Refrigeration system: using imported Taikang compressors from France, high-efficiency and energy-saving ultra-low temperature refrigeration system from Europe and America (air-cooled cooling method);
Cold and hot exchange system: ultra-high efficiency SWEP refrigerant cold and hot exchange design (environmentally friendly refrigerant R404A);
Heating load regulation: Automatically adjust the refrigerant flow rate to effectively remove the heat dissipated by the heating load;
Condenser: finned attached heat dissipation motor;
Evaporator: Fin type multi-stage automatic load capacity adjustment;
Other accessories: desiccant, refrigerant flow window, repair valve;
Expansion system: a refrigeration system with capacity control.
Control system: Korean programmable imported TEM850 temperature controller
Introduction:
Original imported from South Korea, with LCD touch panel display in both Chinese and English, capable of inputting data in a face-to-face manner. Temperature and humidity can be programmed simultaneously. Backlight can be adjusted in 17 segments, with curve display and set value/display value curve. Multiple alarms can be displayed separately, and when a fault occurs, it can be displayed on the screen to eliminate the fault and eliminate misoperation. Multiple sets of PID control functions, precise monitoring functions, and displayed on the screen in the form of data.
Display: 320X240 dots, 30 lines of X40 characters LCD display screen
Accuracy: Temperature 0.01 ºC+1 digit, humidity 1% RH+1 digit
Resolution: Temperature 0.01, humidity 0.1% R.H
Temperature slope: 0.1-9.9 can be set
Temperature and humidity input signal: PT100 Ω X 2 (dry and wet bulb)
Temperature conversion output: -100-200 ºC relative to 1-2V
Humidity conversion output: 0-100% RH relative to 0-1V
P I. D control output: temperature 1 group, humidity 1 group
Data memory storage EEPROM (can be stored for more than 10 years)
Screen display function:
Face to face conversational data input with direct touch options on the screen
Display temperature and humidity settings (SV) and actual (PV) values directly (in both Chinese and English)
Can display the current execution program number, segment, remaining time, and number of cycles
Operation cumulative time function
Temperature and humidity program settings are displayed in graphical curves, with real-time display of program curve execution function
With a separate program editing screen, directly input temperature, humidity, and time
9 sets of P with upper and lower limit standby and alarm functions I. D parameter setting, P.I.D automatic calculation, dry and wet bulb automatic correction
Program capacity and control functions:
Available program groups: 10 groups
Number of available program segments: a total of 120 segments
Repeatable commands: Each command can be executed up to 999 times
The program is created in a conversational manner and has functions such as editing, clearing, and inserting
Program period time setting from 0 to 99Hour59Min
Capable of power-off program memory, automatically starting and continuing program execution after power restoration
Real time display of graphical curves during program execution
Equipped with date and time adjustment, appointment start, shutdown function, and screen lock (LOCK) function