15 Mva 20 Mva 40mva 110V 220V High Voltage Power Transformer Price

Min.Order: 1
Product origin: Nantong, Jiangsu, China
Infringement complaint: complaintComplaint
US$ 125000 ~ 298000

Description

Power Transformer

Power transformers are a core component of power transmission system. The substation transformer used for power transmission and transformation in a unit or substation, and is also the core part of the substation. Transformers are the core equipment of the traction power supply system of electric locomotives, and also the key equipment to ensure the safe and stable operation of the traction power supply system.
 

 

Product Description

Design and Manufacture Standard ANSI-IEEE 57. 12/CSA/EN/BS/GOST/AS,IEC 600761

 

Design

Sealed-tank system /Inert-gas pressure system or Conservator-tank system without diaphragm

On load or no load voltage tap changer

 

ONAN/ONAF/ODAF/OFAF/OFWF/KNAN/KNAF

 

Insulation

 

Mineral Oil Inhibited I Not Inhibited I Vegetable oil

 

Primary voltage

 

Up to 230kv, up to 900kv BIL

 

Capacity

 

Up to 240MVA

 

Frequency

 

50/60 HZ


Operating Condition

Suitable for indoor and outdoor application.
Ambient temperature:-50 ºC~40 ºC
Relative humidity:ambient air relative humidity should be below93%,
Altitude:≤1000m
Max wind speed:≤35 m/s
Earthquake acceleration:horizontal acceleration ≤0.3g    
vertical acceleration≤0. 15g
Special conditions:customized products are available.

STANDARD FEATURES
Capacity range:Through 60 MVA (ONAN), with high-voltage  
ratings through 230 kV (900 kV BIL)
Service Location: Outdoor
Core: Regular grain-oriented; mitered cruciform with step-lap  construction
Coils: Cylindrical construction; all copper windings, custom tempered per design requirements; circular windings with rectangular or continuously-transposed conductor; helical low-voltage  windings;  continuous disc medium-voltage windings; shielded disc high-vollage windings
Radiators: Detachable panel type with shut-off valves; mild steel
Insulating oil: mineral oil type  I & typell
Tank  Cover.Welded,  
Bolted Manholes: On cover or tank
Tank Base: Flat bottom or Skid under base
Tank  Material:  Mid  Steel
Frequency:  60  Hertz Winding  
Tem  rise:  55 ºC
HV Taps; DETC, ETC in tank or out
- Above rated volts: 2 x2- 1/2% off load taps of full capacity    
-Below rated volts: 2 x 2- 1/2% off load laps of full capacity
Valve: Drain and Fiter Valves, w/Sampler                                
Lifting, Moving, and Jacking Facilities

Technical Data

Technical Data for 69KV Class Three Phase Two Winding OLTC Power Transformer
(KVA)
Rated Power 
(KV)
High Voltage
(KV)
Low Voltage
Connection SymbolShort Circuit
Impendence (%)
No-load Loss (KW)On-load Loss (KW)No load Current (%)
10000696.3
6.6
10.5
11
YNd11912.147.60.75
1200012.656.50.53
1500015.169.50.49
2000017.984.20.49
2500021.199.50.42
3000025.11200.42
3750030140.30.39
5000035.4174.30.39
6000042.12100.39

Technical Data for 69KV Class Three Phase Two Winding NLTC Power Transformer
(KVA)
Rated Power 
(KV)
High Voltage
(KV)
Low Voltage
Connection SymbolShort Circuit
Impendence (%)
No-load Loss (KW)On-load Loss (KW)No load Current (%)
10000696.3
6.6
10.5
11
YNd11911.647.60.75
1200013.656.50.53
1500016.369.50.49
2000019.284.20.49
2500022.699.50.42
3000026.81200.42
3750031.9140.30.39
5000038.6174.30.39
6000044.42100.39

