22kv Sf6 Gas Inssulated Sm6 RM6 Load Break Switch/ Lbs Breaker/Arrester/Load Break Switch Ring Main Unit Switchgear Sf6 Gas Insulated Lbs Breaker

Min.Order: 1
Product origin: Wenzhou, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 235 ~ 1800

Description
 
Product Description
 

FL(R)N36-12(D) Load switches and combiners (hereinafter referred to as "load switches" and "combiners") are suitable for three-phase ac power systems of 10kV and 50Hz
This product as industrial and mining enterprises, high-rise buildings, residential quarters, pre-installed type substation, for the breaking, closing load current, the fault current, control and protection circuit and the power distribution transformer

1.normal operating conditions

a)Ambient air temperature is not more than 40 ºC, and at 24 h closed to the average no more than 35 ºC. Minimum ambient air temperature 25 ºC.
b)The effects of sunlight can be ignored
c)No more than 3000m above sea level.
d)Ambient air is not significantly contaminated by dust, smoke, corrosive and/or flammable gases, vapors, or salt fog. If the user does not have special requirements, the manufacturer may consider that these situations do not exist.e)The humidity conditions are as follows:
--The average relative humidity measured within 24h is no more than 95%.
--The mean value of water vapor pressure measured within 24h shall not exceed 2.2kPa.
--The average monthly relative humidity should not exceed 90%.
--The average monthly water vapor pressure does not exceed 1.8kpa. In such conditions appear condensation occasionally.
f) The vibration or ground motion from the outside of the switching equipment and the control equipment has no obvious relationship with the normal operation mode of the equipment. If the user has no special requirements, the manufacturer may not consider these situations.

GB 3804-2004        3.6KV~40.5KVHigh voltage ac load switch
GB 16926-2009       High voltage ac load switch fuse combination electrical appliance
GB 11023-1989       Test guide for fln36 gas seal of high pressure switching equipment
GB 1985-2004        High voltage ac isolation switch and ground switch
GB/T 11022-2011 Common technical requirements for high voltage switching equipment and control equipment standards

Product Parameters

 

No.
  •    Description
UnitData
FLN36-12FLN36-12D
1
  • Rated Voltage
kV12
2
  • Rated Current
A630125
3Load switch rated short - term withstand current/durationkA/s20/3
Ground switch rated short - term withstand current/durationkA/s20/2
4Rated peak withstand current and short circuit closing currentkA50125(Expect)
5Rated active load switching currentA630
6Rated closed loop breaking currentA630
75% rated active load open currentA31.5
8Rated cable charging currentA10
9Rated capacity of open - break no-load transformerkVA1250
10Rated transfer open currentA 1700
11Rated expected short circuit open currentkA 50
12Rated insulation level  
 1min working frequency withstand voltage phase to ground/breakkV42/48
Lightning shock withstand voltage alternate, ground - to - ground/breakkV75/85
13
Mechanical endurance
 5000
14SF6 pressure rating (20 ºC)MPa0.04 ~0.05
15Rated operating voltage of electric mechanismVAC/DC220
16Power frequency withstand voltage of secondary line 1minV2000
17Air leak rate/Year<0.5%

 