The compact CPU 1215C has:
Device versions | ||||
---|---|---|---|---|
Option | Supply voltage | Input voltage DI | Output voltage DO | Output current |
| 24 V DC | 24 V DC | 24 V DC | 0.5 A, transistor |
| 24 V DC | 24 V DC | 5 … 30 V DC / | 2 A; |
| 85 … 264 V AC | 24 V DC | 5 … 30 V DC / | 2 A; |
SIMATIC S7-1200, CPU 1215C, compact CPU, AC/DC/relay, 2 PROFINET ports, onboard I/O: 14 DI 24 V DC; 10 DO relay 2 A, 2 AI 0-10 V DC, 2 AO 0-20 mA DC, Power supply: AC 85-264 V AC at 47-63 Hz, Program/data memory 125 KB | |||
General information | |||
Product type designation | CPU 1215C AC/DC/relay | ||
Firmware version | V4.5 | ||
Engineering with | |||
| STEP 7 V17 or higher | ||
Supply voltage | |||
Rated value (AC) | |||
| Yes | ||
| Yes | ||
permissible range, lower limit (AC) | 85 V | ||
permissible range, upper limit (AC) | 265 V | ||
Line frequency | |||
| 47 Hz | ||
| 63 Hz | ||
Input current | |||
Current consumption (rated value) | 100 mA at 120 V AC; 50 mA at 240 V AC | ||
Current consumption, max. | 300 mA at 120 V AC; 150 mA at 240 V AC | ||
Inrush current, max. | 20 A; at 264 V | ||
I²t | 0.8 A²·s | ||
Output current | |||
for backplane bus (5 V DC), max. | 1 600 mA; Max. 5 V DC for SM and CM | ||
Encoder supply | |||
24 V encoder supply | |||
| 20.4 to 28.8V | ||
Power loss | |||
Power loss, typ. | 14 W | ||
Memory | |||
Work memory | |||
| 125 kbyte | ||
| No | ||
Load memory | |||
| 4 Mbyte | ||
| with SIMATIC memory card | ||
Backup | |||
| Yes | ||
| Yes | ||
| Yes | ||
CPU processing times | |||
for bit operations, typ. | 0.08 µs; / instruction |
for word operations, typ. | 1.7 µs; / instruction 2.3 µs; / instruction |
for floating point arithmetic, typ. | |
CPU-blocks | |
Number of blocks (total) | DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used |
OB | |
| Limited only by RAM for code |
Data areas and their retentivity | |
Retentive data area (incl. timers, counters, flags), max. | 14 kbyte |
Flag | |
| 8 kbyte; Size of bit memory address area |
Local data | |
| 16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB |
Address area | |
Process image | |
| 1 kbyte 1 kbyte |
Hardware configuration | |
Number of modules per system, max. | 3 comm. modules, 1 signal board, 8 signal modules |
Time of day | |
Clock | |
| Yes 480 h; Typical ±60 s/month at 25 °C |
Digital inputs | |
Number of digital inputs
| 14; Integrated 6; HSC (High Speed Counting) Yes |
Source/sink input | |
Number of simultaneously controllable inputs | |
all mounting positions | |
- up to 40 °C, max. | 14 |
Input voltage | |
| 24 V 5 V DC at 1 mA 15 V DC at 2.5 mA |
Input delay (for rated value of input voltage) | |
for standard inputs | |
- parameterizable - at "0" to "1", min. - at "0" to "1", max. | Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four 0.2 ms 12.8 ms |
for interrupt inputs | |
- parameterizable | Yes |
for technological functions | |
- parameterizable | Single phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3 @ 30 kHz |
Cable length | |
| 500 m; 50 m for technological functions 300 m; for technological functions: No |
Digital outputs | |
Number of digital outputs | 10; Relays |
Switching capacity of the outputs | |
| 2 A 30 W with DC, 200 W with AC |
Output delay with resistive load | |
| 10 ms; max. 10 ms; max. |
Relay outputs |
| 10 mechanically 10 million, at rated load voltage 100 000 |
Cable length | |
| 500 m 150 m |
Analog inputs | |
Number of analog inputs | 2 |
Input ranges | |
| Yes |
Input ranges (rated values), voltages | |
| Yes ≥100k ohms |
Cable length | |
| 100 m; twisted and shielded |
Analog outputs | |
Number of analog outputs | 2 |
Output ranges, current | |
| Yes |
Analog value generation for the inputs | |
Integration and conversion time/resolution per channel | |
| 10 bit Yes 625 µs |
Encoder | |
Connectable encoders | |
| Yes |
1. Interface | |
Interface type | PROFINET |
Isolated | Yes |
automatic detection of transmission rate | Yes |
Autonegotiation | Yes |
Autocrossing | Yes |
Interface types | |
| Yes 2 Yes |
Protocols | |
| Yes |
| Yes |
| Yes |
| Yes; Optionally also encrypted |
| Yes |
| Yes |
PROFINET IO Controller | |
| 100 Mbit/s |
Services | |
- PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
- Isochronous mode | No |
- IRT | No |
- PROFIenergy | No |
- Prioritized startup | Yes |
- Number of IO devices with prioritized startup, | 16 |
max. | |
- Number of connectable IO Devices, max. | 16 |
- Number of connectable IO Devices for RT, | 16 |
max. | |
- of which in line, max. | 16 |
- Activation/deactivation of IO Devices | Yes |
- Number of IO Devices that can be | 8 |
simultaneously activated/deactivated, max. |