value | Voltage: AC 100V, 220V, 380V; Current: AC 1A/5A |
Overload | Voltage: 1.2 Times Rated Value (Continuous); 2 Times Rated Value (1 Second) Current: 1.2 Times Rated Value (Continuous); 10 Times Rated Value (1 Second) | |
Frequency | 45Hz-65Hz | |
Power Comsumption | <0.5VA | |
Accuracy | Class 0.5 | |
Function | Display | LED/LCD |
Communication | RS485 (Modbus-RTU) | |
Alarm | 1 Channel Passive Reply; Contact Capacity 3A/30VDC, 3A/250VAC | |
Analog Output | DC 4-20mA (Load < 500Ω) | |
Switching | Input: 4 Channels/2 Channels Passive Contact Input | |
Output: 2 Channels Switching Output; No Relay Contact; Capacity 3A/30VDC, 3A/250VAC | ||
Auxiliary Power Supply | Voltage Range | AC/DC 85-265V |
Power Consumption | <5VA | |
Insulation Resistance | ≥100MΩ | |
Environment | Temperature | Operating: -10ºC-+55ºC Storage: -25ºC-+70ºC |
Humidity | ≤93% (No Condensation) | |
Altitude | ≤2500m |
Type | Function | Option | Option Group |
AMC96-AI | Single Phase Ammeter Display: LED Input: AC 1A/5A | /C: RS485 (Modbus-RTU) | 1. KC 2. CJM |
/M: 1 Analog Output (Programmable 4-20mA) | |||
/K: 2DI/2DO | |||
/J: Alarm | |||
AMC96L-AI | Single Phase Ammeter Display: LCD Input: AC 1A/5A | /C: RS485 (Modbus-RTU) | 1. KC 2. CJM |
/M: 1 Analog Output (Programmable 4-20mA) | |||
/K: 2DI/2DO | |||
/J: Alarm | |||
AMC96-AI3 | Single Phase Ammeter Display: LED Input: AC 1A/5A | /C: RS485 (Modbus-RTU) | 1. KC 2. CJM 3. 3M+C |
/M: 1 Analog Output (Programmable 4-20mA) | |||
/K: 2DI/2DO | |||
/J: Alarm | |||
AMC96L-AI3 | Single Phase Ammeter Display: LCD Input: AC 1A/5A | /C: RS485 (Modbus-RTU) | 1. KC 2. CJM 3. 3M+C |
/M: 1 Analog Output (Programmable 4-20mA) | |||
/K: 2DI/2DO | |||
/J: Alarm | |||
AMC96-AV | Single Phase Voltmeter Display: LED Input: AC 100V/220V/380V | /C: RS485 (Modbus-RTU) | 1. KC 2. CJM |
/M: 1 Analog Output (Programmable 4-20mA) | |||
/K: 2DI/2DO | |||
/J: Alarm | |||
AMC96L-AV | Single Phase Voltmeter Display: LCD Input: AC 100V/220V/380V | /C: RS485 (Modbus-RTU) | 1. KC 2. CJM |
/M: 1 Analog Output (Programmable 4-20mA) | |||
/K: 2DI/2DO | |||
/J: Alarm | |||
AMC96-AV3 | Single Phase Voltmeter Display: LED Input: AC 100V/220V/380V/660V | /C: RS485 (Modbus-RTU) | 1. KC 2. CJM 3. 3M+C |
/M: 1 Analog Output (Programmable 4-20mA) | |||
/K: 2DI/2DO | |||
/J: Alarm | |||
AMC96L-AV3 | Single Phase Voltmeter Display: LCD Input: AC 100V/220V/380V/660V | /C: RS485 (Modbus-RTU) | 1. KC 2. CJM 3. 3M+C |
/M: 1 Analog Output (Programmable 4-20mA) | |||
/K: 2DI/2DO | |||
/J: Alarm |