Technical Data for 115KV Class Three Phase Two Winding OLTC Power Transformer 
(KVA)
Rated Power 
(KV)
High Voltage
(KV)
Low Voltage
Connection SymbolShort Circuit
Impendence (%)
No-load Loss (KW)On-load Loss (KW)No load Current (%)
10000115
138
161
6.3
6.6
10.5
11
YNd1110.511.851.20.82
1200013.759.50.82
1500016.373.10.76
2000019.588.40.76
2500022.71050.69
3000027.41260.69
3750032.91480.63
5000038.91840.63
6000046.42210.57

Technical Data for 115KV Class Three Phase Two Winding NLTC Power Transformer 
(KVA)
Rated Power 
(KV)
High Voltage
(KV)
Low Voltage
Connection SymbolShort Circuit
Impendence (%)
No-load Loss (KW)On-load Loss (KW)No load Current (%)
10000115
138
161
6.3
6.6
10.5
11
YNd1110.510.550.20.64
1200012.459.50.64
150001573.10.59
2000017.888.40.59
25000211050.54
30000251260.54
3750029.91480.56
5000035.3178.50.52
6000041.92210.48

Technical Data for 230KV Class Three Phase Two Winding OLTC Power Transformer 
(KVA)
Rated Power 
(KV)
High Voltage
(KV)
Low Voltage
Connection SymbolShort Circuit
Impendence (%)
No-load Loss (KW)On-load Loss (KW)No load Current (%)
300002306.3
6.6
10.5
11
34.5
66
YNd1112301280.69
37500361490.63
50000431800.63
60000502090.57

Technical Data for 230KV Class Three Phase Two Winding NLTC Power Transformer 
(KVA)
Rated Power 
(KV)
High Voltage
(KV)
Low Voltage
Connection SymbolShort Circuit
Impendence (%)
No-load Loss (KW)On-load Loss (KW)No load Current (%)
300002306.3
6.6
10.5
11
34.5
66
YNd1112281280.7
37500331490.7
50000391800.65
60000462090.65

Transformer Test
Winding   resistanceWinding insulation resistance
Core insulation resistanceRatio
Polarity and phase relationInsulation power factor
Control(auxiliary) cooling lossesSingle-phase excitation tests
Noload losses and excitation currentImpedance voltage and  load  losses
Zero-phase  sequence   impedance  voltageTemperature   rise
Low frequency dielectric testsLow frequency dielectric tests on axiliary devices
control, and current transformer circuitsLightning  impulse
Front of wave impulseSwithing   impulse
Partial dischargeAudible  sound  level
Operational tests (all devices)Dissolved gases in oil
Leak  test 
 

Sales Record

Daelim's transformers are sold to nearly 100 countries including the United States, Canada, Mexico, Ecuador, Chile, and Australia. The picture below is part of the sales record.
 


DAELIM BELEFIC

Daelim Belefic builds power translormers that deliver power to the consumer efficiently and reliably.

Our single-phase and three-phase winding or autotransformer are according to international standards such as ANSI/IEEE/IEC/CSA/AS as well as NEMA standards, etc, the power ratings are up to 270 MVA and for vollages up to the highest insulation class of 900 kV.

 

Daelim's transformers have been exported to America, Canada, Mexico, Australia, Chile, Ecuador, Venezuela, Honduras, El Salvador, Panama and other countries. DAELIM have helped many international customers to successfully obtain transformer projects and continue to carry out in-depth cooperation.

DAELIM have 20 years of transformer export experience, moreover DAELIM have after-sales installation teams overseas, so if you also have transformer business, we can develop together.

Daelim Transformer High Quality Service

a.pre-sales


Daelim has a very serious quality control system, strictly controlling every detail from transformer design to raw material procurement, assembly, testing, packaging and delivery.

b.after sales

1.Up to 24 months quality guarantee period. If there is any problem in the operation of your transformer, Daelim's after-sales team will solve it promptly and quickly;

2.Local after-sales installation service team. Whether you are in North America, South America or other regions, Daelim's local team can provide you with professional transformer installation, commissioning, maintenance and other services;

3.Daelim provides remote video guidance for transformer installation.



Thank you for reading. If you need inquiries, please contact us.
Product Tag:
Related categories:
Scroll to Top