Ce Approved Aj-2102 Anesthesia Machine with Ventilator

Min.Order: 1
Product origin: Anqing, Anhui, China
Infringement complaint: complaintComplaint
US$ -1

Description
Anesthesia Machine with Ventilator AJ-2102


TECHNICAL PARAMETERS

Part of Anesthesia Machine
*Main body  High-strength engineering plastic rack, light,
beautiful and corrosion resistant
*Scope of application   adult, child
*Gas source   O2: 0.27~0.55MPa  N2O: 0.27~0.55MPa
*Flow meter  O2: 0.1~10L/min   N2O: 0.1~10L/min
*O2, N2O linkage and N2O Stopper
 When using nitrous oxide, oxygen concentration>25%;
 When the oxygen pressure<0.2MPa, the flow of nitrous oxide would be cut off.
*Flow rate of rapid oxygen supply  25~75L/min
*Low oxygen pressure alarm    There will be sound alarm when the oxygen pressure < 0.2MPa
*Vaporizer  it has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%. Among Halothane, Enflurane, Isoflurane and Sevoflurane, one can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available.
*Respiratory circuit  working mode: all-close, semi-close, semi-open
  releasing pressure: 0.5~7 kPa
*Respiratory bellows bellows for adults, bellows for children
tidal volume range:0~1,500 ml
 
Part of Ventilator
*Display mode  High-definition 5.7" LCD screen display
*Ventilation mode  IPPV,SIPPV,SIMV,PEE,MANUAL,SIGH
*Ventilation parameters 
Tidal volume  50~1500ml
Rate  2~99bmp
SIMV rate  2~20bpm
I:E  2:1~1:8
Inspiratory trigger pressure -1.0~2.0 kPa
PEEP  0~2.0 kPa
Pressure range   1.0~6.0 kPa
SIGH  1.5 times the inspiratory time

*Parameters for ventilation monitoring  tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure
*Monitoring of oxygen concentration  (21%~100%)
*Security Alarm System
Oxygen Concentration alarm   upper limit setting range (50%~100%)
low limit setting range  (15%~50%)
Airway pressure alarm  upper limit setting range  1.0~6.0 kPa
low limit setting range  0.4~2.0 kPa
Per-minute ventilation volume alarm  upper limit setting range  3.0~30L/min
low limit setting range  1.0~10L/min
Sustained high-pressure alarm    it will give alarm when stress have consistently
been higher than 2.5 kPa
Suffocation alarm  it will give sound and light alarm if there is
no tidal volume input for 15 seconds
Power alarm
*Power   AC 220V±10%     50Hz±1Hz
(UPS, Storage battery)
*Items within brackets are optional.