Xhgx507 Manufacturing Factory Underground Cable Route Tracer Metal Detector Cable Fault Locator Testing Instrument

Min.Order: 1
Product origin: Xi'an, Shaanxi, China
Infringement complaint: complaintComplaint
US$ 2000 ~ 3000

Description

 


Product Description

 

Our company has long been committed to the research of cable fault testing. The cable fault intelligent tester has been used by thousands of users and has a high reputation in the field of power cable testing. The XHGX507 cable fault comprehensive tester developed by the company using the latest concept is especially suitable for fast and accurate positioning of cable-to-ground insulation faults, (live) path finding, cable identification, and deep positioning.

The XHGX507 cable fault comprehensive tester is designed based on the electromagnetic induction method and the application of the communication principle. Contains more user-friendly design in use. The large-screen LCD displays the signal strength, and the bars, arrows and voice prompts make it easy for the operator to determine the location of the cable underground and the point of failure. One person can complete all operations.

XHGX507 cable fault comprehensive tester can be used to find the cable (live or uncharged) path and identification, but also can be used to find the direct buried cable fault. It can complete tasks that were only possible with the past few sets of instruments.

The XHGX507 cable fault comprehensive tester changes the traditional cable fault location concept. It does not require high-voltage test equipment, AC power supply, and waveform analysis. The wiring is simple and clear, and the method of use is easy to learn. In the past, when we searched for the cable path and identified the cable, it was necessary to test the power failure of the cable, and some running cables could not be powered off, so that it can easily solve the problem of finding and identifying the path of the live cable. It can also directly find the path and identification of 50Hz live cables.

  1. All-digital locator, clear display and reliable positioning
  2. Portable and lightweight, easy to use, quick to find
  3. Built-in rechargeable battery, no utility power is needed for testing
  4. With cable buried depth display, current display
  5. Large-screen LCD graphic display, no earphones required during testing
  6. Built-in ohmmeter can measure cable loop resistance
  7. With two functions of cable location and fault finding
  8. Insulation faults to ground up to 2MΩ can be found
  9. With backlight function to adapt to night operation

Technical Parameters
 
Transmitter 
Working frequencylow frequency (815Hz), intermediate frequency (8kHz), high frequency (33 kHz), radio frequency (83 kHz)
 
Working modedirect connection method, coupling method (caliper method), induction method
 
Matching load5 ohms-3000 ohms
Impedance display5 digits
Overheating and over currentautomatic protection
Power outputlow gear, middle gear, high gear
 
Receiver 
Working frequencylow frequency (815Hz), intermediate frequency (8kHz), high frequency (33 kHz), radio frequency (83 kHz),  Passive frequency 50Hz
Antenna modevalley method (zero value mode), crest method (peak mode), step voltage method and clamp current method (A-frame)
Current indicationdisplay the effective current value of the cable under test (unit: mA)
Working temperature-10ºC+55ºC
Power indicatorgraphic display
Battery lifecontinuous work> 8 hours: intermittent work> 16 hours
Signal strength indicationladder diagram, digital range 0-999
Gain controlmanual adjustment, dynamic range of 100dB
Detection depththe maximum detection depth is not less than 5 meters
Maximum detection distanceThe cable with good insulation can be up to 15km in the direct connection method
Depth measurementpress the depth key to display three digits, the maximum depth can be measured up to 10 meters
AccuracyLow frequency: ±(1-5)%≤2.5m Radio frequency: ±(5-12)%≤2.5m
 
 

 

 

Product Parameters

 Antenna pattern
the trough method (vertical coil), the peak method (horizontal coil)
 Sound indication
signal intensity changes with the FM tone
 Current indication
Display the current value of the effective cable under test (unit: mA)
 Operating temperature
-10 ° C - +55 ° C
 Battery Type
7.4V lithium battery
 Battery indicator
graphics
 Battery life
continuous > 8 hours: stopped working > 16 hours
 Size
70cm × 20cm × 11cm
 Weight
3 kg (with battery)
 Signal strength, said
ladder, the number range 0 - 999
 Gain Control
manually adjust the dynamic range of 100db
 Detection depth
Maximum depth of not less than 2.5m probe
 Maximum detection range
direct law insulated cable up to 15km
 Depth measurement
according to the depth of three key figures, the maximum depth can be measured up to 2.5 m
 Accuracy
 LF: ± (1-5)% ≤ 2 5 meter RF: ± (5-12)% ≤ 2 5 meter
 Operating frequency
low frequency, RF
 Mode
direct method, coupling method, inductive method
 Matched load
5 ohms -3000 ohms
 Impedance display
five digits
 Thermal over-current
automatic protection
 Power output/low block,
high gear / mid-range,
 Battery Type
7.4V lithium battery
 Battery life
 working 4-8 hours depending on use frequency, output power
 Intermittent work
 6-10 hours depending on the frequency of use, output power
 Operating temperature
-10 ° C-55 ° C
 Dimensions
16cm × 16cm × 39cm

Product Tag:
Related categories:
Scroll to Top